Cornelius Keyl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cornelius Keyl has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Annette Schneider
3 shared publicationsA. Schneider
Department of Anesthesiology, University Medical Center, 93042 Regensburg, Germany
2 shared publications- Fabiola León-Velarde
Universidad Peruana Cayetano Heredia
2 shared publications L. Bernardi
Department of Internal Medicine and Institute of Hematology, and
2 shared publicationsLuciano Bernardi
2 shared publicationsMartin Dambacher
2 shared publications
Latest Publications
- 1 January 2003
- Vol. 543, 161-75
Ventilation, autonomic function, sleep and erythropoietin. Chronic mountain sickness of Andean natives.
Polycythemia is one of the key factors involved in the chronic mountain sickness syndrome, a condition frequent in Andean natives but whose causes still remain unclear. In theory, polycythemia may be secondary to abnormalities in ventilation, occurring during day or night (e.g. due to sleep abnormalities) stimulating excessive erythropoietin (Epo) production, or else it may result from either autogenous production, or from co-factors like cobalt. To assess the importance of these points, we studied subjects with or without polycythemia, born and living in Cerro de Pasco (Peru, 4330m asl, CP) and evaluated the relationship between Epo and respiratory variables both in CP and sea level. We also assessed the relationship between sleep abnormalities and the circadian rhythm of Epo. Polycythemic subjects showed higher Epo in all conditions, lower SaO2 and hypoxic ventilatory response, higher physiological dead space and higher CO2, suggesting ventilatory inefficiency. Epo levels could be highly modified by the level of oxygenation, and were related to similar directional changes in SaO2. Cobalt levels were normal in all subjects and correlated poorly with hematologic variables. The diurnal variations in Epo were grossly abnormal in polycythemic subjects, with complete loss of the circadian rhythm. These abnormalities correlated with the levels of hypoxemia during the night, but not with sleep abnormalities, which were only minor even in polycythemic subjects. The increased Epo production is mainly related to a greater ventilatory inefficiency, and not to altered sensitivity to hypoxia, cobalt or sleep abnormalities. Improving oxygenation can represent a possible therapeutic option for this syndrome.
- 1 January 2003
- Vol. 543, 161-75
Ventilation, autonomic function, sleep and erythropoietin. Chronic mountain sickness of Andean natives.
Polycythemia is one of the key factors involved in the chronic mountain sickness syndrome, a condition frequent in Andean natives but whose causes still remain unclear. In theory, polycythemia may be secondary to abnormalities in ventilation, occurring during day or night (e.g. due to sleep abnormalities) stimulating excessive erythropoietin (Epo) production, or else it may result from either autogenous production, or from co-factors like cobalt. To assess the importance of these points, we studied subjects with or without polycythemia, born and living in Cerro de Pasco (Peru, 4330m asl, CP) and evaluated the relationship between Epo and respiratory variables both in CP and sea level. We also assessed the relationship between sleep abnormalities and the circadian rhythm of Epo. Polycythemic subjects showed higher Epo in all conditions, lower SaO2 and hypoxic ventilatory response, higher physiological dead space and higher CO2, suggesting ventilatory inefficiency. Epo levels could be highly modified by the level of oxygenation, and were related to similar directional changes in SaO2. Cobalt levels were normal in all subjects and correlated poorly with hematologic variables. The diurnal variations in Epo were grossly abnormal in polycythemic subjects, with complete loss of the circadian rhythm. These abnormalities correlated with the levels of hypoxemia during the night, but not with sleep abnormalities, which were only minor even in polycythemic subjects. The increased Epo production is mainly related to a greater ventilatory inefficiency, and not to altered sensitivity to hypoxia, cobalt or sleep abnormalities. Improving oxygenation can represent a possible therapeutic option for this syndrome.
- 1 January 2003
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 94 (1) , 213-219
Autonomic cardiovascular function in high-altitude Andean natives with chronic mountain sickness
We evaluated autonomic cardiovascular regulation in subjects with polycythemia and chronic mountain sickness (CMS) and tested the hypothesis that an increase in arterial oxygen saturation has a beneficial effect on arterial baroreflex sensitivity in these subjects. Ten Andean natives with a Hct >65% and 10 natives with a Hct 65% showed an increased incidence of CMS compared with subjects with Hct <60%. Spontaneous baroreflex sensitivity was significantly lower in subjects with high Hct compared with the control group. The effects of supplemental oxygen or modification of the breathing pattern on autonomic function were as follows: 1) heart rate decreased significantly after both maneuvers in both groups, and 2) spontaneous baroreflex sensitivity increased significantly in subjects with high Hct and did not differ from subjects with low Hct. Temporary slow-frequency breathing may provide a beneficial effect on the autonomic cardiovascular function in high-altitude natives with CMS.
- 1 January 2003
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 94 (1) , 213-219
Autonomic cardiovascular function in high-altitude Andean natives with chronic mountain sickness
We evaluated autonomic cardiovascular regulation in subjects with polycythemia and chronic mountain sickness (CMS) and tested the hypothesis that an increase in arterial oxygen saturation has a beneficial effect on arterial baroreflex sensitivity in these subjects. Ten Andean natives with a Hct >65% and 10 natives with a Hct 65% showed an increased incidence of CMS compared with subjects with Hct <60%. Spontaneous baroreflex sensitivity was significantly lower in subjects with high Hct compared with the control group. The effects of supplemental oxygen or modification of the breathing pattern on autonomic function were as follows: 1) heart rate decreased significantly after both maneuvers in both groups, and 2) spontaneous baroreflex sensitivity increased significantly in subjects with high Hct and did not differ from subjects with low Hct. Temporary slow-frequency breathing may provide a beneficial effect on the autonomic cardiovascular function in high-altitude natives with CMS.
- 1 July 2001
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 91 (1) , 283-289
Time delay of vagally mediated cardiac baroreflex response varies with autonomic cardiovascular control
To examine whether changes in autonomic activity have an effect on the latency of the vagally mediated cardiac baroreflex response in humans, we investigated the effects of neck suction fluctuating sinusoidally at 0.2 Hz on R-R intervals (known to be mediated mainly by vagal activity) in the supine position, during 15° head-down tilt and 60° head-up tilt, and during vagotonic (2 μg/kg) and vagolytic (10 μg/kg) doses of atropine while the subjects breathed at 0.25 Hz. The phase shift between fluctuations in neck chamber pressure and in R-R interval was calculated by complex transfer function analysis and was used as a measure of the time delay between carotid baroreceptor stimulation and cardiac effector response. Cardiac baroreflex responsiveness increased significantly during low-dose atropine and decreased during head-up tilt or 10 μg/kg atropine. With increasing tilt angle, the time delay between cyclic baroreceptor stimulation and oscillations in R-R interval increased from 0.32 ± 0.27 s (head down), to 0.59 ± 0.25 s (supine position, P < 0.05 vs. head down), and to 0.86 ± 0.27 s (head up,P < 0.01 vs. supine). Low-dose atropine had a similar effect to head-down tilt on baroreflex latency, whereas 10 μg/kg atropine increased the time delay markedly to 1.24 ± 0.30 s. Our results demonstrate that changes in autonomic activity, generated either by gravitational stimulus or by atropine, not only affect baroreflex responsiveness but also have a major influence on the latency of the vagally mediated carotid baroreceptor-heart rate reflex. The prolonged baroreflex latency during decreased parasympathetic function may contribute to an unstable regulation of heart rate in patients with cardiac disease.
- 1 July 2001
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 91 (1) , 283-289
Time delay of vagally mediated cardiac baroreflex response varies with autonomic cardiovascular control
To examine whether changes in autonomic activity have an effect on the latency of the vagally mediated cardiac baroreflex response in humans, we investigated the effects of neck suction fluctuating sinusoidally at 0.2 Hz on R-R intervals (known to be mediated mainly by vagal activity) in the supine position, during 15° head-down tilt and 60° head-up tilt, and during vagotonic (2 μg/kg) and vagolytic (10 μg/kg) doses of atropine while the subjects breathed at 0.25 Hz. The phase shift between fluctuations in neck chamber pressure and in R-R interval was calculated by complex transfer function analysis and was used as a measure of the time delay between carotid baroreceptor stimulation and cardiac effector response. Cardiac baroreflex responsiveness increased significantly during low-dose atropine and decreased during head-up tilt or 10 μg/kg atropine. With increasing tilt angle, the time delay between cyclic baroreceptor stimulation and oscillations in R-R interval increased from 0.32 ± 0.27 s (head down), to 0.59 ± 0.25 s (supine position, P < 0.05 vs. head down), and to 0.86 ± 0.27 s (head up,P < 0.01 vs. supine). Low-dose atropine had a similar effect to head-down tilt on baroreflex latency, whereas 10 μg/kg atropine increased the time delay markedly to 1.24 ± 0.30 s. Our results demonstrate that changes in autonomic activity, generated either by gravitational stimulus or by atropine, not only affect baroreflex responsiveness but also have a major influence on the latency of the vagally mediated carotid baroreceptor-heart rate reflex. The prolonged baroreflex latency during decreased parasympathetic function may contribute to an unstable regulation of heart rate in patients with cardiac disease.
- 1 November 2000
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 91 (5) , 1188-1195
Dynamic Cardiocirculatory Control During Propofol Anesthesia in Mechanically Ventilated Patients
We evaluated dynamic cardiovascular control by spectral analytical methods in 20 young adults anesthetized with propofol (2.5 mg/kg, followed by continuous infusion of 0.1 mg/kg/min) and in an awake control group during cyclic stimulation of the carotid baroreceptors via sinusoidal neck suction at 0.2 Hz (baroreflex response mediated mainly by vagal activity) and at 0.1 Hz (baroreflex response mediated by vagal and sympathetic activity). During anesthesia and mechanical ventilation at 0.25 Hz, major underdampened hemodynamic oscillations occurred at 0.055 +/- 0.012 Hz. The response of RR intervals to baroreceptor stimulation at 0.2 Hz was markedly decreased during anesthesia (median of transfer function magnitude between neck suction and RR intervals 3% of the awake control). Blood pressure response to baroreceptor stimulation at 0.1 Hz was significantly decreased during anesthesia to 26% (systolic blood pressure), and 44% (diastolic blood pressure) of the awake control. There was a significant delay in baroreflex effector responses during anesthesia. Our results demonstrate a markedly depressed vagally mediated heart rate response and an impaired blood pressure response to cyclic baroreceptor stimulation during propofol anesthesia in mechanically ventilated patients. The disturbed baroreflex control is accompanied by an irregular dynamic behavior of cardiovascular regulation, indicating a decreased stability of the control system. An irregular dynamic behavior of the cardiovascular control system, associated with an impaired baroreflex control of heart rate and blood pressure, can be observed during propofol anesthesia in mechanically ventilated subjects.
- 1 November 2000
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 91 (5) , 1188-1195
Dynamic Cardiocirculatory Control During Propofol Anesthesia in Mechanically Ventilated Patients
We evaluated dynamic cardiovascular control by spectral analytical methods in 20 young adults anesthetized with propofol (2.5 mg/kg, followed by continuous infusion of 0.1 mg/kg/min) and in an awake control group during cyclic stimulation of the carotid baroreceptors via sinusoidal neck suction at 0.2 Hz (baroreflex response mediated mainly by vagal activity) and at 0.1 Hz (baroreflex response mediated by vagal and sympathetic activity). During anesthesia and mechanical ventilation at 0.25 Hz, major underdampened hemodynamic oscillations occurred at 0.055 +/- 0.012 Hz. The response of RR intervals to baroreceptor stimulation at 0.2 Hz was markedly decreased during anesthesia (median of transfer function magnitude between neck suction and RR intervals 3% of the awake control). Blood pressure response to baroreceptor stimulation at 0.1 Hz was significantly decreased during anesthesia to 26% (systolic blood pressure), and 44% (diastolic blood pressure) of the awake control. There was a significant delay in baroreflex effector responses during anesthesia. Our results demonstrate a markedly depressed vagally mediated heart rate response and an impaired blood pressure response to cyclic baroreceptor stimulation during propofol anesthesia in mechanically ventilated patients. The disturbed baroreflex control is accompanied by an irregular dynamic behavior of cardiovascular regulation, indicating a decreased stability of the control system. An irregular dynamic behavior of the cardiovascular control system, associated with an impaired baroreflex control of heart rate and blood pressure, can be observed during propofol anesthesia in mechanically ventilated subjects.
- 10 July 2000
- Published by Portland Press Ltd. in Clinical Science
- Vol. 99 (2) , 113-124
Cardiocirculatory coupling during sinusoidal baroreceptor stimulation and fixed-frequency breathing
The question of whether respiratory sinus arrhythmia (RSA) originates mainly from a central coupling between respiration and heart rate, or from baroreflex mechanisms, is a subject of controversy. If there is a major contribution of baroreflexes to RSA, cardiocirculatory coupling during breathing and during cyclic baroreflex stimulation should show similarities. We applied a sinusoidal stimulus to the carotid baroreceptors and generated heart rate fluctuations of the same magnitude as RSA with a frequency similar to, but different from, the breathing frequency (0.2 Hz, compared with 0.25 Hz), and at 0.1 Hz, in 17 supine healthy subjects (age 28–39 years). The data were analysed using discrete Fourier-transform and transfer function analysis. Respiratory fluctuations in systolic blood pressure preceded RSA with a time lag equal to that between baroreceptor stimulation and oscillations in RR interval (0.62±0.18 s compared with 0.57±0.28 s at 0.2 Hz neck suction). The response of systolic blood pressure to neck suction at 0.2 Hz was 5 times less than the respiratory blood pressure fluctuations. Neck suction at 0.1 Hz largely increased fluctuations in blood pressure and RR interval, whereas the spontaneous phase relationship between blood pressure and RR interval remained unchanged. Our results are not consistent with the hypothesis that the origin of RSA is predominantly a central phenomenon which secondarily generates fluctuations in blood pressure, but suggest that, under the condition of fixed-frequency breathing at 0.25 Hz, baroreflex mechanisms contribute to respiratory fluctuations in RR interval.
- 10 July 2000
- Published by Portland Press Ltd. in Clinical Science
- Vol. 99 (2) , 113-124
Cardiocirculatory coupling during sinusoidal baroreceptor stimulation and fixed-frequency breathing
The question of whether respiratory sinus arrhythmia (RSA) originates mainly from a central coupling between respiration and heart rate, or from baroreflex mechanisms, is a subject of controversy. If there is a major contribution of baroreflexes to RSA, cardiocirculatory coupling during breathing and during cyclic baroreflex stimulation should show similarities. We applied a sinusoidal stimulus to the carotid baroreceptors and generated heart rate fluctuations of the same magnitude as RSA with a frequency similar to, but different from, the breathing frequency (0.2 Hz, compared with 0.25 Hz), and at 0.1 Hz, in 17 supine healthy subjects (age 28–39 years). The data were analysed using discrete Fourier-transform and transfer function analysis. Respiratory fluctuations in systolic blood pressure preceded RSA with a time lag equal to that between baroreceptor stimulation and oscillations in RR interval (0.62±0.18 s compared with 0.57±0.28 s at 0.2 Hz neck suction). The response of systolic blood pressure to neck suction at 0.2 Hz was 5 times less than the respiratory blood pressure fluctuations. Neck suction at 0.1 Hz largely increased fluctuations in blood pressure and RR interval, whereas the spontaneous phase relationship between blood pressure and RR interval remained unchanged. Our results are not consistent with the hypothesis that the origin of RSA is predominantly a central phenomenon which secondarily generates fluctuations in blood pressure, but suggest that, under the condition of fixed-frequency breathing at 0.25 Hz, baroreflex mechanisms contribute to respiratory fluctuations in RR interval.