JLJia-Min Lin

Jia-Min Lin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jia-Min Lin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Building-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds

    by Chung-Yen Lu, Jia-Min Lin, Ying-Yi Chen, Yi-Chun Chen

    This study investigated whether sick building syndrome (SBS) complaints among office workers were associated with the indoor air quality. With informed consent, 417 employees in 87 office rooms of eight high-rise buildings completed a self-reported questionnaire for symptoms experienced at work during the past month. Carbon dioxide (CO2), temperature, humidity and total volatile organic compounds (TVOCs) in each office were simultaneously measured for eight office hours using portable monitors. Time-averaged workday difference between the indoor and the outdoor CO2 concentrations (dCO2) was calculated as a surrogate measure of ventilation efficiency for each office unit. The prevalence rates of SBS were 22.5% for eye syndrome, 15.3% for upper respiratory and 25.4% for non-specific syndromes. Tiredness (20.9%), difficulty in concentrating (14.6%), eye dryness (18.7%) were also common complaints. The generalized estimating equations multivariate logistic regression analyses showed that adjusted odds ratios (aORs) and 95% confidence interval (CI) per 100 ppm increase in dCO2 were significantly associated with dry throat (1.10, 95% CI = (1.00–1.22)), tiredness (1.16, 95% CI = (1.04–1.29)) and dizziness (1.22, 95% CI = (1.08–1.37)). The ORs for per 100 ppb increases in TVOCs were also associated with upper respiratory symptoms (1.06, 95% CI = (1.04–1.07)), dry throat (1.06, 95% CI = (1.03–1.09)) and irritability (1.02, 95% CI = (1.01–1.04)). In conclusion, the association between some SBS symptoms and the exposure to CO2 and total VOCs are moderate but may be independently significant.


  • Determination of Particulate-Bound Formaldehyde from Burning Incense by Solid Phase Microextraction

    by S. W. Liou, C. Y. Chen, T. T. Yang, J. M. Lin

    This work studied the feasibility of using a solid phase microextraction (SPME) fiber for sampling and analysis of gaseous formaldehyde as well as particulate-bound formaldehyde from burning Chinese incense. The SPME fiber with PDMS/DVB coating were partially coated with o-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine hydrochloride (PFBHA), and used for sampling formaldehyde. The sampling rate for formaldehyde and its dependence on temperature, relative humidity and sampling time were observed. The same PFBHA treated fibers were, in parallel, exposed to incense burning smoke with pre-filtration and without pre- filtration for 0.5–1 min. The NIOSH method 2541 using an XAD-2 tube at a flow rate of 0.1 Lpm was also applied for sampling simultaneously. The results demonstrate that commercially available PDMS/DVB fibers partially coated with PFBHA are capable of sampling the gas phase of formaldehyde as well as particulate-bound formaldehyde. The determined level of formaldehyde was close to the result obtained by the NIOSH method 2541. However, a reduction of the fiber’s formaldehyde loading capacity in the aerosol sampling in comparison with gas sampling was noticed. This indicates that the particulate characteristics, and their bound chemicals other than formaldehyde may influence the maximum loading capacity of formaldehyde, and some characteristic particulates in high concentrations may even deteriorate the fiber coating.