Franz Kralinger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Franz Kralinger has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
C. Haid
Department of Trauma and Sports, University Hospital Innsbruck, Innsbruck, Austria
2 shared publicationsM. Gschwentner
Department of Trauma and Sports, University Hospital Innsbruck, Innsbruck, Austria
2 shared publicationsM. Wambacher
Department of Trauma and Sports, University Hospital Innsbruck, Innsbruck, Austria
2 shared publicationsV. Smekal
Department of Trauma and Sports, University Hospital Innsbruck, Innsbruck, Austria
2 shared publicationsAndreas Platz
Department of General, Hand, and Trauma Surgery, Stadtspital Triemli, Birmensdorferstr. 497, CH-8063 Zürich, Switzerland
1 shared publication- Armin Suckert
Department of Trauma surgery and Sports Medicine, Innsbruck Medical University, Innsbruck, Austria
1 shared publication
Latest Publications
- 18 June 2014
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 96 (12) , 1026-1032
The Influence of Local Bone Density on the Outcome of One Hundred and Fifty Proximal Humeral Fractures Treated with a Locking Plate
Methods: We enrolled 150 patients who were from fifty to ninety years old with a closed, displaced proximal humeral fracture fixed with use of a locking plate from July 2007 to April 2010. There were 118 women and thirty-two men who had a mean age of sixty-nine years. Preoperative computed tomography (CT) scans were done to assess bone mineral density of the contralateral humerus, and dual x-ray absorptiometry of the distal end of the radius of the unaffected arm was conducted within the first six weeks postoperatively. At follow-up evaluations at six weeks, three months, and one year postoperatively, pain, shoulder mobility, strength, and multiple functional and quality-of-life outcome measures (Disabilities of the Arm, Shoulder and Hand [DASH] questionnaire; Shoulder Pain and Disability Index [SPADI]; Constant score; and EuroQuol-5D [EQ-5D]) were done and standard radiographs were made. We defined mechanical failure as all complications related to bone quality experienced within one year. Results: After locking plate fixation, fifty-three (35%) of 150 patients had mechanical failure; loss of reduction and secondary screw loosening with perforation were common. CT assessments of local bone mineral density showed no difference between patients with and without mechanical failure (89.82 versus 91.51 mg/cm3, respectively; p = 0.670). One-year DASH, SPADI, and Constant scores were significantly better for patients without mechanical failure (p ≤ 0.05). Conclusions: We did not find evidence of an association between bone mineral density and the rate of mechanical failures, which may suggest that patients with normal bone mineral density are less prone to sustain a proximal humeral fracture. Future studies should target other discriminating factors between patients with and without mechanical failure. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence....
- 18 June 2014
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 96 (12) , 1026-1032
The Influence of Local Bone Density on the Outcome of One Hundred and Fifty Proximal Humeral Fractures Treated with a Locking Plate
Methods: We enrolled 150 patients who were from fifty to ninety years old with a closed, displaced proximal humeral fracture fixed with use of a locking plate from July 2007 to April 2010. There were 118 women and thirty-two men who had a mean age of sixty-nine years. Preoperative computed tomography (CT) scans were done to assess bone mineral density of the contralateral humerus, and dual x-ray absorptiometry of the distal end of the radius of the unaffected arm was conducted within the first six weeks postoperatively. At follow-up evaluations at six weeks, three months, and one year postoperatively, pain, shoulder mobility, strength, and multiple functional and quality-of-life outcome measures (Disabilities of the Arm, Shoulder and Hand [DASH] questionnaire; Shoulder Pain and Disability Index [SPADI]; Constant score; and EuroQuol-5D [EQ-5D]) were done and standard radiographs were made. We defined mechanical failure as all complications related to bone quality experienced within one year. Results: After locking plate fixation, fifty-three (35%) of 150 patients had mechanical failure; loss of reduction and secondary screw loosening with perforation were common. CT assessments of local bone mineral density showed no difference between patients with and without mechanical failure (89.82 versus 91.51 mg/cm3, respectively; p = 0.670). One-year DASH, SPADI, and Constant scores were significantly better for patients without mechanical failure (p ≤ 0.05). Conclusions: We did not find evidence of an association between bone mineral density and the rate of mechanical failures, which may suggest that patients with normal bone mineral density are less prone to sustain a proximal humeral fracture. Future studies should target other discriminating factors between patients with and without mechanical failure. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence....
- 21 April 2011
- Published by Springer Nature in Skeletal Radiology
- Vol. 41 (3) , 299-304
Preoperative assessment of the cancellous bone mineral density of the proximal humerus using CT data
Background Osteoporotic fractures of the proximal humerus show an increasing incidence. Osteoporosis not only influences the fracture risk after low-energy trauma, but also affects the mechanical stability of internal fixation. Preoperative assessment of the local bone quality may be useful in the surgical treatment of patients sustaining these injuries. The aim of the present study was to present a method for the preoperative assessment of the local cancellous bone mineral density (BMD) of the proximal humerus using CT data. Methods In the first part of the study, CT scans of 30 patients with unilateral fractures of the proximal humerus after low-energy trauma were used. The local BMD was assessed on the contralateral uninjured side. All 30 patients additionally underwent dual-emission X-ray absorptiometry (DXA) of the lumbar spine, proximal femur, and forearm of the side of the uninjured proximal humerus within 6 weeks after trauma. Three independent trauma surgeons performed measurements on the uninjured proximal humerus twice with a time interval of 4 weeks in order to assess the inter- and intraobserver reliability of the method. In the second part of the study, the local BMD of 507 patients with either proximal humerus fractures or chronic shoulder instability was assessed by a single trauma surgeon. In both parts, the average HU values in standardized ROIs of the humeral head were automatically calculated after correcting for HU values below the water equivalent. A linear calibration equation was computed for the calculation from HU to BMD using a calibration device (EFP). Results The intra- and interobserver reliability was high (ICC > 0.95). Correlation coefficients between the local BMD of the proximal humerus and other anatomical sites were between 0.35 (lumbar spine) and 0.64 (forearm). We found a high correlation between the local BMD and age. The BMD in the fracture group was significantly lower than in the instability group. These patients were significantly older and more likely to be female. Conclusion Our method may provide a preoperative tool for the assessment of the local bone quality of the proximal humerus using CT data. Therapeutic adjustments such as augmentation or primary arthroplasty may be considered in patients with very low local BMD.
- 21 April 2011
- Published by Springer Nature in Skeletal Radiology
- Vol. 41 (3) , 299-304
Preoperative assessment of the cancellous bone mineral density of the proximal humerus using CT data
Background Osteoporotic fractures of the proximal humerus show an increasing incidence. Osteoporosis not only influences the fracture risk after low-energy trauma, but also affects the mechanical stability of internal fixation. Preoperative assessment of the local bone quality may be useful in the surgical treatment of patients sustaining these injuries. The aim of the present study was to present a method for the preoperative assessment of the local cancellous bone mineral density (BMD) of the proximal humerus using CT data. Methods In the first part of the study, CT scans of 30 patients with unilateral fractures of the proximal humerus after low-energy trauma were used. The local BMD was assessed on the contralateral uninjured side. All 30 patients additionally underwent dual-emission X-ray absorptiometry (DXA) of the lumbar spine, proximal femur, and forearm of the side of the uninjured proximal humerus within 6 weeks after trauma. Three independent trauma surgeons performed measurements on the uninjured proximal humerus twice with a time interval of 4 weeks in order to assess the inter- and intraobserver reliability of the method. In the second part of the study, the local BMD of 507 patients with either proximal humerus fractures or chronic shoulder instability was assessed by a single trauma surgeon. In both parts, the average HU values in standardized ROIs of the humeral head were automatically calculated after correcting for HU values below the water equivalent. A linear calibration equation was computed for the calculation from HU to BMD using a calibration device (EFP). Results The intra- and interobserver reliability was high (ICC > 0.95). Correlation coefficients between the local BMD of the proximal humerus and other anatomical sites were between 0.35 (lumbar spine) and 0.64 (forearm). We found a high correlation between the local BMD and age. The BMD in the fracture group was significantly lower than in the instability group. These patients were significantly older and more likely to be female. Conclusion Our method may provide a preoperative tool for the assessment of the local bone quality of the proximal humerus using CT data. Therapeutic adjustments such as augmentation or primary arthroplasty may be considered in patients with very low local BMD.
- Open Access
- 9 November 2010
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 11 (1) , 256
Does osteoporosis increase complication risk in surgical fracture treatment? A protocol combining new endpoints for two prospective multicentre open cohort studies
With an ever-increasing elderly population, orthopaedic surgeons are faced with treating a high number of fragility fractures. Biomechanical tests have demonstrated the potential role of osteoporosis in the increased risk of fracture fixation complications, yet this has not been sufficiently proven in clinical practice. Based on this knowledge, two clinical studies were designed to investigate the influence of local bone quality on the occurrence of complications in elderly patients with distal radius and proximal humerus fractures treated by open reduction and internal fixation.
- 9 November 2010
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 11 (1) , 256
Open AccessDoes osteoporosis increase complication risk in surgical fracture treatment? A protocol combining new endpoints for two prospective multicentre open cohort studies
With an ever-increasing elderly population, orthopaedic surgeons are faced with treating a high number of fragility fractures. Biomechanical tests have demonstrated the potential role of osteoporosis in the increased risk of fracture fixation complications, yet this has not been sufficiently proven in clinical practice. Based on this knowledge, two clinical studies were designed to investigate the influence of local bone quality on the occurrence of complications in elderly patients with distal radius and proximal humerus fractures treated by open reduction and internal fixation.
- 17 June 2008
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 128 (8) , 887
Reply letter to the editor regarding the biomechanical evaluation of semirigid implants
- 17 June 2008
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 128 (8) , 887
Reply letter to the editor regarding the biomechanical evaluation of semirigid implants
- 27 November 2007
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 128 (2) , 205-210
Proximal humeral fractures: what is semi-rigid? Biomechanical properties of semi-rigid implants, a biomechanical cadaver based evaluation
Proximal humerus fractures remain challenging especially in the elderly. Biomechanical data put semi-rigid implants in favour of osteopenic or osteoporotic situation. Little surgical side damage is associated with a minimal invasive approach of these implants. The aim of this study was to evaluate the mechanical properties of three such implants. Fresh frozen cadaver specimens were mounted as proposed by the distributors. Three different implants were used: LCP-PH (locking compression plate proximal humerus, Synthes, Austria), HB (humerus block, Synthes, Austria), and IMC (intramedullary claw, ITS, Austria). Subcapital fracture was simulated by resecting a 5 mm gap. All specimens were comparable in “B” (one), “M” (ineral) and “D” (ensity). Four load cases were tested: varus bending, medial shearing and axial torque. A cyclic test (1,000 cycles) was performed in the first load case (varus stress) for all three implants. The LCP-PH was the most rigid in all three load cases, always followed by the HB. The IMC was the most elastic device with almost immeasurable values in axial torque. In the cyclic setting, the load reduction of the HB followed by the LCP-PH was significantly better than that for the IMC. The differences in stiffness are varying tremendously. The IMC is the implant with the lowest stiffness in all load cases and the highest load reduction. New “semi-rigids” claim good clinical performance, yet prospective clinical studies have to prove this. It is unlikely that the IMC can maintain fracture reduction in fracture situations of complex nature (no ligamentotaxis).
- 27 November 2007
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 128 (2) , 205-210
Proximal humeral fractures: what is semi-rigid? Biomechanical properties of semi-rigid implants, a biomechanical cadaver based evaluation
Proximal humerus fractures remain challenging especially in the elderly. Biomechanical data put semi-rigid implants in favour of osteopenic or osteoporotic situation. Little surgical side damage is associated with a minimal invasive approach of these implants. The aim of this study was to evaluate the mechanical properties of three such implants. Fresh frozen cadaver specimens were mounted as proposed by the distributors. Three different implants were used: LCP-PH (locking compression plate proximal humerus, Synthes, Austria), HB (humerus block, Synthes, Austria), and IMC (intramedullary claw, ITS, Austria). Subcapital fracture was simulated by resecting a 5 mm gap. All specimens were comparable in “B” (one), “M” (ineral) and “D” (ensity). Four load cases were tested: varus bending, medial shearing and axial torque. A cyclic test (1,000 cycles) was performed in the first load case (varus stress) for all three implants. The LCP-PH was the most rigid in all three load cases, always followed by the HB. The IMC was the most elastic device with almost immeasurable values in axial torque. In the cyclic setting, the load reduction of the HB followed by the LCP-PH was significantly better than that for the IMC. The differences in stiffness are varying tremendously. The IMC is the implant with the lowest stiffness in all load cases and the highest load reduction. New “semi-rigids” claim good clinical performance, yet prospective clinical studies have to prove this. It is unlikely that the IMC can maintain fracture reduction in fracture situations of complex nature (no ligamentotaxis).