Aidan P. Johnson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aidan P. Johnson has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- James F. Wallman
Faculty of Science, University of Technology Sydney, Ultimo, Australia
5 shared publications Chris O’dOnnell
Monash University/Victorian Institute of Forensic Medicine
2 shared publicationsLyndie Leigh-Shaw
Monash University/Victorian Institute of Forensic Medicine
2 shared publicationsMelanie Archer
Monash University/Victorian Institute of Forensic Medicine
2 shared publications- Katarina Maryann Mikac
AEnvironmental Futures, School of Science, Faculty of Science, Medicine and Health, University of Wollongong, Wollongong, NSW, Australia
1 shared publication Matthew Brown
Department of Forensic Medicine, Monash University/Victorian Institute of Forensic Medicine, Southbank, Australia
1 shared publication
Latest Publications
- 1 August 2014
- Published by Elsevier in Forensic Science International
- Vol. 241, 141-149
Effect of massing on larval growth rate
- 1 August 2014
- Published by Elsevier in Forensic Science International
- Vol. 241, 141-149
Effect of massing on larval growth rate
- 1 September 2013
- Published by Elsevier in Forensic Science International
- Vol. 231 (1-3) , 271-277
Thermogenesis in decomposing carcasses
- 1 September 2013
- Published by Elsevier in Forensic Science International
- Vol. 231 (1-3) , 271-277
Thermogenesis in decomposing carcasses
- 4 June 2013
- Published by Taylor & Francis in Australian Journal of Forensic Sciences
- Vol. 46 (1) , 73-79
Infrared imaging as a non-invasive tool for documenting maggot mass temperatures
Forensic entomology relies on the ability to predict the temperatures to which maggots have been exposed, due to the resultant impact on their growth rate. Mercury thermometers and electrical temperature sensors have traditionally been used to record temperatures of maggot masses, cadavers and the surrounding soil and air. However, these techniques are limited to one measurement at a time and thus may not accurately describe the complexities of the thermal environment of the cadaver. Infrared imaging has gained increasing popularity because of its resolution, affordability and portability. Using decomposing pig carcasses, the current study showed that surface temperature measurements recorded using temperature loggers are able to be successfully replicated by taking spot measurements from an infrared image. Additionally, by recording the maximum temperature observed within each infrared image, an accurate proxy was achieved for internal temperatures of a carcass placed outdoors (R2=0.46, pR2=0.98, p<0.001). This successful characterisation of maggot mass temperatures within carcasses should encourage the application of infrared imaging in forensic entomology research and casework.
- 4 June 2013
- Published by Taylor & Francis in Australian Journal of Forensic Sciences
- Vol. 46 (1) , 73-79
Infrared imaging as a non-invasive tool for documenting maggot mass temperatures
Forensic entomology relies on the ability to predict the temperatures to which maggots have been exposed, due to the resultant impact on their growth rate. Mercury thermometers and electrical temperature sensors have traditionally been used to record temperatures of maggot masses, cadavers and the surrounding soil and air. However, these techniques are limited to one measurement at a time and thus may not accurately describe the complexities of the thermal environment of the cadaver. Infrared imaging has gained increasing popularity because of its resolution, affordability and portability. Using decomposing pig carcasses, the current study showed that surface temperature measurements recorded using temperature loggers are able to be successfully replicated by taking spot measurements from an infrared image. Additionally, by recording the maximum temperature observed within each infrared image, an accurate proxy was achieved for internal temperatures of a carcass placed outdoors (R2=0.46, pR2=0.98, p<0.001). This successful characterisation of maggot mass temperatures within carcasses should encourage the application of infrared imaging in forensic entomology research and casework.
- 26 May 2012
- Published by Springer Nature in International journal of legal medicine
- Vol. 126 (5) , 693-702
Examination of forensic entomology evidence using computed tomography scanning: case studies and refinement of techniques for estimating maggot mass volumes in bodies
A new technique has recently been developed for estimating the volume of maggot masses on deceased persons using post-mortem CT scans. This allows volume to be measured non-invasively and factored into maggot mass temperature calculations for both casework and research. Examination of admission scans also allows exploration of entomological evidence in anatomical areas not usually exposed by autopsy (e.g. nasal cavities and facial sinuses), and before autopsy disrupts the maggot distribution on a body. This paper expands on work already completed by providing the x-ray attenuation coefficient by way of Hounsfield unit (HU) values for various maggot species, maggot masses and human tissue adjacent to masses. Specifically, this study looked at the HU values for four forensically important blowfly larvae: Lucilia cuprina, L. sericata, Calliphora stygia and C. vicina. The Calliphora species had significantly lower HU values than the Lucilia species. This might be explained by histological analysis, which revealed a non-significant trend, suggesting that Calliphora maggots have a higher fat content than the Lucilia maggots. It is apparent that the variation in the x-ray attenuation coefficient usually precludes its use as a tool for delineating the maggot mass from human tissue and that morphology is the dominant method for delineating a mass. This paper also includes three case studies, which reveal different applications for interpreting entomological evidence using post-mortem CT scans.
- 26 May 2012
- Published by Springer Nature in International journal of legal medicine
- Vol. 126 (5) , 693-702
Examination of forensic entomology evidence using computed tomography scanning: case studies and refinement of techniques for estimating maggot mass volumes in bodies
A new technique has recently been developed for estimating the volume of maggot masses on deceased persons using post-mortem CT scans. This allows volume to be measured non-invasively and factored into maggot mass temperature calculations for both casework and research. Examination of admission scans also allows exploration of entomological evidence in anatomical areas not usually exposed by autopsy (e.g. nasal cavities and facial sinuses), and before autopsy disrupts the maggot distribution on a body. This paper expands on work already completed by providing the x-ray attenuation coefficient by way of Hounsfield unit (HU) values for various maggot species, maggot masses and human tissue adjacent to masses. Specifically, this study looked at the HU values for four forensically important blowfly larvae: Lucilia cuprina, L. sericata, Calliphora stygia and C. vicina. The Calliphora species had significantly lower HU values than the Lucilia species. This might be explained by histological analysis, which revealed a non-significant trend, suggesting that Calliphora maggots have a higher fat content than the Lucilia maggots. It is apparent that the variation in the x-ray attenuation coefficient usually precludes its use as a tool for delineating the maggot mass from human tissue and that morphology is the dominant method for delineating a mass. This paper also includes three case studies, which reveal different applications for interpreting entomological evidence using post-mortem CT scans.
- 2 February 2012
- Published by Springer Nature in International journal of legal medicine
- Vol. 127 (1) , 185-194
Non-invasive visualisation and volume estimation of maggot masses using computed tomography scanning
There is limited understanding of the actual temperatures that maggots experience during growth. The impact of maggot mass heating on their growth rates cannot be properly factored into maggot growth rate models, thus limiting the accuracy of forensic entomology estimates. One of the major factors contributing to mass heating is the mass size; however, measuring mass volume is problematic as masses quickly become disturbed when probing them to measure their depth and width. Furthermore, many masses are deep within the body cavity and are inaccessible. This study examined the development of a non-invasive means for measuring mass volume using computed tomography (CT) scanning. It was found that CT can be used to visualise and measure the volume of maggot masses, and a series of rules for doing so were established. The level of agreement between mass measurements made by four ‘judges’ using CT volumetric analysis tools produced excellent reliability (ICC > 0.95). This high level of reliability was maintained when applied to masses of different sizes in experimental cups of meat and natural masses of mixed species on human bodies. Entomological features of mortuary CT scans are now routinely reported in forensic entomology casework in Victoria, Australia, as a result of our work.
- 2 February 2012
- Published by Springer Nature in International journal of legal medicine
- Vol. 127 (1) , 185-194
Non-invasive visualisation and volume estimation of maggot masses using computed tomography scanning
There is limited understanding of the actual temperatures that maggots experience during growth. The impact of maggot mass heating on their growth rates cannot be properly factored into maggot growth rate models, thus limiting the accuracy of forensic entomology estimates. One of the major factors contributing to mass heating is the mass size; however, measuring mass volume is problematic as masses quickly become disturbed when probing them to measure their depth and width. Furthermore, many masses are deep within the body cavity and are inaccessible. This study examined the development of a non-invasive means for measuring mass volume using computed tomography (CT) scanning. It was found that CT can be used to visualise and measure the volume of maggot masses, and a series of rules for doing so were established. The level of agreement between mass measurements made by four ‘judges’ using CT volumetric analysis tools produced excellent reliability (ICC > 0.95). This high level of reliability was maintained when applied to masses of different sizes in experimental cups of meat and natural masses of mixed species on human bodies. Entomological features of mortuary CT scans are now routinely reported in forensic entomology casework in Victoria, Australia, as a result of our work.