Henrik Behrend
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Henrik Behrend has a total of 112 co-authors. Here are the top co-authors by number of shared publications:
Bettina Hochreiter
Department of Orthopaedic Surgery and Traumatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
6 shared publicationsVilijam Zdravkovic
<!--1--> Department of Orthopaedic Surgery and Traumatology Kantonsspital St. Gallen Rorschacherstrasse 95 CH‐9007 St. Gallen Switzerland
6 shared publicationsMichael T. Hirschmann
Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), 4101, Bruderholz, Switzerland
5 shared publicationsAndreas Ladurner
<!--1--> Department of Orthopaedic Surgery and Traumatology Kantonsspital St. Gallen Rorschacherstrasse 95 CH‐9007 St. Gallen Switzerland
3 shared publicationsFelix Amsler
<!--4--> Amsler Consulting Basel Switzerland
3 shared publications- Felix Amsler
Amsler Consulting Basel Switzerland
3 shared publications
Latest Publications
- Open Access
- 26 September 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (2) , 407-418
Osteoarthritic and non‐osteoarthritic patients show comparable coronal knee joint line orientations in a cross‐sectional study based on 3D reconstructed CT images
Purpose: Recently introduced total knee arthroplasty (TKA) alignment strategies aim to restore the pre‐arthritic alignment of an individual patient. The native alignment of a patient can only be restored with detailed knowledge about the native and osteoarthritic alignment as well as differences between them. The first aim of this study was to assess the alignment of a large series of osteoarthritic (OA) knees and investigate whether femoral and tibial joint lines vary within patients with the same overall lower limb alignment. The secondary aim was to compare the alignment of OA patients to the previously published data of non‐OA patients. This information could be useful for surgeons considering implementing one of the new alignment concepts.Material: Coronal alignment parameters of 2692 knee OA patients were measured based on 3D reconstructed CT data using a validated planning software (Knee‐PLAN®, Symbios, Yverdon les Bains, Switzerland). Based on these measurements, patients' coronal alignment was phenotyped according to the functional knee phenotype concept. These phenotypes represent an alignment variation of either the overall alignment, the femoral joint line orientation or the tibial joint line orientation. Each phenotype is defined by a specific mean and covers a range of ± 1.5° from this mean. Mean values and distribution among the phenotypes are presented and compared between two populations (OA patients of this study and non‐OA patients of a previously published study) as well as between HKA subgroups (varus, valgus and neutral) using t tests and Chi‐square tests (p < 0.05).Results: Femoral and tibial joint lines varied within patients with the same overall lower limb alignment. A total of 162 functional knee phenotypes were found (119 males, 136 females and 94 mutual phenotypes). Mean values differed between the OA and non‐OA population, but differences were small (< 2°) except for the overall alignment (e.g. HKA). The distribution of OA and non‐OA patients among the phenotypes differed significantly, especially among the limb phenotypes.Conclusion: Differences between OA and non‐OA knees are small regarding coronal femoral and tibial joint line orientation. Femoral and tibial joint line orientation of osteoarthritic patients can, therefore, be used to estimate their native coronal alignment and plan an individualized knee alignment.Level of clinical evidence: III.
- 26 September 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (2) , 407-418
Open AccessOsteoarthritic and non‐osteoarthritic patients show comparable coronal knee joint line orientations in a cross‐sectional study based on 3D reconstructed CT images
Purpose: Recently introduced total knee arthroplasty (TKA) alignment strategies aim to restore the pre‐arthritic alignment of an individual patient. The native alignment of a patient can only be restored with detailed knowledge about the native and osteoarthritic alignment as well as differences between them. The first aim of this study was to assess the alignment of a large series of osteoarthritic (OA) knees and investigate whether femoral and tibial joint lines vary within patients with the same overall lower limb alignment. The secondary aim was to compare the alignment of OA patients to the previously published data of non‐OA patients. This information could be useful for surgeons considering implementing one of the new alignment concepts.Material: Coronal alignment parameters of 2692 knee OA patients were measured based on 3D reconstructed CT data using a validated planning software (Knee‐PLAN®, Symbios, Yverdon les Bains, Switzerland). Based on these measurements, patients' coronal alignment was phenotyped according to the functional knee phenotype concept. These phenotypes represent an alignment variation of either the overall alignment, the femoral joint line orientation or the tibial joint line orientation. Each phenotype is defined by a specific mean and covers a range of ± 1.5° from this mean. Mean values and distribution among the phenotypes are presented and compared between two populations (OA patients of this study and non‐OA patients of a previously published study) as well as between HKA subgroups (varus, valgus and neutral) using t tests and Chi‐square tests (p < 0.05).Results: Femoral and tibial joint lines varied within patients with the same overall lower limb alignment. A total of 162 functional knee phenotypes were found (119 males, 136 females and 94 mutual phenotypes). Mean values differed between the OA and non‐OA population, but differences were small (< 2°) except for the overall alignment (e.g. HKA). The distribution of OA and non‐OA patients among the phenotypes differed significantly, especially among the limb phenotypes.Conclusion: Differences between OA and non‐OA knees are small regarding coronal femoral and tibial joint line orientation. Femoral and tibial joint line orientation of osteoarthritic patients can, therefore, be used to estimate their native coronal alignment and plan an individualized knee alignment.Level of clinical evidence: III.
- 21 August 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (2) , 389-396
Tibial joint line orientation has no effect on joint awareness after mechanically aligned total knee arthroplasty
Purpose: Joint line orientation (JLO) plays an important role in total knee arthroplasty (TKA), but its influence on patient‐reported outcomes (PROs) is unclear. The purpose of this study was to examine JLO impact as measured by the forgotten joint score (FJS‐12). The hypothesis was that restoring the joint line (JL) parallel to the floor would influence joint awareness favorably, i.e., allow the patient to forget about the joint in daily living.Methods: All computer‐navigated primary TKAs using a cemented, cruciate‐retaining (CR) design implanted between January 2018 and September 2019 were reviewed in this retrospective single‐center analysis. Primary endpoints were: clinical [range of motion (ROM)], and patient‐reported (FJS‐12) and radiographical outcomes [tibia joint line angle (TJLA), hip knee axis (HKA), mechanical medial proximal tibia angle (mMPTA) as well as mechanical lateral distal femoral angle (mLDFA)].Results: Seventy‐six patients (mean age: 70.3 ± 9.7 years, mean BMI: 29.7 ± 5.2 kg/m2) were included. Postoperative ROM averaged 118.7 ± 9.6°. The mean FJS‐12 improved from 16.4 ± 15.3 (preoperatively) to 89.4 ± 16.9 (1‐year follow‐up; p < 0.001). Clinical outcomes and PROs did not correlate with JLO (p = n.s.). Cluster analysis using six measures revealed that a medially opened TJLA was associated with significantly better postoperative FJS‐12.Conclusion: Tibial JLO was found to have no effect on PROs. Considering the JLO in the coronal plane alone probably has questionable clinical relevance. Lower limb alignment should be assessed in all three planes and correlated with the clinical outcome.Level of clinical evidence: Level IV.
- 21 August 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (2) , 389-396
Tibial joint line orientation has no effect on joint awareness after mechanically aligned total knee arthroplasty
Purpose: Joint line orientation (JLO) plays an important role in total knee arthroplasty (TKA), but its influence on patient‐reported outcomes (PROs) is unclear. The purpose of this study was to examine JLO impact as measured by the forgotten joint score (FJS‐12). The hypothesis was that restoring the joint line (JL) parallel to the floor would influence joint awareness favorably, i.e., allow the patient to forget about the joint in daily living.Methods: All computer‐navigated primary TKAs using a cemented, cruciate‐retaining (CR) design implanted between January 2018 and September 2019 were reviewed in this retrospective single‐center analysis. Primary endpoints were: clinical [range of motion (ROM)], and patient‐reported (FJS‐12) and radiographical outcomes [tibia joint line angle (TJLA), hip knee axis (HKA), mechanical medial proximal tibia angle (mMPTA) as well as mechanical lateral distal femoral angle (mLDFA)].Results: Seventy‐six patients (mean age: 70.3 ± 9.7 years, mean BMI: 29.7 ± 5.2 kg/m2) were included. Postoperative ROM averaged 118.7 ± 9.6°. The mean FJS‐12 improved from 16.4 ± 15.3 (preoperatively) to 89.4 ± 16.9 (1‐year follow‐up; p < 0.001). Clinical outcomes and PROs did not correlate with JLO (p = n.s.). Cluster analysis using six measures revealed that a medially opened TJLA was associated with significantly better postoperative FJS‐12.Conclusion: Tibial JLO was found to have no effect on PROs. Considering the JLO in the coronal plane alone probably has questionable clinical relevance. Lower limb alignment should be assessed in all three planes and correlated with the clinical outcome.Level of clinical evidence: Level IV.
- 1 December 2020
- Published by Hogrefe Publishing Group in Therapeutische Umschau
- Vol. 77 (10) , 469-474
When should we perform a knee or hip arthroplasty?
Total hip (THA) and knee arthroptasties (TKA) rank among the most successful and effective orthopedic operations. They improve health-related quality of life and result in high patient satisfaction. But when is the right moment to perform an arthroplasty? A differentiated indication is decisive for a good outcome. Pain, limitations in quality of life because of osteoarthritis, radiological confirmation of osteoarthritis and inadequate response to conservative treatment should be reported. Moreover, medical history, clinical examination and radiographic findings need to be conclusive. Expectations need to be realistic and reasonable. When all of these criteria are met, the attending physician may indicate an operation. Finally, the patients' level of suffering and discomfort defines the timing of an arthroplasty.
- 1 December 2020
- Published by Hogrefe Publishing Group in Therapeutische Umschau
- Vol. 77 (10) , 469-474
When should we perform a knee or hip arthroplasty?
Total hip (THA) and knee arthroptasties (TKA) rank among the most successful and effective orthopedic operations. They improve health-related quality of life and result in high patient satisfaction. But when is the right moment to perform an arthroplasty? A differentiated indication is decisive for a good outcome. Pain, limitations in quality of life because of osteoarthritis, radiological confirmation of osteoarthritis and inadequate response to conservative treatment should be reported. Moreover, medical history, clinical examination and radiographic findings need to be conclusive. Expectations need to be realistic and reasonable. When all of these criteria are met, the attending physician may indicate an operation. Finally, the patients' level of suffering and discomfort defines the timing of an arthroplasty.
- 12 March 2020
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 29 (2) , 483-490
Osteoarthritic knees have a highly variable patellofemoral alignment: a systematic review
Purpose: This systematic review aimed to evaluate the variability of patellofemoral (PF) alignment and trochlear morphology in osteoarthritic knees.Methods: PF alignment of the knee was defined by the following parameters: the sulcus angle (SA), femoral trochlear depth (FTD), patellar tilt angle (PTA), lateral patellofemoral angle (LPFA), lateral femoral trochlear inclination (LFTI) and tibial tubercle–trochlear groove distance (TT–TG). The electronic databases MEDLINE and EMBASE were searched from database inception to the search date (February 19, 2019) and were screened for relevant studies. The PRISMA guidelines were followed. Articles reporting PF alignment measurements of osteoarthritic knees in patients over 40 years old were included. Data were extracted and methodological quality was assessed using a 14‐item checklist.Results: A total of 8 studies met the inclusion criteria. The studies reported mean values ± SD between 120° and 141.1° ± 7.7 for the SA; 5.8 mm ± 1.4 for the FTD; between − 0.1° ± 3.3 and 10.3° ± 5.7 for the PTA; between 5.8° ± 5.4 and 17° for the LPFA; between 23.2° ± 5.0 and 27.1° ± 4.4 for the LFTI; and 5.8 mm ± 5.4 for the TT‐TG.Conclusion: PF alignment in the osteoarthritic knee is more variable than expected. This finding should encourage surgeons to consider the individual preoperative PF alignment more precisely with the aim of reducing anterior knee pain (AKP) after TKA. 3D‐CT imaging might be of great value to analyse the PF alignment in an appropriate way.Level of evidence: Level III.
- 12 March 2020
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 29 (2) , 483-490
Osteoarthritic knees have a highly variable patellofemoral alignment: a systematic review
Purpose: This systematic review aimed to evaluate the variability of patellofemoral (PF) alignment and trochlear morphology in osteoarthritic knees.Methods: PF alignment of the knee was defined by the following parameters: the sulcus angle (SA), femoral trochlear depth (FTD), patellar tilt angle (PTA), lateral patellofemoral angle (LPFA), lateral femoral trochlear inclination (LFTI) and tibial tubercle–trochlear groove distance (TT–TG). The electronic databases MEDLINE and EMBASE were searched from database inception to the search date (February 19, 2019) and were screened for relevant studies. The PRISMA guidelines were followed. Articles reporting PF alignment measurements of osteoarthritic knees in patients over 40 years old were included. Data were extracted and methodological quality was assessed using a 14‐item checklist.Results: A total of 8 studies met the inclusion criteria. The studies reported mean values ± SD between 120° and 141.1° ± 7.7 for the SA; 5.8 mm ± 1.4 for the FTD; between − 0.1° ± 3.3 and 10.3° ± 5.7 for the PTA; between 5.8° ± 5.4 and 17° for the LPFA; between 23.2° ± 5.0 and 27.1° ± 4.4 for the LFTI; and 5.8 mm ± 5.4 for the TT‐TG.Conclusion: PF alignment in the osteoarthritic knee is more variable than expected. This finding should encourage surgeons to consider the individual preoperative PF alignment more precisely with the aim of reducing anterior knee pain (AKP) after TKA. 3D‐CT imaging might be of great value to analyse the PF alignment in an appropriate way.Level of evidence: Level III.
- 15 February 2020
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 28 (12) , 3962-3968
No difference in radiolucent lines after TKA: a matched‐pair analysis of the classic implant and its evolutional design
Purpose: Total knee arthroplasty (TKA) designs evolve continuously to improve patient outcomes. However, incidences of radiolucent lines (RLL) in the latest TKA system have recently been reported, raising concerns. The purpose of the current study was to compare radiographic outcomes of this new TKA implant to its predecessor design.Methods: A group of 100 patients undergoing TKA using the newer design (Attune) was matched by age and gender to 191 patients with the classic design (LCS). All patients underwent computer‐navigated primary TKA by the same surgeon using the same technique. Radiographs were taken before discharge, and 2 and 12 months postoperatively. Radiographic analysis was performed independently by three assessors, using the Modern Knee Society Radiographic Evaluation System and Methodology (MKSRES).Results: At 12 months postoperatively, the incidence of RLL did not statistically differ between the two implants (14%, n = 14 Attune vs. 8% n = 17 LCS, n.s.). The posterior femoral flange was most commonly affected (12%; n = 12 Attune vs. 7.9%; n = 15 LCS, n.s.) followed by the anterior flange (1%; n = 1 Attune vs. 3.1%; n = 6 LCS, n.s.). The tibial baseplate was only affected in 1% (n = 1) of the Attune and 2.6% (n = 5) of the LCS (n.s.).Conclusion: At 12 months follow‐up we found no significant difference in RLL between the two implants. Both Attune and LCS TKA systems showed RLL predominantly at the posterior femoral flange. The reasons for the RLL remain a matter of speculation; however, shortcomings in surgical and cementing techniques seem to be more important than implant‐related factors.Level of evidence: III
- 15 February 2020
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 28 (12) , 3962-3968
No difference in radiolucent lines after TKA: a matched‐pair analysis of the classic implant and its evolutional design
Purpose: Total knee arthroplasty (TKA) designs evolve continuously to improve patient outcomes. However, incidences of radiolucent lines (RLL) in the latest TKA system have recently been reported, raising concerns. The purpose of the current study was to compare radiographic outcomes of this new TKA implant to its predecessor design.Methods: A group of 100 patients undergoing TKA using the newer design (Attune) was matched by age and gender to 191 patients with the classic design (LCS). All patients underwent computer‐navigated primary TKA by the same surgeon using the same technique. Radiographs were taken before discharge, and 2 and 12 months postoperatively. Radiographic analysis was performed independently by three assessors, using the Modern Knee Society Radiographic Evaluation System and Methodology (MKSRES).Results: At 12 months postoperatively, the incidence of RLL did not statistically differ between the two implants (14%, n = 14 Attune vs. 8% n = 17 LCS, n.s.). The posterior femoral flange was most commonly affected (12%; n = 12 Attune vs. 7.9%; n = 15 LCS, n.s.) followed by the anterior flange (1%; n = 1 Attune vs. 3.1%; n = 6 LCS, n.s.). The tibial baseplate was only affected in 1% (n = 1) of the Attune and 2.6% (n = 5) of the LCS (n.s.).Conclusion: At 12 months follow‐up we found no significant difference in RLL between the two implants. Both Attune and LCS TKA systems showed RLL predominantly at the posterior femoral flange. The reasons for the RLL remain a matter of speculation; however, shortcomings in surgical and cementing techniques seem to be more important than implant‐related factors.Level of evidence: III
- 13 September 2019
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 28 (2) , 407
Correction to: Healthy knees have a highly variable patellofemoral alignment: a systematic review
Authors would like to add the below acknowledgement statement to the original article.
- 13 September 2019
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 28 (2) , 407
Correction to: Healthy knees have a highly variable patellofemoral alignment: a systematic review
Authors would like to add the below acknowledgement statement to the original article.
- 29 June 2019
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 28 (2) , 398-406
Healthy knees have a highly variable patellofemoral alignment: a systematic review
There is still lack of knowledge regarding the variability of patellofemoral alignment in healthy, non-osteoarthritic knees, without patellofemoral instability. Therefore, a systematic review of the existing literature was performed to evaluate the variability of patellofemoral alignment.
- 29 June 2019
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 28 (2) , 398-406
Healthy knees have a highly variable patellofemoral alignment: a systematic review
There is still lack of knowledge regarding the variability of patellofemoral alignment in healthy, non-osteoarthritic knees, without patellofemoral instability. Therefore, a systematic review of the existing literature was performed to evaluate the variability of patellofemoral alignment.
- 14 February 2019
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 27 (7) , 2124-2129
No difference in joint awareness after TKA: a matched-pair analysis of a classic implant and its evolutional design
Total knee arthroplasty (TKA) designs continuously evolve with the aim of improving patient outcomes. The purpose of the current study was to compare clinical and patient-reported outcome (PRO) results of a new TKA implant to its predecessor. The hypothesis of this study was that joint awareness and range of motion (ROM) of the newer design would be better than the classic design.
- 14 February 2019
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 27 (7) , 2124-2129
No difference in joint awareness after TKA: a matched-pair analysis of a classic implant and its evolutional design
Total knee arthroplasty (TKA) designs continuously evolve with the aim of improving patient outcomes. The purpose of the current study was to compare clinical and patient-reported outcome (PRO) results of a new TKA implant to its predecessor. The hypothesis of this study was that joint awareness and range of motion (ROM) of the newer design would be better than the classic design.
- 22 October 2018
- Published by Springer Nature in Acta Physiologiae Plantarum
- Vol. 40 (11) , 193
11th International Conference PLANT FUNCTIONING UNDER ENVIRONMENTAL STRESS September 12–15, 2018, Cracow, Poland
- 22 October 2018
- Published by Springer Nature in Acta Physiologiae Plantarum
- Vol. 40 (11) , 193
11th International Conference PLANT FUNCTIONING UNDER ENVIRONMENTAL STRESS September 12–15, 2018, Cracow, Poland
- 21 September 2018
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 27 (5) , 1403-1409
Highly variable tibial tubercle–trochlear groove distance (TT–TG) in osteoarthritic knees should be considered when performing TKA
Purpose: The tibial tubercle–trochlear groove distance (TT–TG) is an established measurement to assist diagnosis and treatment of patellofemoral instability. However, little is known about the distribution of TT–TG in osteoarthritic knees. The purpose of the current study is to investigate the TT–TG in a large cohort of osteoarthritic knees and to analyse, in particular, the association of knee alignment and TT–TG.Methods: Data from 962 consecutive patients [455 male, 507 female; mean age ± SD 70.8 ± 9.3 (37–96)] who had undergone 3D‐CT and preoperative knee planning with validated commercial 3D planning software before total knee arthroplasty (TKA) were collected prospectively. The TT–TG, coronal hip knee ankle angle (HKA), femoral anteversion (AVF), external tibial torsion (ETT), and femorotibial rotation (Rot FT) were analysed. Pearson correlations were performed to assess correlations between TT–TG, mechanical axis, and rotational parameters (p < 0.05).Results: HKA showed a strong correlation with TT–TG (r = 0.488; p < 0.001) with 98 (67.1%) and 45 (30.8%) of valgus knees having respective abnormal and pathological TT–TG values. There were no significant correlations between parameters of rotational alignment (AVF, ETT, Rot FT) and TT–TG. Mean TT–TG was 12.9 ± 5.6 mm, ranging from 0.0 to 33.7 mm. 325 (33.8%) of all patients had abnormal (> 15 mm) and 101 (10.5%) had pathological (> 20 mm) values. A varus alignment was present in 716 (74.4%) of the cases (HKA < − 1.5°), a neutral alignment in 100 (10.4%), and a valgus alignment in 146 (15.2%) (HKA > 1.5°).Conclusion: A wide variation of TT–TG values in osteoarthritic knees was shown by our results. There was a relevant influence of coronal limb alignment on the TT–TG—the more valgus the higher and more pathological the TT–TG. With the aim of having a more personalised TKA, the individual TT–TG should be taken into account to improve the outcome.Level of clinical evidence: III. Retrospective cohort study.
- 21 September 2018
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 27 (5) , 1403-1409
Highly variable tibial tubercle–trochlear groove distance (TT–TG) in osteoarthritic knees should be considered when performing TKA
Purpose: The tibial tubercle–trochlear groove distance (TT–TG) is an established measurement to assist diagnosis and treatment of patellofemoral instability. However, little is known about the distribution of TT–TG in osteoarthritic knees. The purpose of the current study is to investigate the TT–TG in a large cohort of osteoarthritic knees and to analyse, in particular, the association of knee alignment and TT–TG.Methods: Data from 962 consecutive patients [455 male, 507 female; mean age ± SD 70.8 ± 9.3 (37–96)] who had undergone 3D‐CT and preoperative knee planning with validated commercial 3D planning software before total knee arthroplasty (TKA) were collected prospectively. The TT–TG, coronal hip knee ankle angle (HKA), femoral anteversion (AVF), external tibial torsion (ETT), and femorotibial rotation (Rot FT) were analysed. Pearson correlations were performed to assess correlations between TT–TG, mechanical axis, and rotational parameters (p < 0.05).Results: HKA showed a strong correlation with TT–TG (r = 0.488; p < 0.001) with 98 (67.1%) and 45 (30.8%) of valgus knees having respective abnormal and pathological TT–TG values. There were no significant correlations between parameters of rotational alignment (AVF, ETT, Rot FT) and TT–TG. Mean TT–TG was 12.9 ± 5.6 mm, ranging from 0.0 to 33.7 mm. 325 (33.8%) of all patients had abnormal (> 15 mm) and 101 (10.5%) had pathological (> 20 mm) values. A varus alignment was present in 716 (74.4%) of the cases (HKA < − 1.5°), a neutral alignment in 100 (10.4%), and a valgus alignment in 146 (15.2%) (HKA > 1.5°).Conclusion: A wide variation of TT–TG values in osteoarthritic knees was shown by our results. There was a relevant influence of coronal limb alignment on the TT–TG—the more valgus the higher and more pathological the TT–TG. With the aim of having a more personalised TKA, the individual TT–TG should be taken into account to improve the outcome.Level of clinical evidence: III. Retrospective cohort study.