Markus D. Enderle
Research Interests
Markus D. Enderle has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Ansgar Hieronymus
2 shared publications- Mara N.I. Szyrach
Erbe Elektromedizin GmbH, Tuebingen, Germany
2 shared publications Georg F. Kaehler
1 shared publication- Georg Kähler
Universität Heidelberg
1 shared publication - Georg Nilius
HELIOS Klinik Hagen-Ambrock
1 shared publication - Juergen Hetzel
Department of Medical Oncology and Pneumology, Eberhard Karls University, 72076 Tübingen, Germany
1 shared publication
Latest Publications
- 31 August 2009
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 70 (2) , 362-368
Investigation of the thermal tissue effects of the argon plasma coagulation modes “pulsed” and “precise” on the porcine esophagus, ex vivo and in vivo
- 31 August 2009
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 70 (2) , 362-368
Investigation of the thermal tissue effects of the argon plasma coagulation modes “pulsed” and “precise” on the porcine esophagus, ex vivo and in vivo
- 23 June 2009
- Published by Springer Nature in Lung
- Vol. 187 (4) , 253-259
Experimental Study on Biopsy Sampling Using New Flexible Cryoprobes: Influence of Activation Time, Probe Size, Tissue Consistency, and Contact Pressure of the Probe on the Size of the Biopsy Specimen
Cryoextraction is a procedure for recanalization of obstructed airways caused by exophytic growing tumors. Biopsy samples obtained with this method can be used for histological diagnosis. The objective of this study was to evaluate the parameters influencing the size of cryobiopsies in an in vitro animal model. New flexible cryoprobes with different diameters were used to extract biopsies from lung tissue. These biopsies were compared with forceps biopsy (gold standard) in terms of the biopsy size. Tissue dependency of the biopsy size was analyzed by comparing biopsies taken from the lung, the liver, and gastric mucosa. The effect of contact pressure exerted by the tip of the cryoprobe on the tissue was analyzed on liver tissue separately. Biopsy size was estimated by measuring the weight and the diameter. Weight and diameter of cryobiopsies correlated positively with longer activation times and larger diameters of the cryoprobe. The weight of the biopsies was tissue dependent: lung < liver < stomach. Only little tissue dependency was found for the biopsy diameter. The biopsy size increased when the probe was pressed on the tissue during cooling. Cryobiopsies can be taken from different tissue types with flexible cryoprobes. The size of the samples depends on tissue type, probe diameter, application time, and pressure exerted by the probe on the tissue. Even the cryoprobe with the smallest diameter can provide larger biopsies than a forceps biopsy in lung. It can be expected that the same parameters influence the sample size of biopsies in vivo.
- 23 June 2009
- Published by Springer Nature in Lung
- Vol. 187 (4) , 253-259
Experimental Study on Biopsy Sampling Using New Flexible Cryoprobes: Influence of Activation Time, Probe Size, Tissue Consistency, and Contact Pressure of the Probe on the Size of the Biopsy Specimen
Cryoextraction is a procedure for recanalization of obstructed airways caused by exophytic growing tumors. Biopsy samples obtained with this method can be used for histological diagnosis. The objective of this study was to evaluate the parameters influencing the size of cryobiopsies in an in vitro animal model. New flexible cryoprobes with different diameters were used to extract biopsies from lung tissue. These biopsies were compared with forceps biopsy (gold standard) in terms of the biopsy size. Tissue dependency of the biopsy size was analyzed by comparing biopsies taken from the lung, the liver, and gastric mucosa. The effect of contact pressure exerted by the tip of the cryoprobe on the tissue was analyzed on liver tissue separately. Biopsy size was estimated by measuring the weight and the diameter. Weight and diameter of cryobiopsies correlated positively with longer activation times and larger diameters of the cryoprobe. The weight of the biopsies was tissue dependent: lung < liver < stomach. Only little tissue dependency was found for the biopsy diameter. The biopsy size increased when the probe was pressed on the tissue during cooling. Cryobiopsies can be taken from different tissue types with flexible cryoprobes. The size of the samples depends on tissue type, probe diameter, application time, and pressure exerted by the probe on the tissue. Even the cryoprobe with the smallest diameter can provide larger biopsies than a forceps biopsy in lung. It can be expected that the same parameters influence the sample size of biopsies in vivo.
- 30 April 2008
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 67 (5) , AB145-AB146
Investigation of the Thermal Tissue Effects of the APC Modes PULSED and PRECISE On Porcine Esophagus Ex Vivo and In Vivo
- 30 April 2008
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 67 (5) , AB145-AB146
Investigation of the Thermal Tissue Effects of the APC Modes PULSED and PRECISE On Porcine Esophagus Ex Vivo and In Vivo