Anne Bailly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anne Bailly has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
J. Lipiecki
University Hospital
2 shared publicationsJ. Ponsonnaille
University Hospital
2 shared publicationsA. Alfidja
University Hospital
1 shared publication- Boris Jung
Medical Intensive Care Unit, Montpellier University Hospital
1 shared publication - Emmanuel Futier
Departement Anesthésie Réanimation, Centre Hospitalier Universitaire (CHU) Clermont-Ferrand, Clermont-Ferrand, France
1 shared publication J. M. Garcier
University Hospital
1 shared publication
Latest Publications
- 8 October 2008
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 31 (2) , 113-120
Assessment of left ventricular volumes and function by cine-MR imaging depending on the investigator’s experience
To analyze the reproducibility of LV volumes calculated by cardiac magnetic resonance imaging (CMRI) and to compare them to those obtained by conventional ventriculography. A total of 30 patients with stable ischemic heart disease were prospectively included. Each underwent CMRI twice and ventriculography. Left ventricular end diastolic volume (EDV), end systolic volume (ESV) and LV ejection fraction (EF) were calculated by two radiologists at different level of experience. Intraobserver, interobserver and interstudy variabilities were assessed. The cut off values were: intraobserver variability (EDV, ESV, EF): 9.4 ml, 5.3 ml, 3.3% for well-trained radiologist; 13.1 ml, 7.5 ml, 4.1% for less-trained radiologist. interobserver variability: EDV: 11.7 and 10.4 ml; ESV: 7.0 and 6.6 ml; EF: 3.9 and 4.2%. interstudy variability (EDV, ESV, EF): 11.6 and 12.6 ml, 7.1 and 7.4 ml, 3.9 and 3.5%, for experienced and less-trained observers. Statistical differences were found between CMRI and ventriculography: CMRI underestimation of EDV and EF, overestimation of ESV. CMRI volumetric quantification of LV volumes and function is highly reproducible at different levels of experience, but not interchangeable with those obtained by ventriculography.
- 8 October 2008
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 31 (2) , 113-120
Assessment of left ventricular volumes and function by cine-MR imaging depending on the investigator’s experience
To analyze the reproducibility of LV volumes calculated by cardiac magnetic resonance imaging (CMRI) and to compare them to those obtained by conventional ventriculography. A total of 30 patients with stable ischemic heart disease were prospectively included. Each underwent CMRI twice and ventriculography. Left ventricular end diastolic volume (EDV), end systolic volume (ESV) and LV ejection fraction (EF) were calculated by two radiologists at different level of experience. Intraobserver, interobserver and interstudy variabilities were assessed. The cut off values were: intraobserver variability (EDV, ESV, EF): 9.4 ml, 5.3 ml, 3.3% for well-trained radiologist; 13.1 ml, 7.5 ml, 4.1% for less-trained radiologist. interobserver variability: EDV: 11.7 and 10.4 ml; ESV: 7.0 and 6.6 ml; EF: 3.9 and 4.2%. interstudy variability (EDV, ESV, EF): 11.6 and 12.6 ml, 7.1 and 7.4 ml, 3.9 and 3.5%, for experienced and less-trained observers. Statistical differences were found between CMRI and ventriculography: CMRI underestimation of EDV and EF, overestimation of ESV. CMRI volumetric quantification of LV volumes and function is highly reproducible at different levels of experience, but not interchangeable with those obtained by ventriculography.
- Open Access
- 16 April 2008
- Published by Springer Nature in Critical Care
- Vol. 12 (2) , R50
Respiratory effects of different recruitment maneuvers in acute respiratory distress syndrome
Introduction: Alveolar derecruitment may occur during low tidal volume ventilation and may be prevented by recruitment maneuvers (RMs). The aim of this study was to compare two RMs in acute respiratory distress syndrome (ARDS) patients. Methods: Nineteen patients with ARDS and protective ventilation were included in a randomized crossover study. Both RMs were applied in each patient, beginning with either continuous positive airway pressure (CPAP) with 40 cm H2O for 40 seconds or extended sigh (eSigh) consisting of a positive end-expiratory pressure maintained at 10 cm H2O above the lower inflection point of the pressure-volume curve for 15 minutes. Recruited volume, arterial partial pressure of oxygen/fraction of inspired oxygen (PaO2/FiO2), and hemodynamic parameters were recorded before (baseline) and 5 and 60 minutes after RM. All patients had a lung computed tomography (CT) scan before study inclusion. Results: Before RM, PaO2/FiO2 was 151 ± 61 mm Hg. Both RMs increased oxygenation, but the increase in PaO2/FiO2 was significantly higher with eSigh than CPAP at 5 minutes (73% ± 25% versus 44% ± 28%; P < 0.001) and 60 minutes (68% ± 23% versus 35% ± 22%; P < 0.001). Only eSigh significantly increased recruited volume at 5 and 60 minutes (21% ± 22% and 21% ± 25%; P = 0.0003 and P = 0.001, respectively). The only difference between responders and non-responders was CT lung morphology. Eleven patients were considered as recruiters with eSigh (10 with diffuse loss of aeration) and 6 with CPAP (5 with diffuse loss of aeration). During CPAP, 2 patients needed interruption of RM due to a drop in systolic arterial pressure. Conclusion: Both RMs effectively increase oxygenation, but CPAP failed to increase recruited volume. When the lung is recruited with an eSigh adapted for each patient, alveolar recruitment and oxygenation are superior to those observed with CPAP.
- 16 April 2008
- Published by Springer Nature in Critical Care
- Vol. 12 (2) , R50
Open AccessRespiratory effects of different recruitment maneuvers in acute respiratory distress syndrome
Introduction: Alveolar derecruitment may occur during low tidal volume ventilation and may be prevented by recruitment maneuvers (RMs). The aim of this study was to compare two RMs in acute respiratory distress syndrome (ARDS) patients. Methods: Nineteen patients with ARDS and protective ventilation were included in a randomized crossover study. Both RMs were applied in each patient, beginning with either continuous positive airway pressure (CPAP) with 40 cm H2O for 40 seconds or extended sigh (eSigh) consisting of a positive end-expiratory pressure maintained at 10 cm H2O above the lower inflection point of the pressure-volume curve for 15 minutes. Recruited volume, arterial partial pressure of oxygen/fraction of inspired oxygen (PaO2/FiO2), and hemodynamic parameters were recorded before (baseline) and 5 and 60 minutes after RM. All patients had a lung computed tomography (CT) scan before study inclusion. Results: Before RM, PaO2/FiO2 was 151 ± 61 mm Hg. Both RMs increased oxygenation, but the increase in PaO2/FiO2 was significantly higher with eSigh than CPAP at 5 minutes (73% ± 25% versus 44% ± 28%; P < 0.001) and 60 minutes (68% ± 23% versus 35% ± 22%; P < 0.001). Only eSigh significantly increased recruited volume at 5 and 60 minutes (21% ± 22% and 21% ± 25%; P = 0.0003 and P = 0.001, respectively). The only difference between responders and non-responders was CT lung morphology. Eleven patients were considered as recruiters with eSigh (10 with diffuse loss of aeration) and 6 with CPAP (5 with diffuse loss of aeration). During CPAP, 2 patients needed interruption of RM due to a drop in systolic arterial pressure. Conclusion: Both RMs effectively increase oxygenation, but CPAP failed to increase recruited volume. When the lung is recruited with an eSigh adapted for each patient, alveolar recruitment and oxygenation are superior to those observed with CPAP.
- 1 December 2005
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 6
711 The reproducibility of measurements of left ventricular volumes and ejection fraction obtained by magnetic resonance imaging & second harmonic echocardiography in patients with ischemic heart disease
- 1 December 2005
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 6
711 The reproducibility of measurements of left ventricular volumes and ejection fraction obtained by magnetic resonance imaging & second harmonic echocardiography in patients with ischemic heart disease