SKSinead Kinsella

Sinead Kinsella

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sinead Kinsella has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of single CT scan assessment of bone mineral density, vascular calcification and fat mass with standard clinical measurements in renal transplant subjects: the ABC HeART study

    by Sinead Kinsella, Kevin Murphy, Micheal Breen, Siobhan O’nEill, Patrick McLaughlin, Joe Coyle, Conor Bogue, Fiona O’nEill, Niamh Moore, AnneMarie McGarrigle, et al.

    Despite limitations of routine methods, Clinical Practice Guidelines support the assessment of bone mineral density (BMD) and vascular calcification in renal transplant recipients. Changes in fat mass also occur post-transplantation, although they are traditionally difficult to measure accurately. We report the feasibility, convenience and accuracy of measuring the above 3 parameters using a novel CT protocol. We conducted a cross-sectional study of 64 first renal allograft recipients (eGFR > 30 ml/min/1.73 m2). Quantitative CT (QCT) BMD analysis was conducted using CT lumbar spine (GE Medical Systems Lightspeed VCT & Mindways QCT Pro Bone Mineral Densitometry System Version 4.2.3) to calculate spinal volumetric BMD and compared with standard DXA calculated areal BMD at the spine, hip and distal forearm. Abdominal aortic calcification was assessed by semi-quantitative Aortic Calcification Index (ACI) method and compared with lateral lumbar x-ray Kappuila score and pulse wave velocity (PWV). Visceral and subcutaneous adipose tissue volume (Osirix 16 Ver 3.7.1) was compared with BMI. Participants were 61 % male, had a mean age of 47 years, median ESKD duration of 5.4 years and a mean eGFR of 54 ml/min. iDXA median T-score at proximal femur was −1.2 and at lumbar spine was −0.2. Median QCT Trabecular T-score at lumbar spine was −1.2. The percent of subjects with a T-score of <2.5 by site and method was DXA Proximal Femur: 7 %, DXA distal radius: 17 %, DXA spine: 9 %, QCT (American College of Radiology cutoffs): 9 %. CT derived ACI correlated with PWV (r = 0.29, p = 0.02), pulse wave pressure (r = 0.51, p < 0.001), QCT Trabecular (−0.31, p = 0.01) and cortical volumetric BMD and history of cardiovascular events (Mann–Whitney U, p = 0.02). Both visceral and subcutaneous adipose tissue correlated with BMI (r = 0.63 & 0.64, p < 0.001). Single CT scan triple assessment of BMD, vascular calcification and body composition is an efficient, accurate and convenient method of risk factor monitoring post renal transplantation.


  • Cumulative ionizing radiation exposure in patients with end stage kidney disease: a 6-year retrospective analysis

    by Joe Coyle, Sinead Kinsella, Siobhain McCarthy, Sebastian MacWilliams, Patrick McLaughlin, Joseph Eustace, Michael M. Maher

    Objective To quantify cumulative exposure to ionizing radiation in patients with end stage kidney disease (ESKD). To investigate factors which may be independently associated with risk of high cumulative effective dose (CED). Materials and methods The study had local institutional review board ethical approval. We conducted a retrospective study of 394 period prevalent ESKD patients attending a single tertiary referral centre between 2004 and 2009. Patient demographics were obtained from case records. Details of radiological investigations were obtained from the institutional radiology computerized database. CED was calculated using standard procedure specific radiation levels. High exposure was defined as CED > 50 mSv, an exposure which has been reported to increase cancer mortality by 5%. Data were compared using Pearson χ2 and Mann–Whitney U test or Kruskal–Wallis tests. Results 394 patients were followed for a median of 4 years (1518 patient years follow-up). Of these 63% were male. Seventeen percent of patients had a CED of >50 mSv. Computed tomography (CT) accounted for 9% of total radiological studies/procedures while contributing 61.4% of total study dose. Median cumulative dose and median dose per patient year were significantly higher in the hemodialysis (HD) group (15.13 and 5.79 mSv, respectively) compared to the post-transplant group (2.9 and 0.52 mSv, respectively) (P < 0.001). Conclusion ESKD patients are at risk of cumulative exposure to significant levels of diagnostic radiation. The majority of this exposure is imparted as a result of CT examinations to patients in the HD group.