Maximilian F. Reiser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maximilian F. Reiser has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Clemens C. Cyran
Klinikum der Universität München – Campus Großhadern
6 shared publications - Tobias F. Jakobs
Department of Radiology, Krankenhaus Barmherzige Brüder München, München, Germany
6 shared publications - Konstantin Nikolaou
Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany
5 shared publications - Jochen Grimm
Department of Neuroradiology, Christian Doppler Medical Center, Paracelsus Medical University, Salzburg, Austria
4 shared publications - Andreas Schindler
Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Munich, Germany.
3 shared publications - Chun Yuan
Department of Radiology, University of Washington, Seattle, Washington
3 shared publications
Latest Publications
- Open Access
- 18 January 2018
- Published by Springer Nature in Cancer Imaging
- Vol. 18 (1) , 2
18F–FDG-PET/CT and diffusion-weighted MRI for monitoring a BRAF and CDK 4/6 inhibitor combination therapy in a murine model of human melanoma
The purpose of the study was to investigate a novel BRAF and CDK 4/6 inhibitor combination therapy in a murine model of BRAF-V600-mutant human melanoma monitored by 18F–FDG-PET/CT and diffusion-weighted MRI (DW-MRI). Human BRAF-V600-mutant melanoma (A375) xenograft-bearing balb/c nude mice (n = 21) were imaged by 18F–FDG-PET/CT and DW-MRI before (day 0) and after (day 7) a 1-week BRAF and CDK 4/6 inhibitor combination therapy (n = 12; dabrafenib, 20 mg/kg/d; ribociclib, 100 mg/kg/d) or placebo (n = 9). Animals were scanned on a small animal PET after intravenous administration of 20 MBq 18F–FDG. Tumor glucose uptake was calculated as the tumor-to-liver-ratio (TTL). Unenhanced CT data sets were subsequently acquired for anatomic coregistration. Tumor diffusivity was assessed by DW-MRI using the apparent diffusion coefficient (ADC). Anti-tumor therapy effects were assessed by ex vivo immunohistochemistry for validation purposes (microvascular density – CD31; tumor cell proliferation – Ki-67). Tumor glucose uptake was significantly suppressed under therapy (∆TTLTherapy − 1.00 ± 0.53 vs. ∆TTLControl 0.85 ± 1.21; p < 0.001). In addition, tumor diffusivity was significantly elevated following the BRAF and CDK 4/6 inhibitor combination therapy (∆ADCTherapy 0.12 ± 0.14 × 10−3 mm2/s; ∆ADCControl − 0.12 ± 0.06 × 10−3 mm2/s; p < 0.001). Immunohistochemistry revealed a significant suppression of microvascular density (CD31, 147 ± 48 vs. 287 ± 92; p = 0.001) and proliferation (Ki-67, 3718 ± 998 vs. 5389 ± 1332; p = 0.007) in the therapy compared to the control group. A novel BRAF and CDK 4/6 inhibitor combination therapy exhibited significant anti-angiogenic and anti-proliferative effects in experimental human melanomas, monitored by 18F–FDG-PET/CT and DW-MRI.
- 18 January 2018
- Published by Springer Nature in Cancer Imaging
- Vol. 18 (1) , 2
Open Access18F–FDG-PET/CT and diffusion-weighted MRI for monitoring a BRAF and CDK 4/6 inhibitor combination therapy in a murine model of human melanoma
The purpose of the study was to investigate a novel BRAF and CDK 4/6 inhibitor combination therapy in a murine model of BRAF-V600-mutant human melanoma monitored by 18F–FDG-PET/CT and diffusion-weighted MRI (DW-MRI). Human BRAF-V600-mutant melanoma (A375) xenograft-bearing balb/c nude mice (n = 21) were imaged by 18F–FDG-PET/CT and DW-MRI before (day 0) and after (day 7) a 1-week BRAF and CDK 4/6 inhibitor combination therapy (n = 12; dabrafenib, 20 mg/kg/d; ribociclib, 100 mg/kg/d) or placebo (n = 9). Animals were scanned on a small animal PET after intravenous administration of 20 MBq 18F–FDG. Tumor glucose uptake was calculated as the tumor-to-liver-ratio (TTL). Unenhanced CT data sets were subsequently acquired for anatomic coregistration. Tumor diffusivity was assessed by DW-MRI using the apparent diffusion coefficient (ADC). Anti-tumor therapy effects were assessed by ex vivo immunohistochemistry for validation purposes (microvascular density – CD31; tumor cell proliferation – Ki-67). Tumor glucose uptake was significantly suppressed under therapy (∆TTLTherapy − 1.00 ± 0.53 vs. ∆TTLControl 0.85 ± 1.21; p < 0.001). In addition, tumor diffusivity was significantly elevated following the BRAF and CDK 4/6 inhibitor combination therapy (∆ADCTherapy 0.12 ± 0.14 × 10−3 mm2/s; ∆ADCControl − 0.12 ± 0.06 × 10−3 mm2/s; p < 0.001). Immunohistochemistry revealed a significant suppression of microvascular density (CD31, 147 ± 48 vs. 287 ± 92; p = 0.001) and proliferation (Ki-67, 3718 ± 998 vs. 5389 ± 1332; p = 0.007) in the therapy compared to the control group. A novel BRAF and CDK 4/6 inhibitor combination therapy exhibited significant anti-angiogenic and anti-proliferative effects in experimental human melanomas, monitored by 18F–FDG-PET/CT and DW-MRI.
- Open Access
- 1 February 2017
- Published by Georg Thieme Verlag KG in Seminars in Musculoskeletal Radiology
- Vol. 21 (S 01) , S1-S5
Diagnostic Accuracy of Contemporary Multidetector Computed Tomography for the Detection of Lumbar Disk Herniation
Introduction: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of lumbar disk herniation with magnetic resonance imaging (MRI) as the standard of reference. Methods: Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered back projection (FBP). Lumbar spine MRI (1.5 T) was performed within 1 month. Signal-to-noise ratios (SNRs) of cerebrospinal fluid, annulus fibrosus, and the spinal cord were determined for all modalities. Two readers independently rated image quality (IQ), diagnostic confidence, and accuracy in the diagnosis of lumbar disk herniation using MRI as the standard of reference. Interreader correlation was assessed with weighted κ. Results: The percentages of sensitivity, specificity, precision, and accuracy of MDCT for disk protrusion were 98.8%, 96.5%, 97.1%, and 97.8% (disk level), and 97.7%, 92.9%, 98.6%, and 96.9% (patient level). SNR of IR was significantly higher than FBP. IQ was significantly better in IR owing to visually reduced noise and improved delineation of the disks. The κ (> 0.90) was excellent for both algorithms. Conclusion: MDCT of the lumbar spine yields high diagnostic accuracy for the detection of lumbar disk herniation. IR improves IQ so the provided diagnostic accuracy is principally equivalent to MRI.
- 1 February 2017
- Published by Georg Thieme Verlag KG in Seminars in Musculoskeletal Radiology
- Vol. 21 (S 01) , S1-S5
Open AccessDiagnostic Accuracy of Contemporary Multidetector Computed Tomography for the Detection of Lumbar Disk Herniation
Introduction: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of lumbar disk herniation with magnetic resonance imaging (MRI) as the standard of reference. Methods: Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered back projection (FBP). Lumbar spine MRI (1.5 T) was performed within 1 month. Signal-to-noise ratios (SNRs) of cerebrospinal fluid, annulus fibrosus, and the spinal cord were determined for all modalities. Two readers independently rated image quality (IQ), diagnostic confidence, and accuracy in the diagnosis of lumbar disk herniation using MRI as the standard of reference. Interreader correlation was assessed with weighted κ. Results: The percentages of sensitivity, specificity, precision, and accuracy of MDCT for disk protrusion were 98.8%, 96.5%, 97.1%, and 97.8% (disk level), and 97.7%, 92.9%, 98.6%, and 96.9% (patient level). SNR of IR was significantly higher than FBP. IQ was significantly better in IR owing to visually reduced noise and improved delineation of the disks. The κ (> 0.90) was excellent for both algorithms. Conclusion: MDCT of the lumbar spine yields high diagnostic accuracy for the detection of lumbar disk herniation. IR improves IQ so the provided diagnostic accuracy is principally equivalent to MRI.
- 1 March 2016
- Published by Elsevier in European Urology Supplements
- Vol. 15 (3) , e33
33 Performance of multi-frame shear-wave elastography in the diagnostic work-up of the scrotum
- 1 March 2016
- Published by Elsevier in European Urology Supplements
- Vol. 15 (3) , e33
33 Performance of multi-frame shear-wave elastography in the diagnostic work-up of the scrotum
- Open Access
- 8 May 2015
- Published by Springer Nature in BMC Cancer
- Vol. 15 (1) , 1-11
Reducing tumor growth and angiogenesis using a triple therapy measured with Contrast-enhanced ultrasound (CEUS)
To evaluate the in vivo response by detecting the anti-angiogenic and invasion-inhibiting effects of a triple-combination-therapy in an experimental-small-animal-squamous-cell-carcinoma-model using the “flash-replenishment” (FR) method to assess tissue hemodynamics via contrast-enhanced-ultrasound (CEUS). Human hypopharynx-carcinoma-cells were subcutaneously injected into the left flank of 22-female-athymic-nude-rats. After seven days of subcutaneous tumor growth, FR-measurements were performed on each rat. Treatment-group and control-group were treated every day for a period of one week, with the treatment-group receiving solvents containing a triple therapy of Upamostat®, Celecoxib® and Ilomastat® and the control-group solvents only. On day seven, follow-up measurements were performed using the same measurement protocol to assess the effects of the triple therapy. VueBox® was used to quantify the kinetic parameters and additional immunohistochemistry analyses were performed for comparison with and validation of the CEUS results against established methods (Proliferation/Ki-67, vascularization/CD31, apoptosis/caspase3). Compared to the control-group, the treatment-group that received the triple-therapy resulted in a reduction of tumor growth by 48.6% in size. Likewise, the immunohistochemistry results showed significant decreases in tumor proliferation and vascularization in the treatment-group in comparison to the control-group of 26%(p≤0.05) and 32.2%(p≤0.05) respectively. Correspondingly, between the baseline and follow-up measurements, the therapy-group was associated with a significant(p ≤ 0.01) decrease in the relative-Blood-Volume(rBV) in both the whole tumor(wt) and hypervascular tumor(ht) areas (p≤0.01), while the control-group was associated with a significant (p≤0.01) increase of the rBV in the wt area and a non-significant increase (p≤0.16) in the ht area. The mean-transit-time (mTT) of the wt and the ht areas showed a significant increase (p≤0.01) in the follow-up measurements in the therapy group. The triple-therapy is feasible and effective in reducing both tumor growth and vascularization. In particular, compared with the placebo-group, the triple-therapy-group resulted in a reduction in tumor growth of 48.6% in size when assessed by CEUS and a significant reduction in the number of vessels in the tumor of 32% as assessed by immunohistochemistry. As the immunohistochemistry supports the CEUS findings, CEUS using the “flash replenishment”(FR) method appears to provide a useful assessment of the anti-angiogenic and invasion-inhibiting effects of a triple combination therapy.
- 8 May 2015
- Published by Springer Nature in BMC Cancer
- Vol. 15 (1) , 1-11
Open AccessReducing tumor growth and angiogenesis using a triple therapy measured with Contrast-enhanced ultrasound (CEUS)
To evaluate the in vivo response by detecting the anti-angiogenic and invasion-inhibiting effects of a triple-combination-therapy in an experimental-small-animal-squamous-cell-carcinoma-model using the “flash-replenishment” (FR) method to assess tissue hemodynamics via contrast-enhanced-ultrasound (CEUS). Human hypopharynx-carcinoma-cells were subcutaneously injected into the left flank of 22-female-athymic-nude-rats. After seven days of subcutaneous tumor growth, FR-measurements were performed on each rat. Treatment-group and control-group were treated every day for a period of one week, with the treatment-group receiving solvents containing a triple therapy of Upamostat®, Celecoxib® and Ilomastat® and the control-group solvents only. On day seven, follow-up measurements were performed using the same measurement protocol to assess the effects of the triple therapy. VueBox® was used to quantify the kinetic parameters and additional immunohistochemistry analyses were performed for comparison with and validation of the CEUS results against established methods (Proliferation/Ki-67, vascularization/CD31, apoptosis/caspase3). Compared to the control-group, the treatment-group that received the triple-therapy resulted in a reduction of tumor growth by 48.6% in size. Likewise, the immunohistochemistry results showed significant decreases in tumor proliferation and vascularization in the treatment-group in comparison to the control-group of 26%(p≤0.05) and 32.2%(p≤0.05) respectively. Correspondingly, between the baseline and follow-up measurements, the therapy-group was associated with a significant(p ≤ 0.01) decrease in the relative-Blood-Volume(rBV) in both the whole tumor(wt) and hypervascular tumor(ht) areas (p≤0.01), while the control-group was associated with a significant (p≤0.01) increase of the rBV in the wt area and a non-significant increase (p≤0.16) in the ht area. The mean-transit-time (mTT) of the wt and the ht areas showed a significant increase (p≤0.01) in the follow-up measurements in the therapy group. The triple-therapy is feasible and effective in reducing both tumor growth and vascularization. In particular, compared with the placebo-group, the triple-therapy-group resulted in a reduction in tumor growth of 48.6% in size when assessed by CEUS and a significant reduction in the number of vessels in the tumor of 32% as assessed by immunohistochemistry. As the immunohistochemistry supports the CEUS findings, CEUS using the “flash replenishment”(FR) method appears to provide a useful assessment of the anti-angiogenic and invasion-inhibiting effects of a triple combination therapy.
- Open Access
- 1 December 2014
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 16 (1) , 84
Computed tomography angiography vs 3 T black-blood cardiovascular magnetic resonance for identification of symptomatic carotid plaques
- 1 December 2014
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 16 (1) , 84
Open AccessComputed tomography angiography vs 3 T black-blood cardiovascular magnetic resonance for identification of symptomatic carotid plaques
- Open Access
- 3 January 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 3
Visualization, imaging and new preclinical diagnostics in radiation oncology
Innovative strategies in cancer radiotherapy are stimulated by the growing knowledge on cellular and molecular tumor biology, tumor pathophysiology, and tumor microenvironment. In terms of tumor diagnostics and therapy monitoring, the reliable delineation of tumor boundaries and the assessment of tumor heterogeneity are increasingly complemented by the non-invasive characterization of functional and molecular processes, moving preclinical and clinical imaging from solely assessing tumor morphology towards the visualization of physiological and pathophysiological processes. Functional and molecular imaging techniques allow for the non-invasive characterization of tissues in vivo, using different modalities, including computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, positron emission tomography (PET) and optical imaging (OI). With novel therapeutic concepts combining optimized radiotherapy with molecularly targeted agents focusing on tumor cell proliferation, angiogenesis, and cell death, the non-invasive assessment of tumor microcirculation and tissue water diffusion, together with strategies for imaging the mechanisms of cellular injury and repair is of particular interest. Characterizing the tumor microenvironment prior to and in response to irradiation will help to optimize the outcome of radiotherapy. These novel concepts of personalized multi-modal cancer therapy require careful pre-treatment stratification as well as a timely and efficient therapy monitoring to maximize patient benefit on an individual basis. Functional and molecular imaging techniques are key in this regard to open novel opportunities for exploring and understanding the underlying mechanisms with the perspective to optimize therapeutic concepts and translate them into a personalized form of radiotherapy in the near future.
- 3 January 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 3
Open AccessVisualization, imaging and new preclinical diagnostics in radiation oncology
Innovative strategies in cancer radiotherapy are stimulated by the growing knowledge on cellular and molecular tumor biology, tumor pathophysiology, and tumor microenvironment. In terms of tumor diagnostics and therapy monitoring, the reliable delineation of tumor boundaries and the assessment of tumor heterogeneity are increasingly complemented by the non-invasive characterization of functional and molecular processes, moving preclinical and clinical imaging from solely assessing tumor morphology towards the visualization of physiological and pathophysiological processes. Functional and molecular imaging techniques allow for the non-invasive characterization of tissues in vivo, using different modalities, including computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, positron emission tomography (PET) and optical imaging (OI). With novel therapeutic concepts combining optimized radiotherapy with molecularly targeted agents focusing on tumor cell proliferation, angiogenesis, and cell death, the non-invasive assessment of tumor microcirculation and tissue water diffusion, together with strategies for imaging the mechanisms of cellular injury and repair is of particular interest. Characterizing the tumor microenvironment prior to and in response to irradiation will help to optimize the outcome of radiotherapy. These novel concepts of personalized multi-modal cancer therapy require careful pre-treatment stratification as well as a timely and efficient therapy monitoring to maximize patient benefit on an individual basis. Functional and molecular imaging techniques are key in this regard to open novel opportunities for exploring and understanding the underlying mechanisms with the perspective to optimize therapeutic concepts and translate them into a personalized form of radiotherapy in the near future.
- 2 March 2013
- Published by Springer Nature in Der Radiologe
- Vol. 53 (3) , 200-208
MR-gesteuerter fokussierter Ultraschall
- 2 March 2013
- Published by Springer Nature in Der Radiologe
- Vol. 53 (3) , 200-208
MR-gesteuerter fokussierter Ultraschall
- Open Access
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 44
Comparison of symptomatic and asymptomatic atherosclerotic carotid plaques using parallel imaging and 3 T black-blood in vivo CMR
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 44
Open AccessComparison of symptomatic and asymptomatic atherosclerotic carotid plaques using parallel imaging and 3 T black-blood in vivo CMR
- 1 April 2012
- Vol. 53 (2) , 247-55
Dual-Source computed tomography of the chest in the surgical planning of repeated cardiac surgery.
When reoperative cardiac surgery is indicated, detailed, three-dimensional imaging of the thorax permits accurate depiction of cardiac anatomy and vascular structures potentially increasing the safety of the surgical procedure. We sought to evaluate the contribution of dual-source multidetector-row computed tomography (DSCT) of the heart and thorax in planning repeated open heart surgery. Twenty-eight patients (mean age, 68 years) scheduled for repeated cardiac surgery who had undergone previous coronary artery bypass grafting (n=19) or cardiac valve replacement (8) or combined valvular and bypass surgery (1) underwent contrast-enhanced ECG-gated DSCT (Somatom Definition, Siemens Medical Solutions) of the whole thorax with a temporal resolution of 82 ms and a spatial resolution of 0.4 mm³. The indication for repeated surgery was bypass surgery (N.=6), valve replacement (16), combined bypass and valvular surgery (5) or other reasons (1). Assessment of surgical risk based on DSCT data were performed in terms of the relation of the ascending aorta and cardiac structures to the expected median sternotomy line, graft patency and anatomic course, and the degree of calcification of the ascending aorta and coronary arteries. DSCT findings led to a change of surgical approach for 9/28 (32.1%) patients (non-midline incision, N.=3; surgery performed under circulatory arrest, N.=5; peripheral arterial cannulation before sternotomy, N.=1) and cancellation of surgery for 4/28 (14.3%) patients (heavy aortic and coronary calcifications impeding bypass surgery, N.=2; right heart or aortic aneurysm in close proximity to the sternum in high risk patients, N.=2). The planned surgical approach remained unchanged after DSCT for the remaining15/28 (53.6%) patients. Of 54 bypass graft conduits (20 arterial, 34 venous) visualized on DSCT in 20 patients after previous bypass grafting, 16 arterial and 24 venous grafts were patent, while 4 arterial and 10 venous grafts were occluded. DSCT of the heart and thorax is an effective, non-invasive tool for the preoperative planning of repeated cardiac surgery. The technique provides significant information to modify the surgical approach and may increase the safety of the procedure.
- 1 April 2012
- Vol. 53 (2) , 247-55
Dual-Source computed tomography of the chest in the surgical planning of repeated cardiac surgery.
When reoperative cardiac surgery is indicated, detailed, three-dimensional imaging of the thorax permits accurate depiction of cardiac anatomy and vascular structures potentially increasing the safety of the surgical procedure. We sought to evaluate the contribution of dual-source multidetector-row computed tomography (DSCT) of the heart and thorax in planning repeated open heart surgery. Twenty-eight patients (mean age, 68 years) scheduled for repeated cardiac surgery who had undergone previous coronary artery bypass grafting (n=19) or cardiac valve replacement (8) or combined valvular and bypass surgery (1) underwent contrast-enhanced ECG-gated DSCT (Somatom Definition, Siemens Medical Solutions) of the whole thorax with a temporal resolution of 82 ms and a spatial resolution of 0.4 mm³. The indication for repeated surgery was bypass surgery (N.=6), valve replacement (16), combined bypass and valvular surgery (5) or other reasons (1). Assessment of surgical risk based on DSCT data were performed in terms of the relation of the ascending aorta and cardiac structures to the expected median sternotomy line, graft patency and anatomic course, and the degree of calcification of the ascending aorta and coronary arteries. DSCT findings led to a change of surgical approach for 9/28 (32.1%) patients (non-midline incision, N.=3; surgery performed under circulatory arrest, N.=5; peripheral arterial cannulation before sternotomy, N.=1) and cancellation of surgery for 4/28 (14.3%) patients (heavy aortic and coronary calcifications impeding bypass surgery, N.=2; right heart or aortic aneurysm in close proximity to the sternum in high risk patients, N.=2). The planned surgical approach remained unchanged after DSCT for the remaining15/28 (53.6%) patients. Of 54 bypass graft conduits (20 arterial, 34 venous) visualized on DSCT in 20 patients after previous bypass grafting, 16 arterial and 24 venous grafts were patent, while 4 arterial and 10 venous grafts were occluded. DSCT of the heart and thorax is an effective, non-invasive tool for the preoperative planning of repeated cardiac surgery. The technique provides significant information to modify the surgical approach and may increase the safety of the procedure.
- 10 January 2012
- Published by Elsevier in Forensic Science International
- Vol. 214 (1-3) , 118-123
Postmortem 24-h interval computed tomography findings on intrahepatic gas development and changes of liver parenchyma radiopacity
- 10 January 2012
- Published by Elsevier in Forensic Science International
- Vol. 214 (1-3) , 118-123
Postmortem 24-h interval computed tomography findings on intrahepatic gas development and changes of liver parenchyma radiopacity