Adem Topcu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Adem Topcu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Asli Koktener
Department of Radiology, Fatih University School of Medicine, Emek, Turkey
2 shared publications - Dilek Kosehan
Department of Radiology, Turgut Özal University Faculty of Medicine, Ankara, Turkey
2 shared publications - Kayihan Akin
Department of Radiology, Fatih University School of Medicine, Emek, Turkey
2 shared publications Banu Cakir
Department of Radiology, Fatih University School of Medicine, Emek, Turkey
1 shared publication- Mehmet Teksam
Department of Radiology, Fatih University School of Medicine, Emek, Turkey
1 shared publication
Latest Publications
- 21 March 2013
- Published by Springer Nature in Emergency Radiology
- Vol. 20 (4) , 273-277
Spontaneous urinary extravasation: detection rate with 64-row multidetector computed tomography in patients presenting with acute abdomen
- 21 March 2013
- Published by Springer Nature in Emergency Radiology
- Vol. 20 (4) , 273-277
Spontaneous urinary extravasation: detection rate with 64-row multidetector computed tomography in patients presenting with acute abdomen
- 19 August 2010
- Published by Springer Nature in Skeletal Radiology
- Vol. 40 (4) , 447-452
Anatomic evaluation of the xiphoid process with 64-row multidetector computed tomography
Objective The aim of this study was to evaluate the interindividual variations of the xiphoid process in a wide adult group using 64-row multidetector computed tomography (MDCT). Materials and methods Included in the study were 500 consecutive patients who underwent coronary computed tomography angiography. Multiplanar reconstruction (MPR), maximum intensity projection (MIP) images on coronal and sagittal planes, and three-dimensional volume rendering (VR) reconstruction images were obtained and used for the evaluation of the anatomic features of the xiphoid process. Results The xiphoid process was present in all patients. The xiphoid process was deviated ventrally in 327 patients (65.4%). In 11 of these 327 patients (2.2%), ventral curving at the end of the xiphoid process resembled a hook. The xiphoid process was aligned in the same axis as the sternal corpus in 166 patients (33.2%). The tip of the xiphoid process was curved dorsally like a hook in three patients (0.6%). In four patients (0.8%), the xiphoid process exhibited a reverse S shape. Xiphoidal endings were single in 313 (62.6%) patients, double in 164 (32.8%), or triple in 23 (4.6%). Ossification of the cartilaginous xiphoid process was fully completed in 254 patients (50.8 %). In total, 171 patients (34.2%) had only one xiphoidal foramen and 45 patients (9%) had two or more foramina. Sternoxiphoidal fusion was present in 214 of the patients (42.8%). Conclusions Significant interindividual variations were detected in the xiphoid process. Excellent anatomic evaluation capacity of MDCT facilitates the detection of variations of the xiphoid process as well as the whole ribcage.
- 19 August 2010
- Published by Springer Nature in Skeletal Radiology
- Vol. 40 (4) , 447-452
Anatomic evaluation of the xiphoid process with 64-row multidetector computed tomography
Objective The aim of this study was to evaluate the interindividual variations of the xiphoid process in a wide adult group using 64-row multidetector computed tomography (MDCT). Materials and methods Included in the study were 500 consecutive patients who underwent coronary computed tomography angiography. Multiplanar reconstruction (MPR), maximum intensity projection (MIP) images on coronal and sagittal planes, and three-dimensional volume rendering (VR) reconstruction images were obtained and used for the evaluation of the anatomic features of the xiphoid process. Results The xiphoid process was present in all patients. The xiphoid process was deviated ventrally in 327 patients (65.4%). In 11 of these 327 patients (2.2%), ventral curving at the end of the xiphoid process resembled a hook. The xiphoid process was aligned in the same axis as the sternal corpus in 166 patients (33.2%). The tip of the xiphoid process was curved dorsally like a hook in three patients (0.6%). In four patients (0.8%), the xiphoid process exhibited a reverse S shape. Xiphoidal endings were single in 313 (62.6%) patients, double in 164 (32.8%), or triple in 23 (4.6%). Ossification of the cartilaginous xiphoid process was fully completed in 254 patients (50.8 %). In total, 171 patients (34.2%) had only one xiphoidal foramen and 45 patients (9%) had two or more foramina. Sternoxiphoidal fusion was present in 214 of the patients (42.8%). Conclusions Significant interindividual variations were detected in the xiphoid process. Excellent anatomic evaluation capacity of MDCT facilitates the detection of variations of the xiphoid process as well as the whole ribcage.