Dominik Parsch
Research Subjects
Dominik Parsch has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
M. Zimmermann-Stenzel
Orthopädische Universitätsklinik, Heidelberg, Deutschland
2 shared publications- Boris Michael Holzapfel
Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany
1 shared publication C. Rau
Orthopädische Universitätsklinik, Heidelberg, Deutschland
1 shared publication- Christian Heisel
ARCUS-Sportklinik
1 shared publication - Florian Geiger
Department of Orthopaedic Surgery, University of Heidelberg, Heidelberg, Germany
1 shared publication - Günther Zeiler
Wichernhaus am Krankenhaus Rummelsberg
1 shared publication
Latest Publications
- 13 March 2008
- Published by Springer Nature in Der Orthopäde
- Vol. 37 (4) , 374-380
Beurteilung des Verfahrens der Knieendoprothetik durch deutsche Hausärzte
- 13 March 2008
- Published by Springer Nature in Der Orthopäde
- Vol. 37 (4) , 374-380
Beurteilung des Verfahrens der Knieendoprothetik durch deutsche Hausärzte
- 27 September 2007
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 128 (3) , 267-270
Intraoperative assessment of femoral component rotational alignment in total knee arthroplasty
Poor clinical results following total knee arthroplasty like flexion gap instability or anterior knee pain may be related to femoral component rotational malalignment. The transepicondylar axis has been recommended as a landmark to consistently recreate a balanced flexion gap. However, the reproducibility to identify the transepicondylar axis intraoperatively is low. In this feasibility study we wanted to find out whether fluoroscopy-based CT scans obtained by a motorized mobile C-arm (Iso C 3D) may be useful to asses the transepicondylar axis intraoperatively. Following the femoral resections the Iso C 3D was used intraoperatively in ten knees with mild to severe deformities. On multiplanar reconstructions of the distal femur the clinical epicondylar axis as well as the angle to the posterior cut (condylar twist angle) could be easily measured. The scanning time was 40 s and the extra time needed for the whole setup about five to ten minutes. The Iso C 3D was helpful to intraoperatively identify the transepicondylar axis and the condylar twist angle, especially in cases with severe deformity or dysplasia when standard landmarks are difficult to determine.
- 27 September 2007
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 128 (3) , 267-270
Intraoperative assessment of femoral component rotational alignment in total knee arthroplasty
Poor clinical results following total knee arthroplasty like flexion gap instability or anterior knee pain may be related to femoral component rotational malalignment. The transepicondylar axis has been recommended as a landmark to consistently recreate a balanced flexion gap. However, the reproducibility to identify the transepicondylar axis intraoperatively is low. In this feasibility study we wanted to find out whether fluoroscopy-based CT scans obtained by a motorized mobile C-arm (Iso C 3D) may be useful to asses the transepicondylar axis intraoperatively. Following the femoral resections the Iso C 3D was used intraoperatively in ten knees with mild to severe deformities. On multiplanar reconstructions of the distal femur the clinical epicondylar axis as well as the angle to the posterior cut (condylar twist angle) could be easily measured. The scanning time was 40 s and the extra time needed for the whole setup about five to ten minutes. The Iso C 3D was helpful to intraoperatively identify the transepicondylar axis and the condylar twist angle, especially in cases with severe deformity or dysplasia when standard landmarks are difficult to determine.
- 2 August 2007
- Published by Springer Nature in Der Orthopäde
- Vol. 36 (10) , 957-962
Beurteilung des Verfahrens Hüftendoprothetik durch deutsche Hausärzte
To assess the general knowledge and individual views of general practitioners (GPs) on total hip arthroplasty (THA), we performed a questionnaire-based survey involving 200 GPs in Germany.Ninety-four GPs returned the questionnaire. They had treated a mean of 37.7+/-38.6 patients (range 0-300) with THA. Their general knowledge can be estimated as good. They assessed the potential for complications in association with THA as higher than that reported in the literature. If the GPs had been exposed to more complications in their practices, they estimated a lower patient satisfaction rate 10 years after surgery and were less satisfied with the indications given by their operating colleagues.A broad spectrum of individual responses indicates the need to improve information transfer between orthopaedic surgeons and referring GPs.
- 2 August 2007
- Published by Springer Nature in Der Orthopäde
- Vol. 36 (10) , 957-962
Beurteilung des Verfahrens Hüftendoprothetik durch deutsche Hausärzte
To assess the general knowledge and individual views of general practitioners (GPs) on total hip arthroplasty (THA), we performed a questionnaire-based survey involving 200 GPs in Germany.Ninety-four GPs returned the questionnaire. They had treated a mean of 37.7+/-38.6 patients (range 0-300) with THA. Their general knowledge can be estimated as good. They assessed the potential for complications in association with THA as higher than that reported in the literature. If the GPs had been exposed to more complications in their practices, they estimated a lower patient satisfaction rate 10 years after surgery and were less satisfied with the indications given by their operating colleagues.A broad spectrum of individual responses indicates the need to improve information transfer between orthopaedic surgeons and referring GPs.