Ahmad Fayez Bakr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ahmad Fayez Bakr has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Ahmad El-Altar
From the Departments of Neonatology and Anesthesia Faculty of Medicine, University of Alexandria, Egypt
1 shared publicationAhmad El-Attar
1 shared publication- Gale Sarette
Dharan Health Centre
1 shared publication H.S. Habib
Department of Pediatrics, King Abdulaziz University–Jeddah, Jeddah, Saudi Arabia
1 shared publicationHamed S. Habib
King Abdel-Aziz Specialist Hospital Taif Saudi Arabia
1 shared publication- Mohammad M Abbas
Departments of Obstetrics, King Abdul-Aziz Specialist Hospital, Taif, Saudi Arabia
1 shared publication
Latest Publications
- 7 March 2006
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 165 (7) , 442-445
Measurement of reticulocyte hemoglobin content to diagnose iron deficiency in Saudi children
Iron deficiency and iron deficiency anemia are common conditions in children, especially in developing countries. It is often difficult for the pediatrician to know which indices should be used in the diagnosis of these conditions in children. Reticulocyte hemoglobin (Hb) content (CHr) has been shown to be an accurate indicator of anemia, however whether its use suits the situation in developing countries or not is unclear. The aim of this study was to evaluate the value and effectiveness of using CHr as a method to diagnose iron deficiency and iron deficiency anemia in Saudi children. The samples for the study were collected from 305 children suspected to have anemia. Complete blood count, transferrin saturation (Tfsat), ferritin, circulating transferrin receptor (TfR) and CHr were measured. Three groups were defined, iron deficiency (Tfsat 11 g/dL; n=120), iron deficiency anemia (Tfsat n=112). The anemic group had significantly lower macrocytic anemia (MCV), mean corpuscular hemoglobin (MCH) and CHr. All of the variables in the anemia group were significantly lower than those of the control group except for the ferritin level. Compared to the control group, the iron deficiency group also showed significantly lower values except for transferrin receptor and the ferritin levels. CHr levels of <26 pg correlated well with anemic states. CHr together with a complete blood count may provide an alternative to the traditional hematologic or biochemical panel for the diagnosis of iron deficiency and iron deficiency anemia in young children and is cost-effective in developing countries. A CHr cut-off level of 26 pg is considered to be a reasonable indicator of anemic states.
- 7 March 2006
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 165 (7) , 442-445
Measurement of reticulocyte hemoglobin content to diagnose iron deficiency in Saudi children
Iron deficiency and iron deficiency anemia are common conditions in children, especially in developing countries. It is often difficult for the pediatrician to know which indices should be used in the diagnosis of these conditions in children. Reticulocyte hemoglobin (Hb) content (CHr) has been shown to be an accurate indicator of anemia, however whether its use suits the situation in developing countries or not is unclear. The aim of this study was to evaluate the value and effectiveness of using CHr as a method to diagnose iron deficiency and iron deficiency anemia in Saudi children. The samples for the study were collected from 305 children suspected to have anemia. Complete blood count, transferrin saturation (Tfsat), ferritin, circulating transferrin receptor (TfR) and CHr were measured. Three groups were defined, iron deficiency (Tfsat 11 g/dL; n=120), iron deficiency anemia (Tfsat n=112). The anemic group had significantly lower macrocytic anemia (MCV), mean corpuscular hemoglobin (MCH) and CHr. All of the variables in the anemia group were significantly lower than those of the control group except for the ferritin level. Compared to the control group, the iron deficiency group also showed significantly lower values except for transferrin receptor and the ferritin levels. CHr levels of <26 pg correlated well with anemic states. CHr together with a complete blood count may provide an alternative to the traditional hematologic or biochemical panel for the diagnosis of iron deficiency and iron deficiency anemia in young children and is cost-effective in developing countries. A CHr cut-off level of 26 pg is considered to be a reasonable indicator of anemic states.
- Open Access
- 16 February 2006
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 6 (1) , 3
What is the optimal gestational age for twin delivery
Background: The question about outcome in twins delivered early versus late remains unanswered. The objective of this study was to evaluate the association of the timing of delivering twins and the perinatal outcome. Methods: A prospective cohort study was carried-out in Alexandria University Maternity Hospital. We planned to examine the records of twin deliveries over 2 years. The inclusion criteria were twin deliveries with gestational age at delivery at least 36 completed weeks. Twins of mothers with chronic illness and those with congenital anomalies were excluded. Perinatal outcome parameters (morbidity and mortality) were defined and evaluated. Results: Out of 273 twin sets, 197 (72.2%) met the inclusion criteria. They were classified into 3 groups according to the gestational age at delivery. Neonatal morbidity and maternal complications were higher in those delivered earlier. Twins electively delivered had worse outcome than those delivered spontaneously. In the elective group, there was no difference in the outcome between those delivered earlier or later. Conclusion: Twins, when the pregnancy is uncomplicated, continue to grow and mature with advancement of the gestational age. In the absence of significant maternal complications, it is advisable to deliver twins only at 38 completed weeks' gestation or later to avoid neonatal complications.
- 16 February 2006
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 6 (1) , 3
Open AccessWhat is the optimal gestational age for twin delivery
Background: The question about outcome in twins delivered early versus late remains unanswered. The objective of this study was to evaluate the association of the timing of delivering twins and the perinatal outcome. Methods: A prospective cohort study was carried-out in Alexandria University Maternity Hospital. We planned to examine the records of twin deliveries over 2 years. The inclusion criteria were twin deliveries with gestational age at delivery at least 36 completed weeks. Twins of mothers with chronic illness and those with congenital anomalies were excluded. Perinatal outcome parameters (morbidity and mortality) were defined and evaluated. Results: Out of 273 twin sets, 197 (72.2%) met the inclusion criteria. They were classified into 3 groups according to the gestational age at delivery. Neonatal morbidity and maternal complications were higher in those delivered earlier. Twins electively delivered had worse outcome than those delivered spontaneously. In the elective group, there was no difference in the outcome between those delivered earlier or later. Conclusion: Twins, when the pregnancy is uncomplicated, continue to grow and mature with advancement of the gestational age. In the absence of significant maternal complications, it is advisable to deliver twins only at 38 completed weeks' gestation or later to avoid neonatal complications.
- Open Access
- 16 February 2006
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 6 (1)
Severe respiratory distress in term infants born electively at high altitude
Background We studied the contribution of elective delivery to severe respiratory distress syndrome (RDS) in term babies born at high altitude. Methods We prospectively studied the charts of term babies born in Taif Maternity Hospital (1640 m above sea level) between 1/1/2004 and 31/10/2004 who developed RDS and required mechanical ventilation. Results 8634 deliveries occurred from 37–<41 weeks; 13 (0.15%) had RDS requiring mechanical ventilation. Seven infants delivered at 37–<38 weeks, (OR for RDS = 26 95%CI -4.6 to 5.8), five delivered at 38–39 weeks. Six of 13 infants were electively delivered without documented lung maturity. Conclusion Infants born at 37 and 38 weeks' gestation remain at significantly increased risk for severe RDS. Elective delivery is responsible for 50% of the potentially avoidable cases. Our data suggest that the altitude does not seem to influence the incidence of severe RDS in term infants born electively.
- 16 February 2006
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 6 (1)
Open AccessSevere respiratory distress in term infants born electively at high altitude
Background We studied the contribution of elective delivery to severe respiratory distress syndrome (RDS) in term babies born at high altitude. Methods We prospectively studied the charts of term babies born in Taif Maternity Hospital (1640 m above sea level) between 1/1/2004 and 31/10/2004 who developed RDS and required mechanical ventilation. Results 8634 deliveries occurred from 37–<41 weeks; 13 (0.15%) had RDS requiring mechanical ventilation. Seven infants delivered at 37–<38 weeks, (OR for RDS = 26 95%CI -4.6 to 5.8), five delivered at 38–39 weeks. Six of 13 infants were electively delivered without documented lung maturity. Conclusion Infants born at 37 and 38 weeks' gestation remain at significantly increased risk for severe RDS. Elective delivery is responsible for 50% of the potentially avoidable cases. Our data suggest that the altitude does not seem to influence the incidence of severe RDS in term infants born electively.
- Open Access
- 24 October 2005
- Published by Oxford University Press (OUP) in Journal of Tropical Pediatrics
- Vol. 52 (5) , 382
The Rear or the Front in Bag and Mask Oxygenation of the Neonates
Different methods and different self-inflating bag and mask sets (SIBMS) are used for passive oxygenation and active ventilation of newborn infants. The behavior of the resuscitating person is not always consistent. Some tend to use the front or the rear part of the SIBMS for passive oxygenation, ventilate at higher rates and increase the oxygen flow rate (OFR) attached to the bag in an attempt to increase the FiO2 delivered to the infant. Trying to know which of these is an ideal practice, we planned to study the FiO2 from the front and rear parts of different brands of SIBMS with different OFR (2, 4, 6, 8 and 10 L/min) and from the front part using same OFR and different ventilation rates (30 and 60/minute). Available SIBMS fall broadly into two categories. In type I, oxygen source is to be connected to a disc at the rear of SIBMS, parallel to its longitudinal axis. The disc can be rotated; oxygen source then faces either a hole (I-hole) or a ridge (I-ridge) in disc. In type II, the source is attached to the rear part at right angle to the longitudinal axis of the set which has no ridge or hole structures. The first group is represented by brand ‘VBM’ (Germany), the second by brand ‘Ambu’ (U.S.A.). The dimensions and volume of the 2 sets were nearly the same. An oxygen analyzer was used to measure the FiO2 at different OFR supplied by 100% oxygen source.
- 24 October 2005
- Published by Oxford University Press (OUP) in Journal of Tropical Pediatrics
- Vol. 52 (5) , 382
Open AccessThe Rear or the Front in Bag and Mask Oxygenation of the Neonates
Different methods and different self-inflating bag and mask sets (SIBMS) are used for passive oxygenation and active ventilation of newborn infants. The behavior of the resuscitating person is not always consistent. Some tend to use the front or the rear part of the SIBMS for passive oxygenation, ventilate at higher rates and increase the oxygen flow rate (OFR) attached to the bag in an attempt to increase the FiO2 delivered to the infant. Trying to know which of these is an ideal practice, we planned to study the FiO2 from the front and rear parts of different brands of SIBMS with different OFR (2, 4, 6, 8 and 10 L/min) and from the front part using same OFR and different ventilation rates (30 and 60/minute). Available SIBMS fall broadly into two categories. In type I, oxygen source is to be connected to a disc at the rear of SIBMS, parallel to its longitudinal axis. The disc can be rotated; oxygen source then faces either a hole (I-hole) or a ridge (I-ridge) in disc. In type II, the source is attached to the rear part at right angle to the longitudinal axis of the set which has no ridge or hole structures. The first group is represented by brand ‘VBM’ (Germany), the second by brand ‘Ambu’ (U.S.A.). The dimensions and volume of the 2 sets were nearly the same. An oxygen analyzer was used to measure the FiO2 at different OFR supplied by 100% oxygen source.
- 9 August 2005
- Published by Springer Nature in Pediatric Cardiology
- Vol. 26 (6) , 832-835
Combining Pulse Oximetry and Clinical Examination in Screening for Congenital Heart Disease
The objective of this study was to evaluate combined pulse oximetry and clinical examination as a screening method for congenital heart disease (CHD) in asymptomatic newborns. Asymptomatic newborns were screened for CHD using pulse oximetry and clinical examination before their discharge from the nursery. Oxygen saturation ≥94% was considered normal. Echocardiography was done for newborns with abnormal readings and for those with significant murmurs. Data concerning undetected cases were collected from the pediatric referral hospital. A total of 5211 cases were screened. Echocardiographic evaluations were done based on low pulse oximetry in five cases and on murmur detection in ten others. The sensitivity of the combined method of screening was 77%, whereas it was 31% for oximetry alone and 46% for clinical examination alone. Specificity was ∼100% for all methods. The positive predictive value of the combined tool was 66.7%. We conclude that combining pulse oximetry and clinical examination can enhance the clinician’s ability to detect life-threatening CHD in a timely manner. This screening method should become a part of the discharge plan for every newborn.
- 9 August 2005
- Published by Springer Nature in Pediatric Cardiology
- Vol. 26 (6) , 832-835
Combining Pulse Oximetry and Clinical Examination in Screening for Congenital Heart Disease
The objective of this study was to evaluate combined pulse oximetry and clinical examination as a screening method for congenital heart disease (CHD) in asymptomatic newborns. Asymptomatic newborns were screened for CHD using pulse oximetry and clinical examination before their discharge from the nursery. Oxygen saturation ≥94% was considered normal. Echocardiography was done for newborns with abnormal readings and for those with significant murmurs. Data concerning undetected cases were collected from the pediatric referral hospital. A total of 5211 cases were screened. Echocardiographic evaluations were done based on low pulse oximetry in five cases and on murmur detection in ten others. The sensitivity of the combined method of screening was 77%, whereas it was 31% for oximetry alone and 46% for clinical examination alone. Specificity was ∼100% for all methods. The positive predictive value of the combined tool was 66.7%. We conclude that combining pulse oximetry and clinical examination can enhance the clinician’s ability to detect life-threatening CHD in a timely manner. This screening method should become a part of the discharge plan for every newborn.
- 1 August 2005
- Published by Elsevier in Resuscitation
- Vol. 66 (2) , 217-223
Oxygen concentrations at the rear and front of the bag in bag valve mask devices during oxygenation of neonates
- 1 August 2005
- Published by Elsevier in Resuscitation
- Vol. 66 (2) , 217-223
Oxygen concentrations at the rear and front of the bag in bag valve mask devices during oxygenation of neonates
- 1 July 2005
- Published by SAGE Publications in Journal of Women's Health
- Vol. 14 (6) , 496-501
Effect of Predelivery Vaginal Antisepsis on Maternal and Neonatal Morbidity and Mortality in Egypt
The objective of this study was to determine if cleansing the birth canal with an antiseptic solution at delivery reduces infections in mothers and their newborn babies. Women giving birth in the University Hospital, Alexandria, and their newborns were studied. No intervention for 3 months was followed by 3 months of intervention. Intervention consisted of manually wiping the maternal birth canal with a 0.25% chlorhexidine solution at admission and at every vaginal examination before delivery. Babies were also wiped with chlorhexidine. The study enrolled 4415 women and 4431 newborns. The nonintervention phase comprised 2128 mothers and 2138 newborns, and 2287 mothers and 2293 babies were enrolled in the intervention phase. There were no adverse reactions related to the intervention among the mothers or their children. There was no difference in the overall number of neonatal admissions in both groups, but the admissions because of infection, deaths, and mortalities from infection were significantly less in the intervention group. Among mothers receiving the intervention, admissions, deaths, and infections were significantly reduced. Cleansing the birth canal with chlorhexidine reduced neonatal and maternal postpartum infections. The safety, simplicity, and low cost of the procedure suggest that it should be considered standard care for the reduction of infant and maternal morbidity and mortality.
- 1 July 2005
- Published by SAGE Publications in Journal of Women's Health
- Vol. 14 (6) , 496-501
Effect of Predelivery Vaginal Antisepsis on Maternal and Neonatal Morbidity and Mortality in Egypt
The objective of this study was to determine if cleansing the birth canal with an antiseptic solution at delivery reduces infections in mothers and their newborn babies. Women giving birth in the University Hospital, Alexandria, and their newborns were studied. No intervention for 3 months was followed by 3 months of intervention. Intervention consisted of manually wiping the maternal birth canal with a 0.25% chlorhexidine solution at admission and at every vaginal examination before delivery. Babies were also wiped with chlorhexidine. The study enrolled 4415 women and 4431 newborns. The nonintervention phase comprised 2128 mothers and 2138 newborns, and 2287 mothers and 2293 babies were enrolled in the intervention phase. There were no adverse reactions related to the intervention among the mothers or their children. There was no difference in the overall number of neonatal admissions in both groups, but the admissions because of infection, deaths, and mortalities from infection were significantly less in the intervention group. Among mothers receiving the intervention, admissions, deaths, and infections were significantly reduced. Cleansing the birth canal with chlorhexidine reduced neonatal and maternal postpartum infections. The safety, simplicity, and low cost of the procedure suggest that it should be considered standard care for the reduction of infant and maternal morbidity and mortality.
- 10 June 2005
- Published by Springer Nature in Pediatric Nephrology
- Vol. 20 (9) , 1249-1252
Prophylactic theophylline to prevent renal dysfunction in newborns exposed to perinatal asphyxia—a study in a developing country
Renal damage frequently complicates perinatal asphyxia. Renal vasoconstriction due to adenosine metabolite leads to a fall in glomerular filtration rate (GFR) and filtration fraction. This might be inhibited by the nonspecific adenosine receptor antagonist, theophylline. This study was designed to determine whether theophylline could prevent and/or ameliorate renal dysfunction in term neonates with perinatal asphyxia. We randomized 40 severely asphyxiated term infants to receive intravenously a single dose of either theophylline (5 mg/kg; study group: n=20) or placebo (control group: n=20) during the first hour of life. Fluid intake, urine output, serum creatinine, creatinine clearance, GFR, urinary β2 microglobulin (β2 M) and sodium excretion were recorded during the first 5 days of life. The two groups were comparable. No significant difference was reported regarding mechanical ventilatory support, respiratory complications and seizures. Severe renal dysfunction was significantly higher in the control group. Serum creatinine values were less, and creatinine clearance and GFR were significantly higher in the theophylline group from the second day onwards. β2 M excretion was significantly less in the theophylline group, while sodium excretion and hematuria showed no significant difference. Prophylactic theophylline treatment, given early after birth, has beneficial effects in reducing the renal involvement in asphyxiated full-term infants, with no significant changes in central nervous system involvement.
- 10 June 2005
- Published by Springer Nature in Pediatric Nephrology
- Vol. 20 (9) , 1249-1252
Prophylactic theophylline to prevent renal dysfunction in newborns exposed to perinatal asphyxia—a study in a developing country
Renal damage frequently complicates perinatal asphyxia. Renal vasoconstriction due to adenosine metabolite leads to a fall in glomerular filtration rate (GFR) and filtration fraction. This might be inhibited by the nonspecific adenosine receptor antagonist, theophylline. This study was designed to determine whether theophylline could prevent and/or ameliorate renal dysfunction in term neonates with perinatal asphyxia. We randomized 40 severely asphyxiated term infants to receive intravenously a single dose of either theophylline (5 mg/kg; study group: n=20) or placebo (control group: n=20) during the first hour of life. Fluid intake, urine output, serum creatinine, creatinine clearance, GFR, urinary β2 microglobulin (β2 M) and sodium excretion were recorded during the first 5 days of life. The two groups were comparable. No significant difference was reported regarding mechanical ventilatory support, respiratory complications and seizures. Severe renal dysfunction was significantly higher in the control group. Serum creatinine values were less, and creatinine clearance and GFR were significantly higher in the theophylline group from the second day onwards. β2 M excretion was significantly less in the theophylline group, while sodium excretion and hematuria showed no significant difference. Prophylactic theophylline treatment, given early after birth, has beneficial effects in reducing the renal involvement in asphyxiated full-term infants, with no significant changes in central nervous system involvement.
- Open Access
- 1 June 2005
- Published by Oxford University Press (OUP) in Journal of Tropical Pediatrics
- Vol. 51 (3) , 170-173
Normal Values of Pulse Oximetry in Newborns at High Altitude
The aim of the study was to establish normal values of pulse oximetry saturation, respiratory rate, heart rate, and blood pressure in healthy newborns at high altitude. Vital signs and oximetry saturation readings were collected from healthy term newborns at birth, at 1 h, and at 24 h of life. These were analyzed and compared with reference ranges at sea level. This study was carried out at altitudes of 1640 m above sea level in Taif city, Saudi Arabia. A total of 6011 term newborns were examined at birth and 1 h and 4274 were examined at 24 h of life. At birth, the mean SpO2 was 68.6 per cent and 60.3 per cent from the right upper and lower limbs, respectively. Mean SpO2 was 94.3 per cent and 95.4 per cent at the age of 1 and 24 h, respectively. These values were significantly lower than those reported at sea level. The mean respiratory rate, heart rate, and mean blood pressure at 24 h were 45.7/min, 149.7/min, and 46.9 mmHg, respectively. It is concluded that pulse oximetry saturation for newborn babies is lower at higher altitudes than at sea level. This effect is observable at altitudes of 1600 m above sea level. Cut-off levels lower than those used at sea level should be adopted when dealing with newborns living at high altitudes.
- 1 June 2005
- Published by Oxford University Press (OUP) in Journal of Tropical Pediatrics
- Vol. 51 (3) , 170-173
Open AccessNormal Values of Pulse Oximetry in Newborns at High Altitude
The aim of the study was to establish normal values of pulse oximetry saturation, respiratory rate, heart rate, and blood pressure in healthy newborns at high altitude. Vital signs and oximetry saturation readings were collected from healthy term newborns at birth, at 1 h, and at 24 h of life. These were analyzed and compared with reference ranges at sea level. This study was carried out at altitudes of 1640 m above sea level in Taif city, Saudi Arabia. A total of 6011 term newborns were examined at birth and 1 h and 4274 were examined at 24 h of life. At birth, the mean SpO2 was 68.6 per cent and 60.3 per cent from the right upper and lower limbs, respectively. Mean SpO2 was 94.3 per cent and 95.4 per cent at the age of 1 and 24 h, respectively. These values were significantly lower than those reported at sea level. The mean respiratory rate, heart rate, and mean blood pressure at 24 h were 45.7/min, 149.7/min, and 46.9 mmHg, respectively. It is concluded that pulse oximetry saturation for newborn babies is lower at higher altitudes than at sea level. This effect is observable at altitudes of 1600 m above sea level. Cut-off levels lower than those used at sea level should be adopted when dealing with newborns living at high altitudes.