JKJoachim Klisch

Joachim Klisch

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joachim Klisch has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Woven EndoBridge Cerebral Aneurysm Embolization Device (WEB II): initial clinical experience

    by Joachim Klisch, Vojtech Sychra, Christoph Strasilla, Thomas Liebig, David Fiorella

    The Woven Endobridge (WEB II) device (Sequent Medical, Inc., Aliso Viejo, CA, USA) is an intra-saccular, oblate, braided-wire embolization device designed to provide flow disruption at the aneurysm neck–parent artery interface. The purpose of this study was to evaluate the acute and short-term performance of the WEB II device regarding the immediacy, degree, and durability of aneurysm occlusion in two patients. The WEB II device was implanted in one patient with an unruptured MCA trifurcation aneurysm and one patient with an unruptured basilar tip aneurysm. The degree of intra-aneurysmal flow disruption was graded based on serial digital subtraction aneurysm angiography performed over 30 min immediately following device implantation and at 8 weeks. Immediate and 8-week post-treatment CT and 3-T MRI studies were also performed. Delivery and deployment of the WEB II device was technically straightforward and achieved without complications. Neither device required retrieval or repositioning after full deployment. There were no peri-procedural thrombembolic or hemorrhagic complications. In both cases, complete aneurysm occlusion was observed within minutes of device deployment. Short-term angiographic follow-up confirmed stable complete occlusion at 8 weeks. Early technical and clinical results from the first WEB II cases have been encouraging and suggest that the intra-saccular deployment of self-expanding, compliant, cylindrical, high-density, braided metallic mesh constructs may represent a feasible approach for the endovascular treatment of cerebral aneurysms.


  • Waffle-cone technique with Solitaire™ AB Remodeling Device: endovascular treatment of highly selected complex cerebral aneurysms

    by Vojtech Sychra, Joachim Klisch, Maren Werner, Christian Dettenborn, Alexander Petrovitch, Christoph Strasilla, Rüdiger Gerlach, Steffen Rosahl, Markus Holtmannspötter

    To evaluate patients with complex aneurysms who underwent waffle-cone stent-assisted coil embolization. From February 2008 to February 2010, consecutive data were collected from 80 patients with aneurysms treated with the Solitaire™ AB Remodeling Device followed by a standard coiling procedure using bare or/and bioactive coils. Six of these patients were treated using the “waffle-cone-technique” placing the distal end of a stent directly into the base of a bifurcation aneurysm and coiling through the expanded and cone-shaped distal end of the stent allowing for preservation of parent artery patency. The aneurysms were located at the P3 segment of the posterior cerebral artery (n = 1), the middle cerebral artery bifurcation (n = 1), the basilar tip (n = 2), and the AComAnt (n = 2). Four patients underwent follow-up (2–7 months, mean 4.5 months). Waffle-cone positioning of the Solitaire™ AB Remodeling Device was obtained in all cases without technical problems. No permanent procedural morbidity was observed. In all patients, a Raymond class 2 occlusion was obtained and five patients left the hospital with a good clinical status (mRS0 n = 3, mRS1 n = 1) or no new neurologic deficits (mRS4 n = 1). One patient with SAH III died due to severe vasospasms. Due to major recanalization during follow-up, retreatment was necessary or is planned in four cases; one asymptomatic intimal hyperplasia was observed 8 weeks after initial treatment. The waffle-cone technique may enhance the possibilities of the endovascular treatment of these complex aneurysms. Due to the high rate of recanalization requiring endovascular retreatment, stringent angiographic and clinical follow-up is warranted.


  • Coil embolization of anterior circulation aneurysms supported by the Solitaire™ AB Neurovascular Remodeling Device

    by Joachim Klisch, Christin Clajus, Vojtech Sychra, Cornelia Eger, Christoph Strasilla, Steffen Rosahl, Rüdiger Gerlach, Ingrid Bär, Heinrich Hoch, Uta Herbon, et al.

    Introduction The purpose of the study is to evaluate patients with wide-necked or complex aneurysms of the anterior circulation who underwent Solitaire™ AB Neurovascular Remodeling Device-assisted coil embolization. Methods From February 2008 to March 2009, consecutive data were collected from 45 patients with anterior circulation aneurysms. Eighteen of the patients presented with acute subarachnoid hemorrhage. Forty-six aneurysms were treated with the aid of different applications (n = 49) of the Solitaire™ AB Remodeling Device followed by standard coiling procedure (n = 43) using bioactive coils or/and bare coils. Results Successful positioning of the remodeling device was obtained in 95.9% of the cases. There were two thromboembolic complications (4.1%) and one severe vasospasm requiring retrieval of the device. Permanent procedural morbidity was observed in one patient (2%). The proportion of patients in whom Raymond class 1 occlusion was obtained was 53.5% (n = 23). Raymond class 2 occlusion was achieved in 42% (n = 18) and Raymond class 3 occlusion in 4.7% (n = 2). Thirty-nine patients left the hospital with a good clinical status. Conclusion The initial technical and clinical results of Solitaire™ AB device-assisted coiling of aneurysms in the anterior circulation are highly encouraging. This technique may enhance the possibilities of the endovascular treatment of these aneurysms in clinical routine.