Yung Nio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yung Nio has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
A. H. de Vries
Department of Radiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
1 shared publicationC Verhoef
1 shared publicationE F I Comans
1 shared publicationJ Stoker
1 shared publicationJ. Stoker
Department of Radiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
1 shared publicationJaap Stoker
1 shared publication
Latest Publications
- 1 January 2012
- Vol. 70 (1) , 26-34
Imaging modalities for the staging of patients with colorectal cancer.
Dutch guidelines made the following recommendations for staging colorectal cancer (CRC). For liver metastases, computed tomography (CT) or magnetic resonance imaging (MRI) could be used. For lung metastases, imaging could be limited to chest X-ray. The primary aim of this survey was to summarise the use of imaging modalities and the variation in techniques. Three surveys were created and sent to three groups of medical specialists, namely surgeons, radiologists and nuclear medicine physicians. The management survey included questions on the role of different modalities for evaluation of synchronous liver, lung and extrahepatic metastases. The radiological survey included questions concerning the technical aspects of ultrasound (US), CT and MRI. The nuclear medicine survey included questions concerning the technical aspects of FDG-PET and FDG-PET/CT. The management and radiological surveys were sent to abdominal surgeons and abdominal radiologists within 88 hospitals and the nuclear medicine survey to specialists within 34 hospitals. Response rates were 75.0% (n=66/88), 77.3% (n=68/88) and 64.7% (n=22/34) for the management, radiological and nuclear medicine surveys, respectively. For liver metastases, the first modality of choice was CT in 52 (78.8%) and US in 12 hospitals (18.2%). Lung metastases were evaluated by either chest X-ray or chest CT and extrahepatic metastases mainly by CT (n=55). In the radiological and nuclear medicine surveys, some variations in techniques of US, CT, MRI , FDG-PET and FDG-PET/CT were seen. CT is primarily used for liver and extrahepatic metastases and both chest CT and chest X-ray for lung metastases. There are discrepancies between the survey of daily practice and the present guidelines. Comparative studies on different staging strategies for colon and rectal cancer, including comparing a strategy of CT liver/abdomen versus MRI liver/abdomen for the evaluation of liver and extrahepatic disease and chest X-ray or chest CT for lung metastases would be important for well-founded adjustments of the present guidelines.
- 1 January 2012
- Vol. 70 (1) , 26-34
Imaging modalities for the staging of patients with colorectal cancer.
Dutch guidelines made the following recommendations for staging colorectal cancer (CRC). For liver metastases, computed tomography (CT) or magnetic resonance imaging (MRI) could be used. For lung metastases, imaging could be limited to chest X-ray. The primary aim of this survey was to summarise the use of imaging modalities and the variation in techniques. Three surveys were created and sent to three groups of medical specialists, namely surgeons, radiologists and nuclear medicine physicians. The management survey included questions on the role of different modalities for evaluation of synchronous liver, lung and extrahepatic metastases. The radiological survey included questions concerning the technical aspects of ultrasound (US), CT and MRI. The nuclear medicine survey included questions concerning the technical aspects of FDG-PET and FDG-PET/CT. The management and radiological surveys were sent to abdominal surgeons and abdominal radiologists within 88 hospitals and the nuclear medicine survey to specialists within 34 hospitals. Response rates were 75.0% (n=66/88), 77.3% (n=68/88) and 64.7% (n=22/34) for the management, radiological and nuclear medicine surveys, respectively. For liver metastases, the first modality of choice was CT in 52 (78.8%) and US in 12 hospitals (18.2%). Lung metastases were evaluated by either chest X-ray or chest CT and extrahepatic metastases mainly by CT (n=55). In the radiological and nuclear medicine surveys, some variations in techniques of US, CT, MRI , FDG-PET and FDG-PET/CT were seen. CT is primarily used for liver and extrahepatic metastases and both chest CT and chest X-ray for lung metastases. There are discrepancies between the survey of daily practice and the present guidelines. Comparative studies on different staging strategies for colon and rectal cancer, including comparing a strategy of CT liver/abdomen versus MRI liver/abdomen for the evaluation of liver and extrahepatic disease and chest X-ray or chest CT for lung metastases would be important for well-founded adjustments of the present guidelines.
- 8 December 2006
- Published by Springer Nature in Abdominal Radiology
- Vol. 32 (5) , 556-570
Perceptive errors in CT colonography
- 8 December 2006
- Published by Springer Nature in Abdominal Radiology
- Vol. 32 (5) , 556-570
Perceptive errors in CT colonography
- 1 January 2006
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 41 (243) , 139-145
Computed tomography colonography: Current issues
OBJECTIVE: Direct and indirect evidence supports the concept of screening for adenomas and early stage colorectal cancer in reducing the incidence and disease-specific mortality. Controversy remains as to the appropriateness of and preferred methods for screening an asymptomatic population. METHODS: Review of computed tomography (CT) colonography based on the literature and personal experience. RESULTS AND CONCLUSIONS: Current discrepancies in the data on accuracy and patient acceptance of CT colonography reflect differences in the performance and evaluation of this examination. Before CT colonography can be implemented in colorectal cancer screening, factors that cause this variability must be elucidated. Studies in which high-resolution scanning, three-dimensional review methods and an enhanced colonoscopic reference are used achieve an accuracy that is similar to colonoscopy. At the same time the evidence that ultra-low radiation dose CT colonography is feasible is mounting, a development that dramatically reduces one of the largest obstacles for large-scale application of this techniqu
- 1 January 2006
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 41 (243) , 139-145
Computed tomography colonography: Current issues
OBJECTIVE: Direct and indirect evidence supports the concept of screening for adenomas and early stage colorectal cancer in reducing the incidence and disease-specific mortality. Controversy remains as to the appropriateness of and preferred methods for screening an asymptomatic population. METHODS: Review of computed tomography (CT) colonography based on the literature and personal experience. RESULTS AND CONCLUSIONS: Current discrepancies in the data on accuracy and patient acceptance of CT colonography reflect differences in the performance and evaluation of this examination. Before CT colonography can be implemented in colorectal cancer screening, factors that cause this variability must be elucidated. Studies in which high-resolution scanning, three-dimensional review methods and an enhanced colonoscopic reference are used achieve an accuracy that is similar to colonoscopy. At the same time the evidence that ultra-low radiation dose CT colonography is feasible is mounting, a development that dramatically reduces one of the largest obstacles for large-scale application of this techniqu