Peter Wiegand
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peter Wiegand has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Céline M. Pfeifer
Institute of Legal Medicine, Albert-Einstein-Allee 23, 89081, Ulm, Germany.
3 shared publications E. Miltner
Institut für Rechtsmedizin, Universitätsklinikum Ulm, Ulm, Deutschland
2 shared publications- Hannah Holtkötter
Institute of Legal Medicine, University of Münster, Röntgenstraße 23, 48149, Münster, Germany.
2 shared publications - Kristina Schwender
Institute of Legal Medicine, University of Münster, Röntgenstraße 23, 48149, Münster, Germany
2 shared publications - Marielle Vennemann
Institute of Legal Medicine, University of Münster, Münster, Germany
2 shared publications - Max Schwender
Institute of Legal Medicine, University Ulm, Albert-Einstein-Allee 23, 89081 Ulm, Germany
2 shared publications
Latest Publications
- 1 January 2023
- Published by Springer Nature
- p. 13-21
Akkreditierung, Qualitätssicherung
- 1 March 2022
- Published by Elsevier in Forensic Science International: Genetics
- Vol. 57, 102648
Persistence of blood (DNA/RNA) on shoe soles under varying casework related conditions
- 1 March 2022
- Published by Elsevier in Forensic Science International: Genetics
- Vol. 57, 102648
Persistence of blood (DNA/RNA) on shoe soles under varying casework related conditions
- 1 November 2021
- Published by Elsevier in Forensic Science International: Genetics
- Vol. 55, 102570
Statistefix 4.0: A novel probabilistic software tool
- 1 November 2021
- Published by Elsevier in Forensic Science International: Genetics
- Vol. 55, 102570
Statistefix 4.0: A novel probabilistic software tool
- 29 October 2017
- Published by Springer Nature in International journal of legal medicine
- Vol. 132 (1) , 83-90
Improving body fluid identification in forensic trace evidence—construction of an immunochromatographic test array to rapidly detect up to five body fluids simultaneously
Body fluid identification is a substantial part of forensic trace analyses. The correct determination of the origin of a biological stain may give valuable information regarding the circumstances of a crime. A simple way to detect a body fluid in a stain is the use of immunochromatographic strip tests. They are easy to use, user-independent, quick, and cheap. Currently, however, it is only possible to analyze one body fluid at a time, requiring the analyst to make previous, possibly subjective, assumptions on the body fluid at hand. Also, identification of mixed body fluids requires the use of several tests, which results in additional sample and time consumption. To combine a simple approach with the possibility to simultaneously detect several body fluids, we constructed a combined immunochromatographic strip test array based on commercially available tests. The array rapidly detects up to five body fluids with a single analysis, and allowing for subsequent DNA extraction from the same material. With this test it was possible to identify the components of a mixture, the test was easily incorporated into standard laboratory work, and its sensitivity and specificity were shown to be comparable to those of conventional strip tests.
- 29 October 2017
- Published by Springer Nature in International journal of legal medicine
- Vol. 132 (1) , 83-90
Improving body fluid identification in forensic trace evidence—construction of an immunochromatographic test array to rapidly detect up to five body fluids simultaneously
Body fluid identification is a substantial part of forensic trace analyses. The correct determination of the origin of a biological stain may give valuable information regarding the circumstances of a crime. A simple way to detect a body fluid in a stain is the use of immunochromatographic strip tests. They are easy to use, user-independent, quick, and cheap. Currently, however, it is only possible to analyze one body fluid at a time, requiring the analyst to make previous, possibly subjective, assumptions on the body fluid at hand. Also, identification of mixed body fluids requires the use of several tests, which results in additional sample and time consumption. To combine a simple approach with the possibility to simultaneously detect several body fluids, we constructed a combined immunochromatographic strip test array based on commercially available tests. The array rapidly detects up to five body fluids with a single analysis, and allowing for subsequent DNA extraction from the same material. With this test it was possible to identify the components of a mixture, the test was easily incorporated into standard laboratory work, and its sensitivity and specificity were shown to be comparable to those of conventional strip tests.
- 1 July 2017
- Published by Elsevier in Forensic Science International: Genetics
- Vol. 29, 261-268
Independent validation of body fluid-specific CpG markers and construction of a robust multiplex assay
- 1 July 2017
- Published by Elsevier in Forensic Science International: Genetics
- Vol. 29, 261-268
Independent validation of body fluid-specific CpG markers and construction of a robust multiplex assay
- 26 June 2017
- Published by Springer Nature in International journal of legal medicine
- Vol. 131 (5) , 1221-1228
DNA persistence of bite marks on food and its relevance for STR typing
- 26 June 2017
- Published by Springer Nature in International journal of legal medicine
- Vol. 131 (5) , 1221-1228
DNA persistence of bite marks on food and its relevance for STR typing
- 3 August 2016
- Published by Springer Nature in Rechtsmedizin
- Vol. 26 (5) , 453-470
Analyse von Hautkontaktspuren in der forensischen Genetik unter besonderer Berücksichtigung ihrer Entstehung und Spurenentnahme
- 3 August 2016
- Published by Springer Nature in Rechtsmedizin
- Vol. 26 (5) , 453-470
Analyse von Hautkontaktspuren in der forensischen Genetik unter besonderer Berücksichtigung ihrer Entstehung und Spurenentnahme
- 3 August 2016
- Published by Springer Nature in Rechtsmedizin
- Vol. 26 (6) , 537-552
Analyse von Hautkontaktspuren in der forensischen Genetik unter besonderer Berücksichtigung von Kontamination und Transferszenarien
- 3 August 2016
- Published by Springer Nature in Rechtsmedizin
- Vol. 26 (6) , 537-552
Analyse von Hautkontaktspuren in der forensischen Genetik unter besonderer Berücksichtigung von Kontamination und Transferszenarien
- 22 January 2011
- Published by Springer Nature in International journal of legal medicine
- Vol. 125 (4) , 543-548
Hot flakes in cold cases
In the past, it was almost impossible for forensic scientists to separate DNA from an undefined number of different individuals in mixed stains where, for example, two or more suspects had handled the same weapon. Such samples often contain complex mixtures with the consequence of ambiguous or inconclusive mixed DNA profiles. Using the method described of comprehensive and/or targeted screening of shed cells adhering to tapings of garments or objects enables such stains to be individualized. To evaluate the method, 500 microscopically selected single skin flakes were analyzed using two different commercial STR kits to compare the success rates for each PCR typing system. The method has been validated for use in routine casework and has been shown to be rapid, sensitive, and reproducible. It can be predicted that many cases in the archives with body tapings, which have not yet been examined will benefit from this new or perhaps more appropriate, reanimated, technical development, and of particular importance are serious crimes, the so-called cold cases. The remarkable forensic value of this simple but time-consuming technique is exemplified by 2 out of approximately 100 cases already successfully solved using this approach.
- 22 January 2011
- Published by Springer Nature in International journal of legal medicine
- Vol. 125 (4) , 543-548
Hot flakes in cold cases
In the past, it was almost impossible for forensic scientists to separate DNA from an undefined number of different individuals in mixed stains where, for example, two or more suspects had handled the same weapon. Such samples often contain complex mixtures with the consequence of ambiguous or inconclusive mixed DNA profiles. Using the method described of comprehensive and/or targeted screening of shed cells adhering to tapings of garments or objects enables such stains to be individualized. To evaluate the method, 500 microscopically selected single skin flakes were analyzed using two different commercial STR kits to compare the success rates for each PCR typing system. The method has been validated for use in routine casework and has been shown to be rapid, sensitive, and reproducible. It can be predicted that many cases in the archives with body tapings, which have not yet been examined will benefit from this new or perhaps more appropriate, reanimated, technical development, and of particular importance are serious crimes, the so-called cold cases. The remarkable forensic value of this simple but time-consuming technique is exemplified by 2 out of approximately 100 cases already successfully solved using this approach.
- 2 March 2010
- Published by Springer Nature in International journal of legal medicine
- Vol. 125 (5) , 727-731
Transfer of biological stains from different surfaces
Highly sensitive short tandem repeat-based stain analysis of weak biological stains has been improved during the last years. The risk of transfer of cellular material from handled items contaminated with biological stains such as blood and saliva is of forensic relevance. Although the policemen working with crime scene items are very careful, there exists a potential risk of transfer contamination. To obtain estimates for the risk of stain transfer by handling, we have carried out an experimental study on 288 dried blood and saliva stains in two laboratories. DNA quantification showed only small amounts of DNA that could be transferred, especially from stains on paper and cotton. The saliva and especially the blood stains from plastic surface resulted in higher amounts of transferred DNA, depending on the relation of blood volume to included area: Of 192 direct transfers, 17% gave extracts above 10 pg DNA/μl, and only 3% of 96 secondary transfers resulted in amounts above 10 pg DNA/μl.
- 2 March 2010
- Published by Springer Nature in International journal of legal medicine
- Vol. 125 (5) , 727-731
Transfer of biological stains from different surfaces
Highly sensitive short tandem repeat-based stain analysis of weak biological stains has been improved during the last years. The risk of transfer of cellular material from handled items contaminated with biological stains such as blood and saliva is of forensic relevance. Although the policemen working with crime scene items are very careful, there exists a potential risk of transfer contamination. To obtain estimates for the risk of stain transfer by handling, we have carried out an experimental study on 288 dried blood and saliva stains in two laboratories. DNA quantification showed only small amounts of DNA that could be transferred, especially from stains on paper and cotton. The saliva and especially the blood stains from plastic surface resulted in higher amounts of transferred DNA, depending on the relation of blood volume to included area: Of 192 direct transfers, 17% gave extracts above 10 pg DNA/μl, and only 3% of 96 secondary transfers resulted in amounts above 10 pg DNA/μl.