George Papachristou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
George Papachristou has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
John Sourlas
2nd Department of Orthopaedics University of Athens Constantopoulion Hospital N. Ionia Greece
6 shared publicationsSpyros Plessas
2nd Department of Orthopaedics University of Athens Constantopoulion Hospital N. Ionia Greece
5 shared publicationsKonstantinos Papachristou
2nd Department of Orthopaedics University of Athens Constantopoulion Hospital N. Ionia Greece
3 shared publicationsC. Levidiotis
2nd University Department of Orthopaedics, National and Kapodistrian University, Constantopoulion Hospital, Athens, Greece
2 shared publicationsConstantine Levidiotis
2 shared publicationsE. Chronopoulos
2nd University Department of Orthopaedics, National and Kapodistrian University, Constantopoulion Hospital, Athens, Greece
2 shared publications
Latest Publications
- 13 October 2007
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 16 (4) , 420-426
Arthroscopic ACL reconstruction with Δ plasty: an innovative approach with hamstrings’ transfer and double tibial tunnel
We propose a new technique, with double bundle, double tibial tunnels with a bridge between them, using the hamstrings as auto‐grafts, retaining either their central or peripheral attachment. A prospective series of 41 patients underwent primary reconstruction of the anterior cruciate ligament by one surgeon, arthroscopically and electronically assisted; 37 were men and 4 were women with a mean age of 24.7 years. The mean follow‐up was19.05 (12–30) months. Normal function and joint stability was achieved. The patients returned to full occupational activities within 3–6 months after the operation. The function of hamstrings was not disturbed. Two patients have sustained a new injury without rupture of the grafts. The Noulis‐Lachman test was negative in 35 knees. Positive Pivot shift, post‐operatively, was present in 15.45% of patients. The IKDC score was 84.55. In the proposed ACL reconstruction technique, the two tendons are transferred and used as grafts, with gracillis and semitendinosus retaining their distal and central attachment, respectively; the former superimposed upon the latter while entering the femoral tunnel. The tibial tunnels leave a bone bridge ranging between 12 and 15 mm within the footprints of ACL. The two bundles are tensioned, each at different angle. This configuration imitates both the anatomy and the function of ACL and controls not only the anterior translation, but also the rotatory stability. With this innovative technique, the final outcome is improved, thus being closer to normal, as evidenced from previous experiments and the present prospective series.
- 13 October 2007
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 16 (4) , 420-426
Arthroscopic ACL reconstruction with Δ plasty: an innovative approach with hamstrings’ transfer and double tibial tunnel
We propose a new technique, with double bundle, double tibial tunnels with a bridge between them, using the hamstrings as auto‐grafts, retaining either their central or peripheral attachment. A prospective series of 41 patients underwent primary reconstruction of the anterior cruciate ligament by one surgeon, arthroscopically and electronically assisted; 37 were men and 4 were women with a mean age of 24.7 years. The mean follow‐up was19.05 (12–30) months. Normal function and joint stability was achieved. The patients returned to full occupational activities within 3–6 months after the operation. The function of hamstrings was not disturbed. Two patients have sustained a new injury without rupture of the grafts. The Noulis‐Lachman test was negative in 35 knees. Positive Pivot shift, post‐operatively, was present in 15.45% of patients. The IKDC score was 84.55. In the proposed ACL reconstruction technique, the two tendons are transferred and used as grafts, with gracillis and semitendinosus retaining their distal and central attachment, respectively; the former superimposed upon the latter while entering the femoral tunnel. The tibial tunnels leave a bone bridge ranging between 12 and 15 mm within the footprints of ACL. The two bundles are tensioned, each at different angle. This configuration imitates both the anatomy and the function of ACL and controls not only the anterior translation, but also the rotatory stability. With this innovative technique, the final outcome is improved, thus being closer to normal, as evidenced from previous experiments and the present prospective series.
- 11 July 2007
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 15 (10) , 1175-1180
ACL reconstruction with semitendinosus tendon autograft without detachment of its tibial insertion: a histologic study in a rabbit model
The purpose of this study was to evaluate the histologic changes that occur between 3 and 12 weeks in an intra‐articular, semitendinosus autograft, which was harvested without detachment of its tibial insertion and was placed through tibial and femoral drill holes, in a rabbit model. About 30 New Zealand white rabbits underwent ACL replacement using a semitendinosus tendon autograft. The normal ACL was transected at its femoral and tibial insertions. The tendon graft was harvested without detachment of its tibial insertion and its free end was secured with sutures. The graft was then passed through one tibial and one femoral tunnel and secured at the lateral femoral condyle. All animals were divided into three groups and were killed at 3, 6 and 12 weeks after surgery. Nine more animals underwent ACL reconstruction using a free semitendinosus tendon autograft. These animals were used as controls. The intra‐articular portion of the graft and the interface between the bone tunnel and the graft was evaluated postoperatively for gross morphology and histological appearance. Results of this study showed that in a rabbit model the semitendinosus tendon autograft retained its viability when harvested without detachment of its peripheral insertion. On contrary, at the control group, necrosis of the graft was observed 3 weeks after surgery and progressively revascularization and maturation occurred 6 and 12 weeks after surgery. Retaining the tibial insertion of the semitendinosus autograft seems to preserves its viability and bypasses the stages of avascular necrosis and revascularization that occurs with the use of a free tendon autograft.
- 11 July 2007
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 15 (10) , 1175-1180
ACL reconstruction with semitendinosus tendon autograft without detachment of its tibial insertion: a histologic study in a rabbit model
The purpose of this study was to evaluate the histologic changes that occur between 3 and 12 weeks in an intra‐articular, semitendinosus autograft, which was harvested without detachment of its tibial insertion and was placed through tibial and femoral drill holes, in a rabbit model. About 30 New Zealand white rabbits underwent ACL replacement using a semitendinosus tendon autograft. The normal ACL was transected at its femoral and tibial insertions. The tendon graft was harvested without detachment of its tibial insertion and its free end was secured with sutures. The graft was then passed through one tibial and one femoral tunnel and secured at the lateral femoral condyle. All animals were divided into three groups and were killed at 3, 6 and 12 weeks after surgery. Nine more animals underwent ACL reconstruction using a free semitendinosus tendon autograft. These animals were used as controls. The intra‐articular portion of the graft and the interface between the bone tunnel and the graft was evaluated postoperatively for gross morphology and histological appearance. Results of this study showed that in a rabbit model the semitendinosus tendon autograft retained its viability when harvested without detachment of its peripheral insertion. On contrary, at the control group, necrosis of the graft was observed 3 weeks after surgery and progressively revascularization and maturation occurred 6 and 12 weeks after surgery. Retaining the tibial insertion of the semitendinosus autograft seems to preserves its viability and bypasses the stages of avascular necrosis and revascularization that occurs with the use of a free tendon autograft.
- Open Access
- 6 March 2007
- Published by Springer Nature in International Orthopaedics
- Vol. 32 (4) , 483-488
Comparison of fixation methods of double-bundle double-tibial tunnel ACL reconstruction and double-bundle single-tunnel technique
An experimental study was conducted in order to evaluate biomechanical methods of single-bundle reconstruction in ACL and compare it with a new double-bundle double-tibial tunnel technique. Twenty-four porcine cadaver knees, divided into 4 groups of 6 knees each and 48 proper extensors of the fourth toe tendons, were used for the fixation techniques. In groups A and B, a double-bundle technique with a single femoral and tibial tunnel was used, fixed to a femoral and tibial post with screws and with buttons, respectively. In groups C and D, a double-bundle technique (technique Δ) with two separate tibial tunnels was used, fixed to a femoral and tibial post with screws and with buttons, respectively. A material testing system (Instron) was used for anteriorly translating the tibia until failure. The femoral and tibial post as a fixation method is superior to the conventional buttons technique. The more anatomical double-bundle reconstruction technique provided significantly higher structural properties and smaller loss of fixation compared with the single-bundle reconstruction technique. The comparison of the two techniques gave superior results to the femoral and tibial screws over the buttons. The double-bundle technique attempts to restore the anterior stability of the knee joint.
- 6 March 2007
- Published by Springer Nature in International Orthopaedics
- Vol. 32 (4) , 483-488
Open AccessComparison of fixation methods of double-bundle double-tibial tunnel ACL reconstruction and double-bundle single-tunnel technique
An experimental study was conducted in order to evaluate biomechanical methods of single-bundle reconstruction in ACL and compare it with a new double-bundle double-tibial tunnel technique. Twenty-four porcine cadaver knees, divided into 4 groups of 6 knees each and 48 proper extensors of the fourth toe tendons, were used for the fixation techniques. In groups A and B, a double-bundle technique with a single femoral and tibial tunnel was used, fixed to a femoral and tibial post with screws and with buttons, respectively. In groups C and D, a double-bundle technique (technique Δ) with two separate tibial tunnels was used, fixed to a femoral and tibial post with screws and with buttons, respectively. A material testing system (Instron) was used for anteriorly translating the tibia until failure. The femoral and tibial post as a fixation method is superior to the conventional buttons technique. The more anatomical double-bundle reconstruction technique provided significantly higher structural properties and smaller loss of fixation compared with the single-bundle reconstruction technique. The comparison of the two techniques gave superior results to the femoral and tibial screws over the buttons. The double-bundle technique attempts to restore the anterior stability of the knee joint.
- 30 August 2006
- Published by Springer Nature in International Orthopaedics
- Vol. 31 (4) , 465-470
ACL reconstruction and the implication of its tibial attachment for stability of the joint: anthropometric and biomechanical study
The planar topography of the anterior cruciate ligament (ACL) insertion was investigated and correlated to the use of the double-bundle/double tibial tunnel ACL reconstruction technique within the ACL tibial insertion area. The anteroposterior and mediolateral length of the tibial ACL attachment and the distances of the tibial insertion area from the anterior and posterior tibial borders were measured and the stability of the joint was tested using the double-bundle/double tibial tunnel ACL reconstruction technique. The anteroposterior length, 19.54 mm in men and 17.36 mm in women, of the ACL insertion, averaged approximately 40% of the total intercondylar anteroposterior dimension of the plateau. This broad distribution of insertion fibres ensures ligament tension and hence joint stability. The reported anteroposterior broad insertion of ACL fibres to the tibia is not sufficiently reproduced by the use of one or more bundles having a common tibial tunnel for the ACL reconstruction. In our view, this might be better achieved with two different bundles, with separate tunnels, and independent tensioning in different knee angles. This technique might achieve better results in human knee stability as opposed to other reported techniques. Une étude topographique de l’insertion du ligament croisé antérieur a recherchée une corrélation avec la technique du double tunnel/ double brin au niveau de la zone d’insertion tibiale. Les dimensions antéro-postérieure et médio-latérale de l’insertion tibiale ainsi que les distances entre les bords antérieur et postérieur du tibia et cette zone d’insertion étaient étudiées. La stabilité articulaire était testée après reconstruction par la technique du double brin avec double tunnel. La longueur antéro-postérieure de l’insertion - 19,54 mm chez l’homme et 17,36 chez la femme - représente approximativement 40% de la dimension antéro-postérieure du plateau tibial dans la région inter-condylienne. Cette distribution étendue de l’insertion des fibres assure la tension ligamentaire et en conséquence la stabilité articulaire. Cette insertion étendue n’est pas reproduite par l’utilisation d’un ou plusieurs brins passés dans un seul tunnel tibial. Nous pensons que cela peut être atteint en utilisant 2 brins et 2 tunnels avec une mise en tension indépendante dans les différentes positions du genou. Cette technique devrait donner de meilleurs résultats que les techniques habituellement proposées.
- 30 August 2006
- Published by Springer Nature in International Orthopaedics
- Vol. 31 (4) , 465-470
ACL reconstruction and the implication of its tibial attachment for stability of the joint: anthropometric and biomechanical study
The planar topography of the anterior cruciate ligament (ACL) insertion was investigated and correlated to the use of the double-bundle/double tibial tunnel ACL reconstruction technique within the ACL tibial insertion area. The anteroposterior and mediolateral length of the tibial ACL attachment and the distances of the tibial insertion area from the anterior and posterior tibial borders were measured and the stability of the joint was tested using the double-bundle/double tibial tunnel ACL reconstruction technique. The anteroposterior length, 19.54 mm in men and 17.36 mm in women, of the ACL insertion, averaged approximately 40% of the total intercondylar anteroposterior dimension of the plateau. This broad distribution of insertion fibres ensures ligament tension and hence joint stability. The reported anteroposterior broad insertion of ACL fibres to the tibia is not sufficiently reproduced by the use of one or more bundles having a common tibial tunnel for the ACL reconstruction. In our view, this might be better achieved with two different bundles, with separate tunnels, and independent tensioning in different knee angles. This technique might achieve better results in human knee stability as opposed to other reported techniques. Une étude topographique de l’insertion du ligament croisé antérieur a recherchée une corrélation avec la technique du double tunnel/ double brin au niveau de la zone d’insertion tibiale. Les dimensions antéro-postérieure et médio-latérale de l’insertion tibiale ainsi que les distances entre les bords antérieur et postérieur du tibia et cette zone d’insertion étaient étudiées. La stabilité articulaire était testée après reconstruction par la technique du double brin avec double tunnel. La longueur antéro-postérieure de l’insertion - 19,54 mm chez l’homme et 17,36 chez la femme - représente approximativement 40% de la dimension antéro-postérieure du plateau tibial dans la région inter-condylienne. Cette distribution étendue de l’insertion des fibres assure la tension ligamentaire et en conséquence la stabilité articulaire. Cette insertion étendue n’est pas reproduite par l’utilisation d’un ou plusieurs brins passés dans un seul tunnel tibial. Nous pensons que cela peut être atteint en utilisant 2 brins et 2 tunnels avec une mise en tension indépendante dans les différentes positions du genou. Cette technique devrait donner de meilleurs résultats que les techniques habituellement proposées.
- 29 May 2006
- Vol. 12 (6) , CR264-8
Cementless LCS rotating-platform knee arthroplasty in patients over 60 years without patella replacement: a mid-term clinical-outcome study.
The aim of this prospective paper is to present the results of a cementless LCS rotating-platform artificial knee design without resurfacing of the patella in patients over 60 years of age. In this prospective series, 234 patients were included with 251 knees. The LCS rotating-platform uncemented design was used in all cases, without replacement of the patella. Thirty-four patients were men and 200 were women. Two hundred three patients were suffering from osteoarthrosis (10 bilateral) and 31 patients (7 bilateral) from rheumatoid arthritis. Seventeen patients had a bilateral procedure. Prophylactic antibiotics and anticoagulants were also instituted to all patients. Forty-nine patients developed deep vein thrombosis and responded well to the applied conservative treatment. Overall results in the first 251 cementless cases at 2 to 9.8 years' follow-up (average: 5.7 years) were good to excellent in 94.4%, fair in 4.7%, and poor in 0.7%. Radiographs of the knees showed good bonding and no signs of radiolucency. The average clinical and functional Knee Society Ratings were 21.07 points and 30.95 points, respectively, preoperatively and 87.95 points and 78.56 points, respectively, at the final follow-up evaluation. With an average follow-up of 5.7 years, uncemented LCS rotating-platform knee joint arthroplasty without replacing the patella in patients over 60 years old was found to perform well, with encouraging clinical and radiological results and a survival rate of 98.1%.
- 29 May 2006
- Vol. 12 (6) , CR264-8
Cementless LCS rotating-platform knee arthroplasty in patients over 60 years without patella replacement: a mid-term clinical-outcome study.
The aim of this prospective paper is to present the results of a cementless LCS rotating-platform artificial knee design without resurfacing of the patella in patients over 60 years of age. In this prospective series, 234 patients were included with 251 knees. The LCS rotating-platform uncemented design was used in all cases, without replacement of the patella. Thirty-four patients were men and 200 were women. Two hundred three patients were suffering from osteoarthrosis (10 bilateral) and 31 patients (7 bilateral) from rheumatoid arthritis. Seventeen patients had a bilateral procedure. Prophylactic antibiotics and anticoagulants were also instituted to all patients. Forty-nine patients developed deep vein thrombosis and responded well to the applied conservative treatment. Overall results in the first 251 cementless cases at 2 to 9.8 years' follow-up (average: 5.7 years) were good to excellent in 94.4%, fair in 4.7%, and poor in 0.7%. Radiographs of the knees showed good bonding and no signs of radiolucency. The average clinical and functional Knee Society Ratings were 21.07 points and 30.95 points, respectively, preoperatively and 87.95 points and 78.56 points, respectively, at the final follow-up evaluation. With an average follow-up of 5.7 years, uncemented LCS rotating-platform knee joint arthroplasty without replacing the patella in patients over 60 years old was found to perform well, with encouraging clinical and radiological results and a survival rate of 98.1%.
- 11 May 2006
- Published by Springer Nature in International Orthopaedics
- Vol. 30 (5) , 403-408
Deterioration of long-term results following high tibial osteotomy in patients under 60 years of age
We have investigated, in a prospective study, the outcome of a valgus osteotomy of the tibia in patients less than 60 years of age with arthrosis of the medial compartment and a varus angle of no more than 177.7°. Included in the study were 44 high tibial osteotomies (HTO) performed in 42 patients from 1981 until 1996. There were 35 females (2 bilateral) and 7 males, with an average age of 51 years (range: 30–60 years). Only patients in the first three grades, according to Ahlback’s classification, were included. During a mean follow-up period of 10 years (range: 5–17 years), all but 2 patients experienced pain relief. The average loss of postoperative correction at 10 years was 2.4°. The average postoperative Hospital for Special Surgery Knee Rating System score (HSSK) for patients with excellent or good results was 83.5 points. Survivorship analysis showed a success rate of 80% and 66% at 10 and 15 years respectively, and over 52.8% at 17 years of follow-up. HTO results in redistribution of the main stresses towards normal levels, although normal values are never attained. This is probably the reason why patients experienced good results only in the medium term.
- 11 May 2006
- Published by Springer Nature in International Orthopaedics
- Vol. 30 (5) , 403-408
Deterioration of long-term results following high tibial osteotomy in patients under 60 years of age
We have investigated, in a prospective study, the outcome of a valgus osteotomy of the tibia in patients less than 60 years of age with arthrosis of the medial compartment and a varus angle of no more than 177.7°. Included in the study were 44 high tibial osteotomies (HTO) performed in 42 patients from 1981 until 1996. There were 35 females (2 bilateral) and 7 males, with an average age of 51 years (range: 30–60 years). Only patients in the first three grades, according to Ahlback’s classification, were included. During a mean follow-up period of 10 years (range: 5–17 years), all but 2 patients experienced pain relief. The average loss of postoperative correction at 10 years was 2.4°. The average postoperative Hospital for Special Surgery Knee Rating System score (HSSK) for patients with excellent or good results was 83.5 points. Survivorship analysis showed a success rate of 80% and 66% at 10 and 15 years respectively, and over 52.8% at 17 years of follow-up. HTO results in redistribution of the main stresses towards normal levels, although normal values are never attained. This is probably the reason why patients experienced good results only in the medium term.
- 14 December 2005
- Published by Springer Nature in International Orthopaedics
- Vol. 30 (1) , 21-25
Total hip arthroplasty for developmental hip dysplasia
We reviewed 38 hip replacements in 33 female patients (mean age 55.3 years) with developmental hip dysplasia. One patient had died and the remaining 32 patients (36 hips) had a mean follow-up of 12.2 years (range 8–19 years). All hips were replaced using the Müller cemented implant, and in 32 hips bulk femoral head autograft was used. In 33 hips the socket was reconstructed at the level of the true acetabulum. Complications included one intra-operative femoral fracture and two early dislocations. Correction of leg length discrepancy was possible in 30 patients. The post-operative mean modified Merle d’Aubigne and Postel scores for pain, movement and walking were 5.9, 5, and 5.3 respectively. One cup was revised due to aseptic loosening at ten years. All grafts united, but minor graft resorption was noticed in 24 hips, moderate in 2 hips and major in 1 hip.
- 14 December 2005
- Published by Springer Nature in International Orthopaedics
- Vol. 30 (1) , 21-25
Total hip arthroplasty for developmental hip dysplasia
We reviewed 38 hip replacements in 33 female patients (mean age 55.3 years) with developmental hip dysplasia. One patient had died and the remaining 32 patients (36 hips) had a mean follow-up of 12.2 years (range 8–19 years). All hips were replaced using the Müller cemented implant, and in 32 hips bulk femoral head autograft was used. In 33 hips the socket was reconstructed at the level of the true acetabulum. Complications included one intra-operative femoral fracture and two early dislocations. Correction of leg length discrepancy was possible in 30 patients. The post-operative mean modified Merle d’Aubigne and Postel scores for pain, movement and walking were 5.9, 5, and 5.3 respectively. One cup was revised due to aseptic loosening at ten years. All grafts united, but minor graft resorption was noticed in 24 hips, moderate in 2 hips and major in 1 hip.
- 1 December 2004
- Published by Elsevier in Revue de Chirurgie Orthopedique Et Reparatrice de L'appareil Moteur
- Vol. 90 (8) , 714-721
Ostéotomie d’horizontalisation de la glène radiale dans les pseudarthroses du scaphoïde carpien
- 1 December 2004
- Published by Elsevier in Revue de Chirurgie Orthopedique Et Reparatrice de L'appareil Moteur
- Vol. 90 (8) , 714-721
Ostéotomie d’horizontalisation de la glène radiale dans les pseudarthroses du scaphoïde carpien
- 1 June 2004
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 124 (5) , 288-297
Photoelastic study of the internal and contact stresses on the knee joint before and after osteotomy
Introduction The treatment of knee osteoarthrosis represents a difficult task. Osteotomy is one of the treatment regimes which, in earlier times, was the only surgical procedure giving reliable mid-term results. The improvement was attributed either to the changing of the acting forces or to the so-called biological factor. The use of a photoelastic model allows the observation of the direction of the significant contact and internal stresses at every point in a single plane. Materials and methods In the present study, we investigated the stress-strain situation of the knee joints in models made from 1 cm thick Araldite plates. These models reproduce tracings from anteroposterior X-ray views of monopodal loading of human knee joints. The models represent: normal knee joints, normal varus or valgus knee joint, knee joints suffering osteoarthrosis in varus or valgus, and knee joints suffering osteoarthrosis, following corrective osteotomies. The models were first loaded along the longitudinal axis with the leg in full extension, with 70 kg (body weight) and then with 140 kg, representing double the normal body weight. Results The application of longitudinal force on a normal knee joint, in full extension, results in symmetrical arrangement of trajectories in the condyles. Loading of the leg in varus or valgus produces shifting of stresses towards the inclination side. Increased contact stresses are always greater in the tibial condyles. The concentration of strain is directed towards the cortices of the loaded area. In a knee joint with osteoarthrosis, deviation of the trajectories in the condyles towards the inclination of the leg axis is observed. Also, increased contact stresses appear in the articular surfaces, on the inclination side. Isoclinics have meeting points on the loaded cortices. Supracondylar femoral osteotomy, or high tibial osteotomy, restores the axis of the leg, redistributes internal stresses (strain) in the condyles, corrects the trajectorial lines, and redistributes contact stresses in the articular surfaces towards the normal values. Conclusion Correction of the femorotibial axis results in redistribution of the isochromatics, isoclinics, trajectorial lines and contact stresses. The values of the above parameters are corrected and remain closer to these of the normal knee, but in no case does the correction of all the above factors attain normal values. The change of direction of the main stresses following osteotomies towards those of the normal knee probably represents the biomechanical explanation of the way the osteotomy relieves pain and improves function.
- 1 June 2004
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 124 (5) , 288-297
Photoelastic study of the internal and contact stresses on the knee joint before and after osteotomy
Introduction The treatment of knee osteoarthrosis represents a difficult task. Osteotomy is one of the treatment regimes which, in earlier times, was the only surgical procedure giving reliable mid-term results. The improvement was attributed either to the changing of the acting forces or to the so-called biological factor. The use of a photoelastic model allows the observation of the direction of the significant contact and internal stresses at every point in a single plane. Materials and methods In the present study, we investigated the stress-strain situation of the knee joints in models made from 1 cm thick Araldite plates. These models reproduce tracings from anteroposterior X-ray views of monopodal loading of human knee joints. The models represent: normal knee joints, normal varus or valgus knee joint, knee joints suffering osteoarthrosis in varus or valgus, and knee joints suffering osteoarthrosis, following corrective osteotomies. The models were first loaded along the longitudinal axis with the leg in full extension, with 70 kg (body weight) and then with 140 kg, representing double the normal body weight. Results The application of longitudinal force on a normal knee joint, in full extension, results in symmetrical arrangement of trajectories in the condyles. Loading of the leg in varus or valgus produces shifting of stresses towards the inclination side. Increased contact stresses are always greater in the tibial condyles. The concentration of strain is directed towards the cortices of the loaded area. In a knee joint with osteoarthrosis, deviation of the trajectories in the condyles towards the inclination of the leg axis is observed. Also, increased contact stresses appear in the articular surfaces, on the inclination side. Isoclinics have meeting points on the loaded cortices. Supracondylar femoral osteotomy, or high tibial osteotomy, restores the axis of the leg, redistributes internal stresses (strain) in the condyles, corrects the trajectorial lines, and redistributes contact stresses in the articular surfaces towards the normal values. Conclusion Correction of the femorotibial axis results in redistribution of the isochromatics, isoclinics, trajectorial lines and contact stresses. The values of the above parameters are corrected and remain closer to these of the normal knee, but in no case does the correction of all the above factors attain normal values. The change of direction of the main stresses following osteotomies towards those of the normal knee probably represents the biomechanical explanation of the way the osteotomy relieves pain and improves function.
- 1 August 2003
- Vol. 69 (4) , 341-5
Isolated meniscal repair in the avascular area.
The authors present the results of a prospective cohort study carried out in young patients, to evaluate the outcome of meniscal repair in the avascular region of the meniscus. Forty five patients underwent either open (23 patients) or arthroscopic repair (22 patients) between 1982 and 1992. Seventeen men and eight women were included in the present study; their ages at the time of admission ranged from 16 to 27 years. They all presented with isolated longitudinal tears in the central avascular region of the meniscus. No patient with any kind of concomitant lesion was included in this series. The stitches were usually passed through the injured area and the synovium, and the knots were tightened outside the capsule. Twenty five patients of the total series, were subjected to a clinical examination in 1993, 9 to 54 months after meniscal suture. The Lysholm Knee Rating Score and the Tegner Activity Test were used. During 1999, these patients responded to a written questionnaire, based on the above mentioned rating scales. Among the 25 patients, there were 4 recurrences (16%), 2 fair results (8%) and one partial healing (4%). Eighteen (72%) patients, among which eight were treated using the arthroscopic technique, have shown favourable results, without any symptoms from the tibiofemoral joint, based on clinical examination and on the Lysholm Rating Scale and the Tegner Activity Test. When confronted with meniscal tears where there is doubt regarding the vascularity of the injured area, surgical repair in the avascular zone appears to provide a reasonable probability of healing, with good clinical outcome.
- 1 August 2003
- Vol. 69 (4) , 341-5
Isolated meniscal repair in the avascular area.
The authors present the results of a prospective cohort study carried out in young patients, to evaluate the outcome of meniscal repair in the avascular region of the meniscus. Forty five patients underwent either open (23 patients) or arthroscopic repair (22 patients) between 1982 and 1992. Seventeen men and eight women were included in the present study; their ages at the time of admission ranged from 16 to 27 years. They all presented with isolated longitudinal tears in the central avascular region of the meniscus. No patient with any kind of concomitant lesion was included in this series. The stitches were usually passed through the injured area and the synovium, and the knots were tightened outside the capsule. Twenty five patients of the total series, were subjected to a clinical examination in 1993, 9 to 54 months after meniscal suture. The Lysholm Knee Rating Score and the Tegner Activity Test were used. During 1999, these patients responded to a written questionnaire, based on the above mentioned rating scales. Among the 25 patients, there were 4 recurrences (16%), 2 fair results (8%) and one partial healing (4%). Eighteen (72%) patients, among which eight were treated using the arthroscopic technique, have shown favourable results, without any symptoms from the tibiofemoral joint, based on clinical examination and on the Lysholm Rating Scale and the Tegner Activity Test. When confronted with meniscal tears where there is doubt regarding the vascularity of the injured area, surgical repair in the avascular zone appears to provide a reasonable probability of healing, with good clinical outcome.