Yohei Kawakami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yohei Kawakami has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Ryosuke Kuroda
Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
3 shared publications - Masahiro Kurosaka
Kobe University Graduate School of Medicine
2 shared publications - Takehiko Matsushita
Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan
2 shared publications - Tomoyuki Matsumoto
Department of Orthopaedic Surgery Kobe University Graduate School of Medicine Kobe Japan
2 shared publications - Freddie H. Fu
Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
1 shared publication Harunobu Uemoto
<!--1--> Department of Orthopedic Surgery, Joint Surgery Centre Takatsuki General Hospital 1‐3‐13 Kosobe‐cho 569‐1192 Takatsuki Osaka Japan
1 shared publication
Latest Publications
- Open Access
- 1 March 2020
- Published by Elsevier in Biomaterials
- Vol. 235, 119781
Reduced nucleotomy-induced intervertebral disc disruption through spontaneous spheroid formation by the Low Adhesive Scaffold Collagen (LASCol)
- 1 March 2020
- Published by Elsevier in Biomaterials
- Vol. 235, 119781
Open AccessReduced nucleotomy-induced intervertebral disc disruption through spontaneous spheroid formation by the Low Adhesive Scaffold Collagen (LASCol)
- 1 February 2015
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 23 (2) , 217-223
A radiographic analysis of alignment of the lower extremities – initiation and progression of varus-type knee osteoarthritis
- 1 February 2015
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 23 (2) , 217-223
A radiographic analysis of alignment of the lower extremities – initiation and progression of varus-type knee osteoarthritis
- Open Access
- 17 November 2014
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 16 (6) , 1-10
Local intra-articular injection of rapamycin delays articular cartilage degeneration in a murine model of osteoarthritis
Introduction: Recent studies have revealed that rapamycin activates autophagy in human chondrocytes preventing the development of osteoarthritis (OA) like changes in vitro, while the systemic injection of rapamycin reduces the severity of experimental osteoarthritis in a murine model of OA in vivo. Since the systemic use of rapamycin is associated with numerous side effects, the goal of the current study was to examine the beneficial effect of local intra-articular injection of rapamycin in a murine model of OA and to elucidate the mechanism of action of rapamycin on articular cartilage. Methods: Destabilization of the medial meniscus (DMM) was performed on 10-week-old male mice to induce OA. Intra-articular injections of 10 μl of rapamycin (10 μM) were administered twice weekly for 8 weeks. Articular cartilage damage was analyzed by histology using a semi-quantitative scoring system at 8 and 12 weeks after surgery. Mammalian target of rapamycin (mTOR), light chain 3 (LC3), vascular endothelial growth factor (VEGF), collagen, type X alpha 1 (COL10A1), and matrix metallopeptidase 13 (MMP13) expressions were analyzed by immunohistochemistry. VEGF, COL10A1, and MMP13 expressions were further examined via quantitative RT-PCR (qPCR). Results: Intra-articular injection of rapamycin significantly reduced the severity of articular cartilage degradation at 8 and 12 weeks after DMM surgery. A reduction in mTOR expression and the activation of LC3 (an autophagy marker) in the chondrocytes was observed in the rapamycin treated mice. Rapamycin treatment also reduced VEGF, COL10A1, and MMP13 expressions at 8 and 12 weeks after DMM surgery. Conclusion: These results demonstrate that the intra-articular injection of rapamycin could reduce mTOR expression, leading to a delay in articular cartilage degradation in our OA murine model. Our observations suggest that local intra-articular injection of rapamycin could represent a potential therapeutic approach to prevent OA.
- 17 November 2014
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 16 (6) , 1-10
Open AccessLocal intra-articular injection of rapamycin delays articular cartilage degeneration in a murine model of osteoarthritis
Introduction: Recent studies have revealed that rapamycin activates autophagy in human chondrocytes preventing the development of osteoarthritis (OA) like changes in vitro, while the systemic injection of rapamycin reduces the severity of experimental osteoarthritis in a murine model of OA in vivo. Since the systemic use of rapamycin is associated with numerous side effects, the goal of the current study was to examine the beneficial effect of local intra-articular injection of rapamycin in a murine model of OA and to elucidate the mechanism of action of rapamycin on articular cartilage. Methods: Destabilization of the medial meniscus (DMM) was performed on 10-week-old male mice to induce OA. Intra-articular injections of 10 μl of rapamycin (10 μM) were administered twice weekly for 8 weeks. Articular cartilage damage was analyzed by histology using a semi-quantitative scoring system at 8 and 12 weeks after surgery. Mammalian target of rapamycin (mTOR), light chain 3 (LC3), vascular endothelial growth factor (VEGF), collagen, type X alpha 1 (COL10A1), and matrix metallopeptidase 13 (MMP13) expressions were analyzed by immunohistochemistry. VEGF, COL10A1, and MMP13 expressions were further examined via quantitative RT-PCR (qPCR). Results: Intra-articular injection of rapamycin significantly reduced the severity of articular cartilage degradation at 8 and 12 weeks after DMM surgery. A reduction in mTOR expression and the activation of LC3 (an autophagy marker) in the chondrocytes was observed in the rapamycin treated mice. Rapamycin treatment also reduced VEGF, COL10A1, and MMP13 expressions at 8 and 12 weeks after DMM surgery. Conclusion: These results demonstrate that the intra-articular injection of rapamycin could reduce mTOR expression, leading to a delay in articular cartilage degradation in our OA murine model. Our observations suggest that local intra-articular injection of rapamycin could represent a potential therapeutic approach to prevent OA.
- 22 October 2011
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 20 (8) , 1503-1510
The accuracy of bone tunnel position using fluoroscopic‐based navigation system in anterior cruciate ligament reconstruction
Purpose: The first purpose of this study was to examine whether fluoroscopic‐based navigation system contributes to the accuracy and reproducibility of the bone tunnel placements in single‐bundle anterior cruciate ligament (ACL) reconstruction. The second purpose was to investigate the application of the navigation system for double‐bundle ACL reconstruction.Methods: A hospital‐based case–control study was conducted, including a consecutive series of 55 patients. In 37 patients who received single‐bundle ACL reconstruction, surgeries were performed with this system for 19 knees (group 1) and without this system for 18 knees (group 2). The positioning of the femoral and tibial tunnels was evaluated by plain sagittal radiographs. In 18 patients who received double‐bundle ACL reconstruction using the navigation system (group 3), the bone tunnel positions were assessed by three‐dimensional computed tomography (3D‐CT). Clinical assessment of all patients was followed with the use of Lysholm Knees Score and IKDC.Results: Taking 0% as the anterior and 100% as the posterior extent, the femoral tunnels were 74.9 ± 3.0% in group 1 and 71.5 ± 5.8% in group 2 along Blumensaat’s line, and the tibial tunnels were 42.3 ± 1.4% in group 1 and 42.5 ± 4.6% in group 2 along the tibia plateau. The bone tunnel positions in group 1 were located significantly closer to the position planned preoperatively and varied less in both femur and tibial side, compared with those without navigation (group 2). (Femur: P < 0.05, Tibia: P < 0.001) 3D‐CT evaluation of double‐bundle ACL reconstruction (group 3) also demonstrated that the bone tunnel positions of both anteromedial (AM) and posterolateral (PL) were placed as we expected.Conclusion: The fluoroscopic‐based navigation system contributed to the more reproducible placement of the bone tunnel during single‐bundle ACL reconstruction compared with conventional technique. Additionally, this device was also useful for double‐bundle ACL reconstruction.Level of evidence: Case–control study, Therapeutic study, Level III.
- 22 October 2011
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 20 (8) , 1503-1510
The accuracy of bone tunnel position using fluoroscopic‐based navigation system in anterior cruciate ligament reconstruction
Purpose: The first purpose of this study was to examine whether fluoroscopic‐based navigation system contributes to the accuracy and reproducibility of the bone tunnel placements in single‐bundle anterior cruciate ligament (ACL) reconstruction. The second purpose was to investigate the application of the navigation system for double‐bundle ACL reconstruction.Methods: A hospital‐based case–control study was conducted, including a consecutive series of 55 patients. In 37 patients who received single‐bundle ACL reconstruction, surgeries were performed with this system for 19 knees (group 1) and without this system for 18 knees (group 2). The positioning of the femoral and tibial tunnels was evaluated by plain sagittal radiographs. In 18 patients who received double‐bundle ACL reconstruction using the navigation system (group 3), the bone tunnel positions were assessed by three‐dimensional computed tomography (3D‐CT). Clinical assessment of all patients was followed with the use of Lysholm Knees Score and IKDC.Results: Taking 0% as the anterior and 100% as the posterior extent, the femoral tunnels were 74.9 ± 3.0% in group 1 and 71.5 ± 5.8% in group 2 along Blumensaat’s line, and the tibial tunnels were 42.3 ± 1.4% in group 1 and 42.5 ± 4.6% in group 2 along the tibia plateau. The bone tunnel positions in group 1 were located significantly closer to the position planned preoperatively and varied less in both femur and tibial side, compared with those without navigation (group 2). (Femur: P < 0.05, Tibia: P < 0.001) 3D‐CT evaluation of double‐bundle ACL reconstruction (group 3) also demonstrated that the bone tunnel positions of both anteromedial (AM) and posterolateral (PL) were placed as we expected.Conclusion: The fluoroscopic‐based navigation system contributed to the more reproducible placement of the bone tunnel during single‐bundle ACL reconstruction compared with conventional technique. Additionally, this device was also useful for double‐bundle ACL reconstruction.Level of evidence: Case–control study, Therapeutic study, Level III.