SCSean O. Casey

Sean O. Casey

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sean O. Casey has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • CT perfusion imaging in the management of posterior reversible encephalopathy

    by S. O. Casey, A. McKinney, M. Teksam, H. Liu, C. L. Truwit

    A 13-year-old girl with a renal transplant presented with hypertension and seizures. CT and MRI demonstrated typical bilateral parietal, occipital and posterior frontal cortical and subcortical edema, thought to represent posterior reversible encephalopathy syndrome. The cause was presumed to be hypertension. Antihypertensive therapy was started, lowering of the blood pressure in the range of 110–120 mmHg systolic. However, stable xenon (Xe) CT perfusion imaging revealed ischemia within the left parietal occipital region. The antihypertensive was adjusted which increased both the systolic and diastolic blood pressure by 31 mm Hg. The patient was re-imaged with Xe CT and was found to have resolution of the ischemic changes within the left parietal occipital region. In this report, we present a case in which stable Xe CT was used to monitor the degree of cerebral perfusion and guide titration of antihypertensive therapy. Such brain perfusion monitoring may have helped to prevent infarction of our patient.


  • Intraspinal epidermoid cyst: diffusion-weighted MRI

    by M. Teksam, S. O. Casey, E. Michel, M. Benson, C. L. Truwit

    We report a 7-year-old boy who presented with two-month history of worsening low back and right leg pain. Conventional MR images demonstrated a poorly outlined intradural mass recognized by the displacement of the conus medullaris and the nerve roots of the cauda equina at the L2–3 level. The signal intensity of the lesion was similar to CSF. There was no contrast enhancement of the lesion. Diffusion-weighted images and ADC values revealed restricted diffusion within the mass. Myelography confirmed the mass as an intradural filling defect with myelographic block at the L2–3 level. The patient underwent total surgical excision of the mass. Pathologic examination revealed the diagnosis of epidermoid cyst.


    • 1 August 2000
      • Vol. 21  (7) , 1199-1206

    Posterior Reversible Encephalopathy Syndrome: Utility of Fluid-attenuated Inversion Recovery MR Imaging in the Detection of Cortical and Subcortical Lesions

    by Sean O. Casey, Ricardo C. Sampaio, Eduard Michel, Charles L. Truwit

    BACKGROUND AND PURPOSE: Posterior reversible encephalopathy syndrome (PRES) is typically characterized by headache, altered mental functioning, seizures, and visual loss associated with imaging findings of bilateral subcortical and cortical edema with a predominantly posterior distribution. Our goal was to determine whether fluid-attenuated inversion recovery (FLAIR) imaging improves the ability to detect subtle peripheral lesions of PRES, as compared with conventional MR techniques.


    • 1 February 2000
      • Vol. 21  (2) , 243-245

    Pontine Reversible Edema: A Newly Recognized Imaging Variant of Hypertensive Encephalopathy?

    by Sean O. Casey, Charles L. Truwit


    • 10 December 1999
      • Vol. 20  (10) , 1839-1841

    Pallister-Hall Syndrome: Clinical and MR Features

    by Jeffrey S. Kuo, Sean O. Casey, Linda Thompson, Charles L. Truwit

    Summary: A 4-month-old boy with polydactyly and bifid epiglottis was found to have a large sellar and suprasellar mass. When the diagnosis of Pallister-Hall syndrome was made, conservative management was elected. When the patient was 2 years old, the tumor had grown proportionally with the patient, and he was developing appropriately. Although rare, this entity is important to recognize not only for clinical diagnosis but also for appropriate management and genetic counseling.


    • 1 September 1998
      • Vol. 19  (8) , 1513-1521

    Integral and shell-MIP display algorithms in MR and CT three-dimensional models of the brain surface.

    by S O Casey, D Rubinstein, K O Lillehei, R A Alberico, R R Ozsvath, A G Cajade-Law, B E Weprin, E Michel, C L Truwit

    Our purpose was to demonstrate the use of integral and shell maximum intensity projection (shell-MIP) display algorithms in the 3-D CT and MR depiction of cerebral gyral and surface venous anatomy and disorders. These new algorithms are compared against MIP and shaded-surface-display (SSD) algorithms. Integral and shell-MIP displays were generated from a specified number of proximal surface voxel layers in a 3-D model. Algorithmic models were compared on nine contrast-enhanced spoiled gradient-recalled acquisition in a steady state (SPGR) MR venograms for brain surface anatomic identification and detail. Seven CT venograms were compared for conspicuity of filling defects. Twelve contrast-enhanced preoperative planning 3-D MR models were rated for neurosurgical utility. A shell-MIP score of 7.00 and an integral score of 6.78 represented the highest mean subjective MR gyral quality (1-10 scale) followed by an SSD score of 3.89 and an MIP score of 1.06. Mean confidence scores for MR central sulcus identification (1-10 scale) were shell-MIP, 7.67; integral, 7.00; SSD, 3.22; and MIP, 1.00. Mean superficial venous quality MR ratings (1-10 scale) were shell-MIP, 8.22; MIP, 7.39; integral, 7.00; and SSD, 3.72. The mean number of cortical veins draining into each side of the superior sagittal sinus on MR was as follows: MIP, 6.19; integral, 6.06; shell-MIP, 5.94; and SSD, 3.81. Mean confidence scores for filling defect identification on CT venograms (1-5 scale) revealed a shell-MIP score of 4.36 and an integral score of 4.29 to be superior to a MIP score of 3.00. In selected cases, 3-D presurgical planning, prior to tumor resection, was clinically useful. Integral and shell-MIP are useful 3-D display algorithms for simultaneous display of superficial cerebral veins and gyri on MR images and of thrombosis on CT venograms.