Jia-Min Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jia-Min Lin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
C. Y. Chen
Institute of Occupational Safety and Health, Sijhih City, Taiwan, ROC
1 shared publication- Chung-Yen Lu
Department of Sport and Health Management, Da-Yeh University, Changhua 515, Taiwan
1 shared publication S. W. Liou
Institute of Environmental Health, National Taiwan University, Taipei, 10055, Taiwan, Republic of China
1 shared publicationT. T. Yang
Department of Environmental Engineering and Health, Yuanpei University of Science and Technology, Hsin Chu, Taiwan, ROC
1 shared publication- Yi-Chun Chen
Department of Health Management, I-Shou University, Kaohsiung, Taiwan
1 shared publication - Ying-Yi Chen
Institute of Environmental and Occupational Health Sciences, National Yang-Ming University, Taipei 100, Taiwan
1 shared publication
Latest Publications
- Open Access
- 27 May 2015
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 12 (6) , 5833-5845
Building-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds
This study investigated whether sick building syndrome (SBS) complaints among office workers were associated with the indoor air quality. With informed consent, 417 employees in 87 office rooms of eight high-rise buildings completed a self-reported questionnaire for symptoms experienced at work during the past month. Carbon dioxide (CO2), temperature, humidity and total volatile organic compounds (TVOCs) in each office were simultaneously measured for eight office hours using portable monitors. Time-averaged workday difference between the indoor and the outdoor CO2 concentrations (dCO2) was calculated as a surrogate measure of ventilation efficiency for each office unit. The prevalence rates of SBS were 22.5% for eye syndrome, 15.3% for upper respiratory and 25.4% for non-specific syndromes. Tiredness (20.9%), difficulty in concentrating (14.6%), eye dryness (18.7%) were also common complaints. The generalized estimating equations multivariate logistic regression analyses showed that adjusted odds ratios (aORs) and 95% confidence interval (CI) per 100 ppm increase in dCO2 were significantly associated with dry throat (1.10, 95% CI = (1.00–1.22)), tiredness (1.16, 95% CI = (1.04–1.29)) and dizziness (1.22, 95% CI = (1.08–1.37)). The ORs for per 100 ppb increases in TVOCs were also associated with upper respiratory symptoms (1.06, 95% CI = (1.04–1.07)), dry throat (1.06, 95% CI = (1.03–1.09)) and irritability (1.02, 95% CI = (1.01–1.04)). In conclusion, the association between some SBS symptoms and the exposure to CO2 and total VOCs are moderate but may be independently significant.
- 27 May 2015
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 12 (6) , 5833-5845
Open AccessBuilding-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds
This study investigated whether sick building syndrome (SBS) complaints among office workers were associated with the indoor air quality. With informed consent, 417 employees in 87 office rooms of eight high-rise buildings completed a self-reported questionnaire for symptoms experienced at work during the past month. Carbon dioxide (CO2), temperature, humidity and total volatile organic compounds (TVOCs) in each office were simultaneously measured for eight office hours using portable monitors. Time-averaged workday difference between the indoor and the outdoor CO2 concentrations (dCO2) was calculated as a surrogate measure of ventilation efficiency for each office unit. The prevalence rates of SBS were 22.5% for eye syndrome, 15.3% for upper respiratory and 25.4% for non-specific syndromes. Tiredness (20.9%), difficulty in concentrating (14.6%), eye dryness (18.7%) were also common complaints. The generalized estimating equations multivariate logistic regression analyses showed that adjusted odds ratios (aORs) and 95% confidence interval (CI) per 100 ppm increase in dCO2 were significantly associated with dry throat (1.10, 95% CI = (1.00–1.22)), tiredness (1.16, 95% CI = (1.04–1.29)) and dizziness (1.22, 95% CI = (1.08–1.37)). The ORs for per 100 ppb increases in TVOCs were also associated with upper respiratory symptoms (1.06, 95% CI = (1.04–1.07)), dry throat (1.06, 95% CI = (1.03–1.09)) and irritability (1.02, 95% CI = (1.01–1.04)). In conclusion, the association between some SBS symptoms and the exposure to CO2 and total VOCs are moderate but may be independently significant.
- 17 March 2008
- Published by Springer Nature in Bulletin of Environmental Contamination and Toxicology
- Vol. 80 (4) , 324-328
Determination of Particulate-Bound Formaldehyde from Burning Incense by Solid Phase Microextraction
This work studied the feasibility of using a solid phase microextraction (SPME) fiber for sampling and analysis of gaseous formaldehyde as well as particulate-bound formaldehyde from burning Chinese incense. The SPME fiber with PDMS/DVB coating were partially coated with o-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine hydrochloride (PFBHA), and used for sampling formaldehyde. The sampling rate for formaldehyde and its dependence on temperature, relative humidity and sampling time were observed. The same PFBHA treated fibers were, in parallel, exposed to incense burning smoke with pre-filtration and without pre- filtration for 0.5–1 min. The NIOSH method 2541 using an XAD-2 tube at a flow rate of 0.1 Lpm was also applied for sampling simultaneously. The results demonstrate that commercially available PDMS/DVB fibers partially coated with PFBHA are capable of sampling the gas phase of formaldehyde as well as particulate-bound formaldehyde. The determined level of formaldehyde was close to the result obtained by the NIOSH method 2541. However, a reduction of the fiber’s formaldehyde loading capacity in the aerosol sampling in comparison with gas sampling was noticed. This indicates that the particulate characteristics, and their bound chemicals other than formaldehyde may influence the maximum loading capacity of formaldehyde, and some characteristic particulates in high concentrations may even deteriorate the fiber coating.
- 17 March 2008
- Published by Springer Nature in Bulletin of Environmental Contamination and Toxicology
- Vol. 80 (4) , 324-328
Determination of Particulate-Bound Formaldehyde from Burning Incense by Solid Phase Microextraction
This work studied the feasibility of using a solid phase microextraction (SPME) fiber for sampling and analysis of gaseous formaldehyde as well as particulate-bound formaldehyde from burning Chinese incense. The SPME fiber with PDMS/DVB coating were partially coated with o-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine hydrochloride (PFBHA), and used for sampling formaldehyde. The sampling rate for formaldehyde and its dependence on temperature, relative humidity and sampling time were observed. The same PFBHA treated fibers were, in parallel, exposed to incense burning smoke with pre-filtration and without pre- filtration for 0.5–1 min. The NIOSH method 2541 using an XAD-2 tube at a flow rate of 0.1 Lpm was also applied for sampling simultaneously. The results demonstrate that commercially available PDMS/DVB fibers partially coated with PFBHA are capable of sampling the gas phase of formaldehyde as well as particulate-bound formaldehyde. The determined level of formaldehyde was close to the result obtained by the NIOSH method 2541. However, a reduction of the fiber’s formaldehyde loading capacity in the aerosol sampling in comparison with gas sampling was noticed. This indicates that the particulate characteristics, and their bound chemicals other than formaldehyde may influence the maximum loading capacity of formaldehyde, and some characteristic particulates in high concentrations may even deteriorate the fiber coating.