MWMordechai Weiss

Mordechai Weiss

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mordechai Weiss has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Discordant effect of body mass index on bone mineral density and speed of sound

    by Miriam Steinschneider, Philippe Hagag, Micha J Rapoport, Mordechai Weiss

    Increased BMI may affect the determination of bone mineral density (BMD) by dual X-ray absorptiometry (DXA) and speed of sound (SOS) measured across bones. Preliminary data suggest that axial SOS is less affected by soft tissue. The purpose of this study is to evaluate the effect of body mass index (BMI) on BMD and SOS measured along bones. We compared axial BMD determined by DXA with SOS along the phalanx, radius and tibia in 22 overweight (BMI > 27 kg/m2), and 11 lean (BMI = 21 kg/m2) postmenopausal women. Serum bone specific alkaline phosphatase and urinary deoxypyridinoline excretion determined bone turnover. Mean femoral neck--but not lumbar spine BMD was higher in the overweight--as compared with the lean group (0.70 +/- 0.82, -0.99 +/- 0.52, P < 0.00001). Femoral neck BMD in the overweight--but not in the lean group highly correlated with BMI (R = 0.68. P < 0.0001). Mean SOS at all measurement sites was similar in both groups and did not correlate with BMI. Bone turnover was similar in the two study groups. The high BMI of postmenopausal women may result in spuriously high BMD. SOS measured along bones may be a more appropriate means for evaluating bones of overweight women.


  • Reference Database for Bone Speed of Sound Measurement by a Novel Quantitative Multi-site Ultrasound Device

    by M. Weiss, A. B. Ben-Shlomo, P. Hagag, M. Rapoport

    The nonuniform skeletal involvement in osteoporosis argues for multi-site evaluation. The Sunlight Omnisense (Sunlight Ultrasound Technologies, Israel) is a multi-site device that measures speed of sound (SOS) at the appendicular skeleton. We report the reference database for SOS at the radius (RAD), tibia (TIB), metatarsus (MTR) and phalanx (PLX). The database was obtained from 1521 healthy Israeli women (age 20–90 years) out of 2051 respondents. SOS was determined in 97.6% of the participants at the PLX, 96.4% at the TIB, 93.6% at the RAD and 85.1% at the MTR; it was not measurable in 0.5%. Short-term coefficient of variation was lowest at the RAD and always less than 1%. Maximal SOS was noted at 35–45 years of age in three of the sites (RAD 4169 m/s, MTR 3663 m/s, PLX 4047 m/s, respectively) but 10 years earlier at the TIB (3939 m/s). In the perimenopausal period (age 46–55 years), SOS was always lower in post- as compared with premenopausal women (pT-score at the RAD and PLX was <−2.5. This is similar to that of dual-energy X-ray absorptiometry (DXA)-determined spine bone mineral density (BMD) and somewhat lower than hip BMD. Equivalent T-score curves obtained by percentile adjustment of SOS at various sites to that of the RAD (at age group 60–69 years) reveal convergence and indicate that 52–68% of women older than 79 years are osteoporotic. In conclusion, multi-site peripheral SOS measurements reveal age-dependent bone changes with a high degree of measurement precision and indicate a prevalence of osteoporosis similar to that obtained by DXA.


  • Effect of estrogen replacement therapy on speed of sound at multiple skeletal sites

    by M Weiss, A Ben Shlomo, P Hagag, M Rapoport, S Ish-Shalom