DFDavid Finis

David Finis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David Finis has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Alterations of the outer retina in non‐arteritic anterior ischaemic optic neuropathy detected using spectral‐domain optical coherence tomography

    by Philipp Ackermann, Maike Brachert, Philipp Albrecht, Marius Ringelstein, David Finis, Gerd Geerling, Orhan Aktas, Rainer Guthoff

    Background A characteristic disease pattern may be reflected by retinal layer thickness changes in non‐arteritic anterior ischaemic optic neuropathy measured using spectraldomain optical coherence tomography. Retinal layer segmentation is enabled by advanced software. In this study, retinal layer thicknesses in acute and chronic non‐arteritic anterior ischaemic optic neuropathy were compared. Design A single‐centre cross‐sectional analysis was used. Participants A total of 27 patients (20 age‐matched healthy eyes) were included: 14 with acute (<7 days) and 13 patients with chronic non‐arteritic anterior ischaemic optic neuropathy. Methods Macular volume and 12° peripapillary ring optical coherence tomography scans were used. Main Outcome Measures The peripapillary thicknesses of the following layers were determined by manual segmentation: retinal nerve fibres, ganglion cells + inner plexiform layer, inner nuclear layer + outer plexiform layer, outer nuclear layer + inner segments of the photoreceptors and outer segments of the photoreceptors to Bruch's membrane. Macular retinal layer thicknesses were automatically determined in volume cubes centred on the fovea. Results Peripapillary retinal swelling in acute nonarteritic anterior ischaemic optic neuropathy was attributable to retinal nerve fibre layer, ganglion cell layer/inner plexiform layer and outer nuclear layer/segments of the photoreceptors thickening. In chronic cases, peripapillary retinal nerve fibre layer, macular ganglion cell layer and inner plexiform layer thinning were observed. Conclusions In acute non‐arteritic anterior ischaemic optic neuropathy, the inner and outer peripapillary retinal layers are affected by thickness changes. In chronic cases, atrophy of the ganglion cells and their axons and dendrites is evident by inner retinal layer thinning.


  • Diagnostik von Binde- und Hornhauterkrankungen

    by David Finis, Philipp Ackermann, Stefan Schrader, Gerd Geerling

    In dem vorliegenden Artikel werden gängige Verfahren zur speziellen Hornhautdiagnostik einzeln erläutert und die wichtigsten Messergebnisse dargestellt, sodass der Leser nach Lektüre dieses Beitrags die Verfahren sicher einsetzen kann und mit der Interpretation der Befunde vertraut ist. Wir möchten darauf hinweisen, dass neben den hier in diesem Artikel erläuterten Verfahren weitere Methoden (z. B. Keratometrie, Ästhesiometrie, Ultraschallbiomikroskopie, Fluorophotometrie, Spaltlampenuntersuchung mit Vitalfarbstoffen u. a.) zum Einsatz kommen, die bereits in anderen Artikeln der Reihe erörtert wurden und daher hier nicht detailliert beschrieben werden.

  • Acetazolamide therapy in a case of fingolimod-associated macular edema: early benefits and long-term limitations

    by Katharina Schröder, David Finis, Jens Harmel, Marius Ringelstein, Hans-Peter Hartung, Gerd Geerling, Orhan Aktas, Rainer Guthoff


  • Evaluation eines neuen Weiterbildungsprogramms in der Augenklinik der Heinrich-Heine-Universität Düsseldorf

    by D. Finis, E. Bramann, G. Geerling

    The German ophthalmological training is still a very individually organized system with only one final oral examination at the end of the 5-year residency. At the beginning of 2013 a new residency program was introduced at the department of ophthalmology of the Heinrich-Heine University Duesseldorf. This study evaluated the resident satisfaction with the new concept.


  • Open Access

    Comparison of Two Different Scheimpflug Devices in the Detection of Keratoconus, Regular Astigmatism, and Healthy Corneas

    by David Finis, Bernhard Ralla, Maria Karbe, Maria Borrelli, Stefan Schrader, Gerd Geerling

    Aim. The aim of this study was to determine the intra- and interobserver variability of two Scheimpflug based camera systems, Pentacam and Sirius. In addition, the comparability of the measurements was tested in healthy subjects, subjects with regular astigmatism, and keratoconus patients.Methods. Intra- and interobserver variability were assessed in 20 healthy corneas. Pachymetry values were also compared with ultrasound pachymetry as a reference measurement. To detect possible differences between the two devices, 82 eyes with clinically established keratoconus, 30 eyes with regular astigmatism (>1.5 D), and 60 eyes without corneal pathologies were included in this prospective study.Results. Pachymetry and keratometry showed good intra- and interobserver variability for both devices. Pachymetry values obtained with the Sirius system (579±58 μm) were significantly higher compared to the Pentacam system (551±40 μm,P<0.001) and to ultrasound pachymetry (550±43 μm,P<0.001). Significant interdevice differences were found regarding the majority of the detected keratometry parameters.Conclusions. Both devices show almost perfect reproducibility in healthy subjects. However, pachymetry and keratometry values of the two devices should not be used interchangeably.


  • Vergleich des OSDI- und SPEED-Fragbogens zur Evaluation des Sicca-Syndroms in der klinischen Praxis

    by D. Finis, N. Pischel, C. König, J. Hayajneh, M. Borrelli, S. Schrader, G. Geerling


  • Evaluation of Lipid Layer Thickness Measurement of the Tear Film as a Diagnostic Tool for Meibomian Gland Dysfunction

    by David Finis, Nadja Pischel, Stefan Schrader, Gerd Geerling

    Purpose: The LipiView interferometer (TearScience Inc, Morrisville, NC) is capable of delivering quantitative values of the tear-film lipid layer thickness (LLT). The purpose of this study was to investigate whether there is a correlation between the LLT and other diagnostic criteria for Meibomian gland dysfunction (MGD). Methods: We performed a retrospective analysis of 110 patients (199 eyes) from our dry eye clinic. Subjective symptoms, break-up time (BUT), expressible Meibomian glands, and LLT were measured. Results: There was a significant correlation between expressible Meibomian glands and LLT (r = 0.36, P < 0.0001). Also, a possible trend of inverse correlation between subjective symptoms (standard patient evaluation of eye dryness) and the LLT was observed; however, this was not significant (r = −0.13, P < 0.08). Analysis of the whole study collective revealed no correlation between the BUT and the LLT (r = 0.003, P = 0.97). A subgroup analysis of the patients with an LLT ≤ 60 showed a better correlation between the LLT and the BUT, which was marginally not significant (r = 0.21; P = 0.059). For a cut-off value of ≤75-nm LLT, we found a sensitivity of 65.8% and a specificity of 63.4% for the detection of an MGD. For a cut-off value of ≤60, the sensitivity was 47.9%, and the specificity was 90.2%. Conclusions: The positive correlation between the LLT and expressible meibomian glands found in this study suggests a higher probability of MGD in patients with a low LLT. This automated assessment of the LLT might be a suitable screening test for detecting MGD. However, further prospective studies are needed to confirm these results and to identify potential confounders.


  • Epitheliale Dystrophien und Degenerationen der Hornhaut

    by D. Finis, J. Stammen, G. Geerling

    Lange Zeit wurden die Dystrophien der Hornhaut nach den Schichten beschrieben, in denen die morphologischen Auffälligkeiten mit der Spaltlampe oder dem Mikroskop in der Histologie und später dann auch elektronenmikroskopisch zu finden waren. Welche Zellen oder gar welche Gene für diese Veränderungen ausschlaggebend waren, wurde dabei allerdings außer Acht gelassen. Nachdem zunächst die eigentlich betroffenen Zellen genauer identifiziert werden konnten, sind heute auch ein Großteil der Gene sowie ein Teil der Mutationen bekannt, die die Dystrophien der Hornhaut hervorrufen. So weiß man heute, dass aufgrund der vergleichsweise hohen Teilungsrate und kurzen Lebensdauer der Epithelzellen der Hornhaut sehr viele Hornhautdystrophien von den Epithelzellen ausgehen, ohne dabei vorwiegend Trübungen oder Ablagerungen im Epithel hervorzurufen. Der Schwerpunkt dieses Beitrags liegt auf der Darstellung der epithelialen Dystrophien gemäß der Klassifikation des IC3D (International Committee for Classification of Corneal dystrophies) und ihrer Abgrenzung von den Degenerationen. Der Beitrag gibt zunächst einen allgemeinen Überblick über die Hornhautdystrophien und stellt die vor Kurzem erschienene internationale IC3D-Klassifikation vor. Im Anschluss werden einzelne Dystrophien und Beispiele von Degenerationen mit ihren Besonderheiten vorgestellt.

  • Epitheliale Dystrophien und Degenerationen der Hornhaut

    by D. Finis, J. Stammen, G. Geerling

    Lange Zeit wurden die Dystrophien der Hornhaut nach den Schichten beschrieben, in denen die morphologischen Auffälligkeiten mit der Spaltlampe oder dem Mikroskop in der Histologie und später dann auch elektronenmikroskopisch zu finden waren. Welche Zellen oder gar welche Gene für diese Veränderungen ausschlaggebend waren, wurde dabei allerdings außer Acht gelassen. Nachdem zunächst die eigentlich betroffenen Zellen genauer identifiziert werden konnten, sind heute auch ein Großteil der Gene sowie ein Teil der Mutationen bekannt, die die Dystrophien der Hornhaut hervorrufen. So weiß man heute, dass aufgrund der vergleichsweise hohen Teilungsrate und kurzen Lebensdauer der Epithelzellen der Hornhaut sehr viele Hornhautdystrophien von den Epithelzellen ausgehen, ohne dabei vorwiegend Trübungen oder Ablagerungen im Epithel hervorzurufen. Der Schwerpunkt dieses Beitrags liegt auf der Darstellung der epithelialen Dystrophien gemäß der Klassifikation des IC3D (International Committee for Classification of Corneal dystrophies) und ihrer Abgrenzung von den Degenerationen. Der Beitrag gibt zunächst einen allgemeinen Überblick über die Hornhautdystrophien und stellt die vor Kurzem erschienene internationale IC3D-Klassifikation vor. Im Anschluss werden einzelne Dystrophien und Beispiele von Degenerationen mit ihren Besonderheiten vorgestellt.