HDHartmut Dickhaus

Hartmut Dickhaus

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hartmut Dickhaus has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electromagnetic tracking for femoral derotation osteotomy—an in vivo study

    by Andreas Geisbüsch, Christoph Auer, Hartmut Dickhaus, Cornelia Putz, Thomas Dreher

    Femoral derotation osteotomy delivers good to excellent results in the treatment of rotational gait abnormalities and especially in internal rotation gait. The outcome of the procedure has been evaluated in numerous short and long term studies. Although reasons for recurrence and over-/under-correction have been unveiled in earlier studies the mechanisms are still not fully understood. False intra-operative assessment of the derotation angle may contribute to imprecise outcomes. In a recent saw-bone study we evaluated an electromagnetic tracking system in comparison to conventional goniometer measurement and a CT reference measurement and found it to be extremely accurate, whereas the use of a conventional goniometer for derotation measurement showed a high inter- and intra-rater variability. The current study evaluates the electromagnetic tracking system for continuous intraoperative derotation control under real OR conditions. Adults (age: 18-40 years) with the diagnosis of internal rotation gait, independent of the underling pathology, undergoing a supracondylar deroation osteotomy were included. A rotational CT scan was conducted before and in close proximity after surgery and the difference served as reference for the electromagnetic tracking results. The results showed a mean deviation of 2.6° (1.2°-5.5°) in comparison to the reference measurement of the pre- and post-operative CT scans. The system proved to be stable under OR conditions with a good usability and a small technical footprint. Electromagnetic tracking delivers a precise, reliable and independent assessment of intraoperative derotation angles in femoral derotation osteotomies. This article is protected by copyright. All rights reserved


  • Electromagnetic bone segment tracking to control femoral derotation osteotomy-A saw bone study

    by Andreas Geisbüsch, Christoph Auer, Hartmut Dickhaus, Mirjam Niklasch, Thomas Dreher

    Correction of rotational gait abnormalities is common practice in pediatric orthopaedics such as in children with cerebral palsy. Femoral derotation osteotomy is established as a standard treatment, however different authors reported substantial variability in outcomes following surgery with patients showing over- or under-correction. Only 60% of the applied correction is observed postoperatively, which strongly suggests intraoperative measurement error or loss of correction during surgery. This study was conducted to verify the impact of error sources in the derotation procedure and assess the utility of a newly developed, instrumented measurement system based on electromagnetic tracking aiming to improve the accuracy of rotational correction. A supracondylar derotation osteotomy was performed in 21 artificial femur sawbones and the amount of derotation was quantified during the procedure by the tracking system and by 9 raters using a conventional goniometer. Accuracy of both measurement devices was determined by repeated computer tomography scans. Average derotation measured by the tracking system differed by 0.1° ± 1.6° from the defined reference measurement. In contrast, a high inter-rater variability was found in goniometric measurements (range: 10.8° ± 6.9°, mean interquartile distance: 6.6°). During fixation of the osteosynthesis, the tracking system reliably detected unintentional manipulation of the correction angle with a mean absolute change of 4.0°±3.2°. Our findings show that conventional control of femoral derotation is subject to relevant observer bias whereas instrumental tracking yields accuracy better than ±2°. The tracking system is a step towards more reliable and safe implementation of femoral correction, promising substantial improvements of patient safety in the future. This article is protected by copyright. All rights reserved


  • OP-Planung und OP-Unterstützung durch biomedizinische Technik

    by Dr. H. Dickhaus, R. Metzner

    Ein grundlegender qualitativer Wandel bei operativen Eingriffen wurde mit der Einführung der minimal-invasiven Chirurgie erreicht. Ebenso bedeutsam sind in diesem Kontext neuartige Werkzeuge in der Mikrosystemtechnik. Hier ist die Entwicklung hin zu einer weiteren Integration keineswegs abgeschlossen. Entscheidende therapeutische Fortschritte konnten auch durch die zeitnahe Bereitstellung individueller Patientendaten erzielt werden. Diese reichen von der Bildgebung über elektrophysiologische oder funktionelle Registrierungen bis hin zu synthetischen Daten aus Modellierungen und Simulationen anatomischer oder physiologischer Gegebenheiten. Neben zahlreichen technischen Neuerungen zur Unterstützung der OP sind ein wirkungsvolles Qualitätsmanagement und ein optimierter Workflow für den Operationserfolg wesentlich. Die Vision automatisch gesteuerter Roboteroperationen wurde zugunsten eines permanent überwachten Eingriffs mit der Unterstützung intelligenter Werkzeuge in der Hand des Chirurgen fallen gelassen. Aktuelle Ergebnisse zur Rekonstruktions- und Transplantationschirurgie mittels Tissue-Engineering und molekularbiologischer Methoden markieren erst den Anfang einer möglicherweise vielversprechenden neuen Entwicklungslinie. Fundamental changes were achieved with the introduction of minimally invasive surgery. In this context, innovations in microtechnology played a significant role in the deployment of new tools. Developments for further integration are still ongoing. Furthermore, decisive progress was made by the timely provision of individual patient data prior to surgery. These comprise imaging data, electrophysiological or functional recordings, and synthetic data gained by modeling and simulation of anatomical or physiological conditions. Aside from the technical aspects of supporting surgery, effective quality management and optimized workflow are essential for therapeutic success. The vision of autonomously operating robots has been dropped in favor of permanently conducted and supervised interventions with the support of intelligent tools for the surgeon. Recent advances in reconstruction and transplantation surgery by tissue engineering and molecular biology are only the beginning of new promising concepts.

  • Open Access

    Nuclear staining and relative distance for quantifying epidermal differentiation in biomarker expression profiling

    by Thora Pommerencke, Thorsten Steinberg, Hartmut Dickhaus, Pascal Tomakidi, Niels Grabe

    Background: The epidermal physiology results from a complex regulated homeostasis of keratinocyte proliferation, differentiation and death and is tightly regulated by a specific protein expression during cellular maturation. Cellular in silico models are considered a promising and inevitable tool for the understanding of this complex system. Hence, we need to incorporate the information of the differentiation dependent protein expression in cell based systems biological models of tissue homeostasis. Such methods require measuring tissue differentiation quantitatively while correlating it with biomarker expression intensities. Results: Differentiation of a keratinocyte is characterized by its continuously changing morphology concomitant with its movement from the basal layer to the surface, leading to a decreased average nuclei density throughout the tissue. Based thereon, we designed and evaluated three different mathematical measures (nuclei based, distance based, and joint approach) for quantifying differentiation in epidermal keratinocytes. We integrated them with an immunofluorescent staining and image analysis method for tissue sections, automatically quantifying epidermal differentiation and measuring the corresponding expression of biomarkers. When studying five well-known differentiation related biomarkers in an epidermal neck sample only the resulting biomarker profiles incorporating the relative distance information of cells to the tissue borders (distance based and joint approach) provided a high-resolution view on the whole process of keratinocyte differentiation. By contrast, the inverse nuclei density approach led to an increased resolution at early but heavily decreased resolution at late differentiation. This effect results from the heavy non-linear decay of DAPI intensity per area, probably caused by cytoplasmic growth and chromatin decondensation. In the joint approach this effect could be compensated again by incorporating distance information. Conclusion: We suppose that key mechanisms regulating tissue homeostasis probably depend more on distance information rather than on nuclei reorganization. Concluding, the distance approach appears well suited for comprehensively observing keratinocyte differentiation.


    • 1 January 2007
      • Vol. 129, 1299-303

    Identification and genotype related classification of children with long QT-syndrome using 24 h Holter recordings.

    by Matthias Bauch, Annamaria Siegler, Markus Khalil, Jörg Zehelein, Herbert E Ulmer, Hartmut Dickhaus

    The long QT syndrome (LQTS) belongs to the family of hereditary diseases and can cause life-threatening arrhythmias and leads to sudden cardiac death. Mutations on six genes are responsible for changes in the electrophysiological properties of myocardial cells that are involved in the repolarization phase. In the surface ecg this is expressed by a prolonged QT interval and genotypespecific shapes for the T-Wave. The aim of the study was to find parameters that quantify properties of the repolarization phase which can be used in addition to the established Schwartz score in the process of diagnosing LQTS. Furthermore, ecg features were evaluated for the separation of the LQT subtypes LQT1, LQT2 and LQT3. The combination of the features PtA50 and QTc yielded with 93% sensitivity and 100% specificity the best results in the field of patient identification. Despite the small dataset consisting of 14 patients that was available for the second aim, the achieved results for the morphology indices motivate further research in this field.

    • 1 January 2007
      • Vol. 129, 1339-43

    Quantification of myocardial perfusion for CAD diagnosis.

    by Hartmut Dickhaus, Markus Erbacher, Helmut Kücherer

    We introduce a computer based algorithm for objective quantification of myocardial perfusion to support the diagnosis of cad patients. This new method is based on conventional cine angiographic films. In order to achieve maximal quality of the digital subtraction angiography images, the sequence is synchronized with the ECG. Optionally, the digital images can be motion compensated by a two step matching method. The spatio-temporal spread of blood, or the so-called blush, through the microvasculature to the myocardium--indicated by dye injection--represents a characteristic pattern for the myocardial perfusion. This dynamic temporal pattern is characterized by typical features as the maximal value of blush intensity, of increase and of decrease velocity which correspond with the different phases of flooding in and washout. On the basis of 100 different temporal blush profiles, an algorithm is established which classifies the acquired blush patterns into 4 different grades.


  • Short-Term Heart Rate Variability Response to Head-Up Tilt in Young Syncope Patients and Controls with Respect to Age

    by Hartmut Dickhaus, Christoph Maier, Markus Khalil, Herbert Ulmer

    This study aims at characterizing the short-term time-courses of time- and frequency-domain heart rate variability (HRV) parameters during head-up tilt test (HUTT). Data from 44 young patients with a history of syncope and 34 age-matched controls was analysed in two age-groups related to puberty (14 years), and separately for gender, by extracting minute-by-minute progression of mean RR-interval, standard deviation of RR-intervals (SDNN) and their first difference (SDSD) as well as low-frequency (LF, 0.05-0.15 Hz) energy, high-frequency (HF, 0.15-0.4 Hz) energy and the LF/HF-ratio. Time-courses were individually normalized and averaged after synchronization to the events of tilt and tilt-back/syncope. We observed remarkable age-related differences not only with respect to response to tilting but also regarding the differentiation of patients with positive HUTT from controls with negative HUTT. ROC-analysis in three regions of interest (0-2 min after tilt, 2-5 min after tilt, 5-2 min before tilt-back) revealed generally much weaker and less persistent differences in younger subjects whereas in elders the differences were clearer and often most pronounced immediately before syncope. For both age-groups, the relative change of mean RR provided best separation, however in elders in the ROI just before syncope (sensitivity: 74%, specificity 80%) in young immediately after tilt (sens.: 71%, spec.: 74%). In elder subjects, the relative reduction of SDNN 2-5 minute after tilt achieved almost the same performance (sens.: 74%, spec. 80%) as in the ROI before syncope (sens. 78%, spec. 73%), indicating the existence of rather early precursors of syncope that might help to predict the outcome of the HUTT in subjects in or after puberty


    • 1 January 2006
      • Vol. 124, 989-94

    Pre- and intraoperative processing and integration of various anatomical and functional data in neurosurgery.

    by Roland Metzner, Urs Eisenmann, Christian R Wirtz, Hartmut Dickhaus

    A software system is presented, capable of integrating various information sources for neurosurgical procedures. These include anatomical data such as a standard 3D DICOM image stacks, atlas data, as well as functional information (e.g. fmri, MEG, EEG). The system is programmed in C++ using Open GL for visualisation, and was developed in a close cooperation with a neurosurgical department to match existing needs. Preoperatively the data may be combined, registered by a rigid or elastic matching process, enriched by user specified planning information such as annotations or trajectories, and visualised in a standard fashion using different segmentation schemes, interactive rotation, zooming etc. Selected portions of the gathered and generated information may then be exported for neuronavigation input in DICOM or a vendor specific format. Intraoperatively, this information may, on the one hand, be simply used as an integrational part of the routinely used navigational data. On the other hand, the system is also capable of interacting with the navigational system to integrate the actual spatial information of the ongoing procedure into the preoperative data, thus allowing further planning and visualisation beyond the scope of the navigational unit. Furthermore, intraoperatively updated information such as intraoperative MR images or electrophysiological data may be integrated and correlated to the existing information. Ongoing developments comprise redistribution of the relevant data for injection onto the screen of the navigational system or into the optical pathway of the (3D capable) microscope display/ocular. This also includes information about the actual automatically optimized accuracy of the navigation process in relation to the head markers in use.