SNShu-Hang Ng

Shu-Hang Ng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shu-Hang Ng has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • PET/CT and 3-T whole-body MRI in the detection of malignancy in treated oropharyngeal and hypopharyngeal carcinoma

    by Shu-Hang Ng, Sheng-Chieh Chan, Tzu-Chen Yen, Chun-Ta Liao, Chin-Yu Lin, Joseph Tung-Chieh Chang, Sheung-Fat Ko, Hung-Ming Wang, Kai-Ping Chang, Kang-Hsing Fan

    We performed a prospective comparison of the diagnostic capability of integrated fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) (PET/CT), 3-T whole-body magnetic resonance imaging (WB-MRI) and their combination in detecting malignancy in treated oropharyngeal or hypopharyngeal squamous cell carcinoma (OHSCC). Seventy-nine OHSCC patients at a high risk of residual disease or suspected to have recurrence after the completion of chemoradiation were included in the study. All patients underwent PET/CT and WB-MRI within 10 days of each other. Histology and follow-up data were used as the reference standard. The McNemar test was used to compare sensitivity and specificity, while the area under the receiver-operating characteristic curve (AUC) was used for comparison of diagnostic capabilities. Twenty-nine patients (36.7%) had residual/recurrent tumours or second primary tumours. Overall, there was a trend towards increased sensitivity and diagnostic capability for PET/CT compared with WB-MRI (72.4 vs 55.2%, p = 0.13; 0.826 vs 0.753, p = 0.24, respectively). The diagnostic capability of combined interpretation of PET/CT and WB-MRI was similar to PET/CT alone (0.827 vs 0.826, p = 0.97) but was significantly higher than WB-MRI alone (0.827 vs 0.753, p = 0.04). PET/CT showed a trend towards higher diagnostic capability than 3-T WB-MRI in detecting residual/recurrent tumours or second primary tumours in OHSCC. The combined use of PET/CT and WB-MRI provided more added value to WB-MRI alone than to PET/CT alone. Additional PET/CT can be useful in patients with questionable MRI findings of malignancy.


  • Comprehensive imaging of residual/recurrent nasopharyngeal carcinoma using whole-body MRI at 3 T compared with FDG-PET-CT

    by Shu-Hang Ng, Sheng-Chieh Chan, Tzu-Chen Yen, Chun-Ta Liao, Joseph Tung-Chieh Chang, Sheung-Fat Ko, Hung-Ming Wang, Chin-Yu Lin, Kai-Ping Chang, Yu-Chun Lin

    To prospectively compare the diagnostic potential of 3-T whole-body magnetic resonance imaging (WB-MRI) and integrated fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) (FDG-PET-CT), and their combined interpretation for the detection of residual/recurrent nasopharyngeal carcinoma (NPC). We enrolled 179 NPC patients at high risk of residual disease or with suspected recurrence. WB-MRI and FDG-PET-CT were obtained with an interval of 0.99; 0.929 vs. 0.924, P = 0.83, respectively). Combined interpretation of WB-MRI with FDG-PET-CT increased the sensitivity to 94.5%. A slight improvement in the diagnostic capability was obtained using a combined interpretation of WB-MRI and FDG-PET-CT over WB-MRI alone (0.952 vs. 0.929, P = 0.22) and FDG-PET-CT alone (0.952 vs. 0.924, P = 0.11). Three-Tesla WB-MRI achieved a similar diagnostic capability to FDG-PET-CT for the detection of residual/recurrent NPC. Both techniques have different advantages, and their combined interpretation can yield a slightly higher diagnostic capability. In clinical practice, 3-T WB-MRI can offer an accurate and comprehensive assessment of residual/recurrent NPC.


  • Pretreatment evaluation of distant-site status in patients with nasopharyngeal carcinoma: accuracy of whole-body MRI at 3-Tesla and FDG-PET-CT

    by Shu-Hang Ng, Sheng-Chieh Chan, Tzu-Chen Yen, Joseph Tung-Chieh Chang, Chun-Ta Liao, Sheung-Fat Ko, Hung-Ming Wang, Yau-Yau Wai, Jiun-Jie Wang, Min-Chi Chen


  • Staging of untreated nasopharyngeal carcinoma with PET/CT: comparison with conventional imaging work-up

    by Shu-Hang Ng, Sheng-Chieh Chan, Tzu-Chen Yen, Joseph Tung-Chieh Chang, Chun-Ta Liao, Sheung-Fat Ko, Feng-Yuan Liu, Shu-Chyn Chin, Kang-Hsing Fan, Cheng-Lung Hsu


  • Staging of untreated nasopharyngeal carcinoma with PET/CT: comparison with conventional imaging work-up

    by Shu-Hang Ng, Sheng-Chieh Chan, Tzu-Chen Yen, Joseph Tung-Chieh Chang, Chun-Ta Liao, Sheung-Fat Ko, Feng-Yuan Liu, Shu-Chyn Chin, Kang-Hsing Fan, Cheng-Lung Hsu

    We prospectively compared PET/CT and conventional imaging for initial staging of nasopharyngeal carcinoma (NPC). A total of 111 patients with histologically proven NPC were investigated with PET/CT and conventional imaging (head-and-neck MRI, chest X-ray, abdominal ultrasound, and bone scan) before treatment. The respective findings were reviewed independently and then compared with each other. With regard to T staging, PET/CT showed a discrepancy with head-and-neck MRI in 36 (32.4%) of the study subjects. With regard to N staging, PET/CT showed a discrepancy with head-and-neck MRI in 15 (13.5%) patients. Among the discordant cases, MRI was superior in demonstrating tumor involvement in the parapharyngeal space, skull base, intracranial area, sphenoid sinus, and retropharyngeal nodes while PET/CT was superior in demonstrating neck nodal metastasis. PET/CT disclosed 13 of 16 patients with distant malignancy compared with four patients disclosed by conventional imaging work-up. The false-positive rate of PET/CT was 18.8%. PET/CT correctly modified M staging in eight patients (7.2%) and disclosed a second primary lung malignancy in one patient (0.9%). In NPC patients, MRI appears to be superior to PET/CT for the assessment of locoregional invasion and retropharyngeal nodal metastasis. PET/CT is more accurate than MRI for determining cervical nodal metastasis and should be the better reference for the neck status. PET/CT has an acceptable diagnostic yield and a low false-positive rate for the detection of distant malignancy and can replace conventional work-up to this aim. PET/CT and head-and-neck MRI are suggested for the initial staging of NPC patients.


    • 1 July 2005
      • Vol. 46  (7) , 1136-43

    18F-FDG PET and CT/MRI in oral cavity squamous cell carcinoma: a prospective study of 124 patients with histologic correlation.

    by Shu-Hang Ng, Tzu-Chen Yen, Chun-Ta Liao, Joseph Tung-Chieh Chang, Sheng-Chieh Chan, Sheung-Fat Ko, Hung-Ming Wang, Ho-Fai Wong

    Accurate evaluation of primary tumors and cervical lymph node status of squamous cell carcinoma (SCC) of the oral cavity is important to treatment planning and prognosis prediction. In this prospective study, we evaluated the use of 18F-FDG PET, CT/MRI, and their visual correlation for the identification of primary tumors and cervical nodal metastases of SCC of the oral cavity with histologic correlation. One hundred twenty-four patients with pathologically proven diagnoses of oral cavity SCC underwent 18F-FDG PET and CT/MRI within 2 wk before surgery. We interpreted 18F-FDG PET, CT/MRI, and visually correlated 18F-FDG PET and CT/MRI separately to assess the primary tumors and their regional lymph node status. We recorded lymph node metastases according to the neck level system of imaging-based nodal classification. Histopathologic analysis was used as the gold standard for assessment of the primary tumors and lymph node involvement. We analyzed differences in sensitivity and specificity among the imaging modalities using the McNemar test. The receiver-operating-characteristic (ROC) curve and calculation of the area under the curve were used to evaluate their discriminative power. The accuracy of 18F-FDG PET, CT/MRI, and their visual correlation for the identification of primary tumors was 98.4%, 87.1%, and 99.2%, respectively. The sensitivity of 18F-FDG PET for the identification of nodal metastases on a level-by-level basis was 22.1% higher than that of CT/MRI (74.7% vs. 52.6%, P < 0.001), whereas the specificity of 18F-FDG PET was 1.5% lower than that of CT/MRI (93.0% vs. 94.5%, P = 0.345). The sensitivity and specificity of the visual correlation of 18F-FDG PET and CT/MRI were 3.2% and 1.5% higher than those of 18F-FDG PET alone (77.9% vs. 74.7%, P = 0.25; 94.5% vs. 93.0%, P = 0.18, respectively). The area under the curve obtained from the ROC curve showed that 18F-FDG PET was significantly superior to CT/MRI for total nodal detection (0.896 vs. 0.801, P = 0.002), whereas the visual correlation of 18F-FDG PET and CT/MRI was modestly superior to 18F-FDG PET alone (0.913 vs. 0.896, P = 0.28). 18F-FDG PET is superior to CT/MRI in the detection of cervical status of oral cavity SCC. The sensitivity of 18F-FDG PET for the detection of cervical nodal metastasis on a level-by-level basis was significantly higher than that of CT/MRI, whereas their specificities appeared to be similar. Visual correlation of 18F-FDG PET and CT/MRI showed a trend of increased diagnostic accuracy over 18F-FDG PET alone but without a statistically significant difference, and its sensitivity was still not high enough to replace pathologic lymph node staging based on neck dissection.


  • Are dual-phase 18F-FDG PET scans necessary in nasopharyngeal carcinoma to assess the primary tumour and loco-regional nodes?

    by Tzu-Chen Yen, Yu-Chen Chang, Sheng-Chieh Chan, Joseph Tung-Chieh Chang, Ching-Han Hsu, Kun-Ju Lin, Wuu-Jyh Lin, Ying-Kai Fu, Shu-Hang Ng

    This prospective study aimed to investigate the efficacy of dual-phase positron emission tomography (PET) in evaluating the loco-regional status of nasopharyngeal carcinoma (NPC). Eighty-four patients with newly diagnosed NPC and a fasting serum glucose level of 18F]fluoro-2-deoxy-D-glucose (18F-FDG) PET studies (at 40 min and 3 h after injection of 370 MBq 18F-FDG) and head and neck magnetic resonance imaging (MRI) were performed within 1 week. Diagnostic criteria for NPC comprised the histopathological findings, the joint judgments of the research team and the post-treatment outcome. Each lesion’s maximum standardised uptake value (SUV) and retention index were obtained. SUV data were evaluated using a paired t test. Receiver operating characteristic curves and calculation of the area under the curve (AUC) determined the discriminative power. 18F-FDG PET was significantly superior to MRI in identifying lower neck NPC nodal metastasis (AUC: 1 vs 0. 972, P=0.046) and overall loco-regional metastases (AUC: 0.985 vs 0.958, P=0.036). However, 18F-FDG PET was similar to MRI in detecting primary tumour, as well as retropharyngeal, upper neck and supraclavicular nodal metastases. There was no significant difference between early phase (40 min) and delayed phase (3 h) 18F-FDG PET in the detection of primary tumours (accuracy: 100% vs 100%) or loco-regional nodal metastasis (AUC: 0.984 vs 0.985, P=0.834). 18F-FDG PET is superior to MRI in identifying lower neck nodal metastasis of NPC. Additional 3-h 18F-FDG PET contributes no further information in the detection of primary tumours or loco-regional metastatic nodes in untreated NPC patients.