MSMichael Strotzer

Michael Strotzer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael Strotzer has a total of 65 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Radiologische Implantation zentralvenöser Portsysteme am Unterarm

    by M. Lenhart, S. Schätzler, C. Manke, M. Strotzer, J. Seitz, J. Gmeinwieser, M. Völk, N. Zorger, S. Feuerbach, T. Herold, et al.

    Ziel: Retrospektive Analyse des technischen Erfolgs und der Langzeitkomplikationen von am Unterarm durch Radiologen implantierten zentralvenösen Ports. Patienten und Methode: In einem Zeitraum von 5 Jahren wurden 399 Unterarmports bei 391 Patienten implantiert. Das System besteht aus einer Titankammer und einem Silikonkatheter. Unter Durchleuchtung wurde eine Vene proximal der Ellenbeuge punktiert und die Portkammer nach Tunnelung des Katheters am beugeseitigen Unterarm implantiert. Die Katheterspitze kam in der Vena cava superior zu liegen. Der technische Erfolg und alle in der Liegezeit auftretenden Komplikationen wurden analysiert. Ergebnisse: Bei 391 Patienten wurde eine Katheterliegezeit von 98 633 Tagen dokumentiert (1 – 1325 Tage, Mittelwert 252 Tage). Die Portimplantation war in 396 Fällen primär technisch erfolgreich (99,25 %, 396 / 399). Bei drei Patienten gelang die Implantation zu einem späteren Zeitpunkt. Schwere Komplikationen wie Pneumothorax oder schwere Blutungen traten nicht auf. Insgesamt kam es zu 45 Komplikationen (11,28 %, 0,45 / 1000 Kathetertage). Darunter waren 8 Infektionen des Portlagers (nach 27 – 205, im Durchschnitt 115 Tagen). Fünfzehn Ports wurden wegen Komplikationen entfernt. Die Komplikationsrate deckt sich mit den Angaben über subklavikuläre Ports und liegt zum Großteil unter den Daten, die in etablierten Publikationen chirurgischer Verfahren genannt werden. Schlussfolgerungen: Die radiologische Implantation zentralvenöser Portsysteme am Unterarm ist ein sicheres und minimalinvasives Verfahren mit geringer Komplikationsrate. Schwere Implantationskomplikationen treten nicht auf. Die Langzeitkomplikationen sind mit anderen Studien chirurgischer oder radiologischer Portimplantationen unterschiedlicher Lokalisationen vergleichbar. Purpose: To retrospectively analyze the technical result and long term outcome of central venous arm ports placed by radiologists. Materials and Method: Over a 5-year period, 399 arm ports were implanted by radiologists in 391 patients. The system consists of a low profile titanium chamber and a silicone catheter. Ports were placed at the forearm after puncture of a vein proximally to the elbow under fluoroscopic guidance. In a retrospective analysis the technical results and the long term outcome were evaluated. Complications were documented according to the standards of the society of interventional radiology. Results: In 391 patients a total of 98 633 catheter days were documented (1 – 1325 days, mean 252 days). Primary technical success was 99.25 % (396 / 399) with a 100 % secondary technical success rate. No severe procedural complications, e. g. pneumothorax or severe hemorrhage, were found. A total of 45 complications occurred (11.28 %, 0.45 / 1000 catheter days), including 8 portal pocket infections (27 – 205 days, mean 115 days). Fifteen ports were explanted because of complications. The complication rate corresponds to the data from subclavian ports and is less than the complication rates published in large surgical trials. Conclusion: Implantation of central-venous arm ports by radiologists is safe and minimally invasive. No severe immediate procedural complications occur due to the peripheral implantation site. Long term complication rates are comparable to other studies of radiological or surgical port implantation at different sites.


  • Perkutane Therapie inoperabler maligner Stenosen und Verschlüsse der Gallenwege mit einem neu entwickelten selbstexpandierbaren Nitinolstent (SMART)

    by N. Zorger, M. Lenhart, M. Strotzer, C. Paetzel, O. Hamer, S. Feuerbach, J. Link

    Zielsetzung: Evaluation der technischen Handhabung und Effizienz eines neu entwickelten Stents zur Therapie maligner Gallenwegsstenosen und Verschlüsse. Material und Methodik: In einer prospektiven Studie wurden 25 Patienten mit Verschlussikterus bei maligner Gallengangsstenose palliativ mit dem SMART®-Stent behandelt. Evaluiert wurden die Handhabung des Stents und die Qualität der Stententfaltung. Die Stentfunktion wurde nach 2 - 4 Tagen über eine liegende interne/externe Drainage cholangiographisch sowie anhand des Verlaufs der Laborparameter kontrolliert. Eine zusätzliche Kontrolle der Stentfunktion erfolgte nach drei Monaten. Dabei wurden das subjektive Wohlbefinden des Patienten, der aktuelle Gesamtbilirubinspiegel im Serum und die Anzahl weiterer, im Nachsorgezeitraum durchgeführter Interventionen dokumentiert. Ergebnisse: Alle Läsionen wurden mit durchschnittlich 1,4 Stents erfolgreich behandelt. Bei 14 Patienten erfolgte nach Freisetzung des Stents eine zusätzliche Ballondilatation (8 - 10 mm Durchmesser/ 40 - 80 mm Länge). Der Bilirubinsspiegel sank signifikant von durchschnittlich 11,6 mg/dl auf 4,6 mg/dl nach Intervention (p < 0,05). In der Verlaufskontrolle nach drei Monaten lag der mittlere Bilirubinspiegel bei 4,0 mg/dl. In 4 Fällen (16 %) war eine Reintervention (erneute PTCD oder Stent) aufgrund einer Tumorprogression erfolgt. 6 Patienten waren an ihrer Grunderkrankung verstorben. Bei 15 (79 %) der überlebenden Patienten waren die Stents funktionsfähig. Schlussfolgerung: Die bislang erhobenen Daten zeigen einen guten technischen und klinischen Pimärerfolg bei palliativer Gallengangsstentung mit dem SMART®-Stent. Objective: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. Methods: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART® stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2 - 4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. Results: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8 - 10 mm diameter/ 40 - 80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p < 0.05). The follow-up showed a mean serum bilirubin level at 4.0 mg/dl. In 4 cases (16 %) a further intervention (PTCD or stent) was performed. Six patients died due to tumor progression. The stents proved to be patent in 79 % (n = 15) of patients alive at the time of follow-up. Conclusions: Placement of the SMART stent for the therapy of malignant biliary lesions yields good technical and clinical results.


  • Kontrastmittelverstärkte MR-Angiographie der Becken- und Beingefäße in der klinischen Routinediagnostik

    by M. Lenhart, T. Finkenzeller, C. Paetzel, M. Strotzer, S. Mann, B. Djavidani, W. R. Nitz, J. Link, S. Feuerbach, P. Kasprzak

    Ziel: In einer prospektiven Studie wurde untersucht, ob die kontrastmittelverstärkte MR-Angiographie der Becken- und Beinarterien ausreichende Informationen beinhaltet, um einen Verzicht auf die Katheterangiographie zu rechtfertigen. Material und Methode: In einem Zeitraum von 23 Wochen wurden 100 konsekutive Patienten eingeschlossen. Bei diesen wurden insgesamt 112 Untersuchungen durchgeführt. Die MRA erfolgte in Schrittverschiebetechnik bei 1,5 Tesla mit einem dedizierten Spulensystem. Es wurde dokumentiert, in welchen Fällen die MRA alleine zur Diagnostik ausreichte, und wann weitere Untersuchungen notwendig waren. Ergebnisse: Bei 93,75 % (105/112) der Untersuchungen war die MRA als alleinige Diagnostik vor Intervention oder auch zur postoperativen Kontrolle ausreichend. Bei 22 Patienten wurde entsprechend der MRA eine Intervention bzw. eine Operation durchgeführt, wobei sich die Befunde bestätigten. In 7 Fällen (6,25 %) wurden Nachuntersuchungen durchgeführt. Diese bestanden aus zwei Becken-MRA, einer Unterschenkel-MRA und in 4 Fällen war wegen einer venösen Überlagerung am Unterschenkel eine selektive intraarterielle Angiographie notwendig. Schlussfolgerung: Die kontrastmittelverstärkte MRA der Becken- und Beinarterien ersetzt die Katheterangiographie sowohl in der präinterventionellen als auch in der postoperativen Diagnostik. In der vorliegenden Technik ist mit einer Häufigkeit von 5 - 10 % mit Qualitätseinbußen zu rechnen, die eine weitere, allerdings gezielte Diagnostik erfordern. Purpose: Prospective evaluation of the effectiveness of contrast-enhanced moving-table magnetic resonance angiography (CE-MRA) as the sole routine tool for the diagnosis of peripheral arterial occlusive disease and determination whether it can replace catheter arteriography. Subjects and Methods: In a time period of 23 weeks, 100 consecutive patients were evaluated. A total of 112 contrast-enhanced moving-table MR angiograms were performed at 1.5 Tesla. A dedicated vascular coil system was used. It was evaluated in which cases MR angiography was sufficient to determine the treatment plan and in which cases limited quality required additional examinations. Results: In 93.75 % (105/112) of all examinations, the treatment plan was determined by MRA as the sole diagnostic tool. Twenty-two patients underwent surgery or percutaneous angioplasty based on MRA findings. Additional examinations due to impaired quality were performed in seven (6.25 %) cases: two MR angiographies of the pelvic arteries, one MR angiography of the calf, and four selective arteriographies because of venous overlay at the calf. Conclusion: Contrast-enhanced MR angiography can take the place of catheter angiography in the routine work-up of patients with peripheral arterial occlusive disease. Further assessment might be necessary in five to ten percent of the cases when the diagnostic quality is inadequate, mostly due to venous overlay in the lower leg.


    • 1 November 2001
      • Vol. 42  (6) , 568-73

    Value of high-resolution MR in patients scheduled for cochlear implantation.

    by J Seitz, P Held, A Waldeck, M Strotzer, M Völk, J Strutz, S Feuerbach

    To determine sensitivity and specificity of high-resolution MR imaging and of high-resolution axial CT (HRCT) and to compare the two modalities in predicting the surgical and functional success of cochlear implantation. The presurgical MR images (2D T2W TSE, 3D T2*W CISS, plain and contrast-enhanced 3D T1W MP-RAGE) and axial HRCT findings of 26 patients were evaluated with regard to the predictive value concerning the success of cochlear implantation. We found a high correlation between MR and HRCT and the success of cochlear implantation. In all 26 patients, the MR-based predictions concerning the success of cochlear implantation were correct. In 10 patients, MR gave additional information to HRCT. In all patients, MR gave sufficient information about the status of the inner ear, inner auditory canal and cochlear nerve to aid the surgeon during the operation. A high-resolution MR protocol consisting of coronal 2D T2W TSE, 3D T2*W axial CISS, plain and contrast-enhanced sagittal T1W 3D MP-RAGE is recommended for the evaluation of candidates scheduled for cochlear implantation. It provides information which cannot be obtained by HRCT.


  • Appearance of Vascular Stents in Computed Tomographic Angiography

    by Michael Strotzer, Markus Lenhart, Berhard Butz, Markus Völk, Christoph Manke, Stefan Feuerbach

    Strotzer M, Lenhart M, Butz B, et al. Appearance of vascular stents in computed tomographic angiography: In vitro examination of 14 different stent types. Invest Radiol 2001; 36:652–658. rationale and objectives. To evaluate the appearance of the vessel lumen after implantation of different vascular stents with the use of a computed tomographic (CT) angiography model. methods. A vascular phantom was studied with helical CT and different slice thicknesses (2 and 3 mm) and pitch values (1.0, 1.5, and 2.0). Original transverse CT images and coronal reformations were evaluated. Fourteen different stents were analyzed with regard to changes in the stent lumen (attenuation values, noise, and artificial lumen narrowing). results. Some stents caused artifacts resulting in potential errors during evaluation of their patency. Assessment of the lumen was impaired in two stents (Strecker tantalum and Passager). Increased attenuation values were measured in all stents (increase of 8%–145%). The degree of artificial lumen narrowing was 4.4% to 77.8%. conclusions. In most stents, reliable evaluation of the stent lumen seems possible. However, knowledge of the artifacts caused by different stent types is useful for the assessment of stent patency with CT angiography.


    • 1 May 2001
      • Vol. 22  (5) , 997-1003

    Spinal Metastases from Renal Cell Carcinoma: Effect of Preoperative Particle Embolization on Intraoperative Blood Loss

    by Christoph Manke, Till Bretschneider, Markus Lenhart, Michael Strotzer, Carsten Neumann, Josef Gmeinwieser, Stefan Feuerbach

    BACKGROUND AND PURPOSE: Surgical repair of spinal metastases from renal origin is often complicated by excessive bleeding. The purpose of this study was to assess the effect of preoperative particulate embolization on intraoperative blood loss.


  • Perkutane transfemorale Implantation einer neuen, flexiblen thorakalen Aortenendoprothese unter Verwendung eines perkutanen Nahtsystems zum Gefäßverschluss - erste Erfahrungen

    by C. Manke, R. Kobuch, M. Lenhart, M. Strotzer, J. Merk, F. Birnbaum, S. Feuerbach, J. Link

    Zielsetzung: Evaluation der transfemoralen Implantation einer neuen, flexiblen thorakalen Aortenprothese unter Verwendung eines perkutanen Nahtsystems zum Verschluss des femoralen Zugangs. Patienten und Methoden: Fünf Patienten wurden wegen Aneurysma (n = 3) oder akuter Dissektion (n = 2) der thorakalen Aorta endovaskulär über eine perkutan eingebrachte 24F-Schleuse mit einem Stentgraft versorgt. Der femorale Zugang wurde nach Plazierung der Endoprothese mit zwei perkutanen Nahtgeräten verschlossen. Ergebnisse: Bei allen Patienten führte die Platzierung der Prothese zur Ausschaltung des Aneurysmas oder des falschen Lumens von der Perfusion. Mit der perkutanen Gefäßnaht konnte in allen Fällen ein Verschluss des femoralen Zugangs erreicht werden. In vier Fällen fand sich nach perkutaner Naht angiographisch eine geringgradige Stenosierung der Fermoralarterie. Bis auf ein reversibles Nierenversagen als Folge einer medikamentös induzierten Hypotension im Rahmen der Behandlung einer akuten Aneurysmaruptur traten keine Komplikationen als Folge von Prothesenimplantation oder perkutaner Gefäßnaht auf. Schlussfolgerung: Die perkutane transfemorale Implantation thorakaler Aortenstentgrafts mit perkutaner Naht der Punktionsstelle ist technisch möglich, Langzeitergebnisse der Technik müssen abgewartet werden. Purpose: To evaluate the transfemoral placement of a new, flexible stent-graft into the thoracic aorta and the suture-mediated closure of the femoral access. Patients and Methods: Five patients were treated endovascularly with a stent-graft for an aneurysm (n = 3) or acute dissection (n = 2) of the thoracic aorta via a femoral 24 F sheath. The femoral access site was closed with two suture-mediated closure devices after placement of the stent-graft. Results: The aneurysm or the false lumen was excluded from perfusion by the placement of the stent-graft in all patients. Hemostasis at the femoral access site was successful in all patients with the percutaneous suture device. A minor stenosis of the femoral artery was found angiographically in four patients after suture-mediated closure. Besides a reversible renal failure due to the medically induced hypotension for the treatment of an acutely ruptured aneurysm, no complications resulted from the stent-graft placement or the percutaneous suture. Conclusion: The percutaneous transfemoral placement of stent-grafts in the thoracic aorta using a suture-mediated closure of the access site is technically feasible. Long-term results of the technique have to be awaited.


  • Dynamische MR-Defäkographie zur Diagnostik kombinierter Becken-bodenfunktionsstörungen in der Proktologie

    by C. Paetzel, M. Strotzer, A. Fürst, M. Rentsch, M. Lenhart, S. Feuerbach

    Ziel dieser Studie war die Evaluierung der dynamischen MRT in der proktologischen Diagnostik. Patienten und Methode: In einer prospektiven Studie wurden 36 Patienten (27 Frauen, 9 Männer) mit Beckenbodenfunktionsstörungen an einem 1.5-T-Gerät konsekutiv untersucht. Das Rektum wurde mit 200 ml Ultraschallgel kontrastiert. Verwendet wurde eine T2-gewichtete Gradientenechoseqenz mit einer zeitlichen Auflösung von 1,1 Sekunden in Einzelschichttechnik. Aus den Ergebnissen von MRT und proktologischer Untersuchung wurde eine Konsensdiagnose erstellt, die die Grundlage zur Beurteilung der einzelnen Verfahren darstellte. Ergebnisse: Patienten mit Obstipation (n = 15) zeigten innere Schleimhautvorfälle (n = 5), anteriore Rektozelen (n = 8), Beckenbodendeszensus (n = 5), Enterozelen (n = 2) und anorektale Dyssynergien (n = 3). Bei Patienten mit Stuhlinkontinenz (n = 15) wurden anteriore Rektozelen (n = 10), Beckenbodendeszensus (n = 11), Enterozelen (n = 2), innere Schleimhautvorfälle (n = 1) und eine Insuffizienz der Puborektalisschlinge nachgewiesen. Harninkontinenz war in 10 Fällen mit einer Zystozele und in 4 Fällen mit Normalbefunden im Bereich der Harnblase verbunden. Die Diagnose bei Patienten mit unspezifischen Beschwerden (n = 6) bestanden in anorektaler Dyssynergie (n = 4), innerem Mukosaprolaps (n = 2) und einem Beckenbodendeszensus. Die MRT zeigte sich im Nachweis von Enterozelen, Zystozelen und des Beckenbodendeszensus gegenüber der klinischen Untersuchung überlegen. Schlussfolgerungen: Die dynamische MRT liefert komplexe und therapierelevante Informationen in der Diagnostik von Beckenbodenfunktionsstörungen. Purpose: Evaluation of magnetic resonance defecography in the diagnosis of pelvic floor disorders were examined prospectively. MRI was performed on a 1.5 T scanner. The rectum was opacified with 200 ml of ultrasound transmission gel. A sagittal single section T 2-weighted gradient echo sequence with a temporal resolution of 1.1 second was performed. Changes of the anorectal angle and the position of the pelvic organs in relation to the pubococcygeal line were registered at rest, during straining, and during evacuation of the rectum. Results: Patients with obstructed defecation (n = 15) showed prolapse of the rectal mucosa (n = 5), anterior rectocele (n = 8), pelvic floor descent (n = 5), enterocele (n = 2), and anorectal dyscoordination (n = 3). Individuals with stool incontinence (n = 15) had an anterior rectocele (n = 10), pelvic floor descent (n = 11), enterocele (n = 2), prolapse of rectal mucosa (n = 1), and a puborectal insufficiency (n = 1). Urine incontinence was associated with cystocele (n = 10) or normal findings (n = 4). In patients with unspecific symptoms (n = 6), anorectal dyscoordination (n = 4) and prolapse of the rectal mucosa (n = 2) were found. MRI was superior for the detection of enteroceles, cystoceles and pelvic floor descent compared with clinical investigation. Conclusion: Dynamic MR imaging supplies complex information in anorectal disease and thus improves proctoscopy.