Karl-Juergen Halbhuber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Karl-Juergen Halbhuber has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Iris Riemann
3 shared publicationsBao-Gui Wang
Lasermicroscopy Research Unit, Department of Microscopic Anatomy (Anatomy II), Friedrich Schiller University, Jena, Germany
2 shared publicationsHarald Schubert
2 shared publicationsKarsten Koenig
Fraunhofer Institute of Biomedical Technology (IBMT)
2 shared publicationsAnnett Eitner
Lasermicroscopy Research Unit, Institute of Microscopic Anatomy (Anatomy II), Medical Faculty, Friedrich-Schiller University Jena, Teichgraben 7, 07743 Jena, Germany
1 shared publication- Bao-Gui Wang
Laser Microscopy Research Unit, Institute of Microscopic Anatomy, Faculty of Medicine, Friedrich Schiller University of Jena. Teichgraben 7, 07743 Jena, Germany
1 shared publication
Latest Publications
- 1 October 2008
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 24 (10) , 833-839
Multiphoton-mediated Corneal Flap Generation Using the 80 MHz Nanojoule Femtosecond Near-Infrared Laser
Purpose: To evaluate whether corneal flaps can be generated by the 80 MHz near-infrared, intense nanojoule femtosecond laser based on multiphoton absorption. Methods: A solid-state Ti:Sapphire femtosecond laser system was integrated in an inverted JenLab Femt-OCut laser scanning microscope. A diffraction-limited 40× objective was used to induce multiphoton ionization and plasma production. New Zealand albino rabbits and porcine eyes were used. Surgical outcomes were determined using frame and line scans with nanojoule pulses at a wavelength of 800 nm. Results: Surgical performance was assessed by optical imaging, histology, and electron microscopy. No significant corneal turbidity was observed. Optical imaging and histological examinations detected virtually no perturbation in the surrounding tissue. Corneal flaps and stromal lenticules were generated. Wound repair of the unlifted flaps was observed up to 90 days postoperatively. Conclusions: Surgical results and follow-up studies confirm that this femtosecond laser at nanojoule pulse energy is able to generate corneal flaps precisely, without causing visible collateral damage to the surrounding tissue or overlying epithelium. [ J Refract Surg . 2008;24:833–839.]
- 1 October 2008
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 24 (10) , 833-839
Multiphoton-mediated Corneal Flap Generation Using the 80 MHz Nanojoule Femtosecond Near-Infrared Laser
Purpose: To evaluate whether corneal flaps can be generated by the 80 MHz near-infrared, intense nanojoule femtosecond laser based on multiphoton absorption. Methods: A solid-state Ti:Sapphire femtosecond laser system was integrated in an inverted JenLab Femt-OCut laser scanning microscope. A diffraction-limited 40× objective was used to induce multiphoton ionization and plasma production. New Zealand albino rabbits and porcine eyes were used. Surgical outcomes were determined using frame and line scans with nanojoule pulses at a wavelength of 800 nm. Results: Surgical performance was assessed by optical imaging, histology, and electron microscopy. No significant corneal turbidity was observed. Optical imaging and histological examinations detected virtually no perturbation in the surrounding tissue. Corneal flaps and stromal lenticules were generated. Wound repair of the unlifted flaps was observed up to 90 days postoperatively. Conclusions: Surgical results and follow-up studies confirm that this femtosecond laser at nanojoule pulse energy is able to generate corneal flaps precisely, without causing visible collateral damage to the surrounding tissue or overlying epithelium. [ J Refract Surg . 2008;24:833–839.]
- 15 April 2008
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 40 (4) , 247-256
High‐resolution two‐photon excitation microscopy of ocular tissues in porcine eye
Background and Objective Two-photon excitation laser scanning microscopy (TPM), based on nonlinear optical (NLO) response under high irradiance, is currently being extensively employed for diagnostic purposes in biomedical fields and becomes more and more an interesting imaging technique in the intact bulk tissue examination. In this study, this nonlinear-excitation imaging technique including two-photon-mediated autofluorescence (2PF) and second harmonic generation (SHG) was employed to investigate the microstructures in the whole-mount scleral, retinal, and corneal tissues of porcine eyes with intracellular spatial resolution and high signal-to-noise ratio. Materials and Methods Image acquisition was based on the intense 80 MHz femtosecond (fs) near-infrared (NIR) laser pulses, emitted from a mode-locked solid-state titanium:sapphire system. By integrating a high-numerical aperture diffraction-limited objective, the whole-mount ocular specimens could be viewed from the surface of eye globes further to a 200 µm depth. Under high light irradiance at the order of MW-GW/cm2, more than one photon was simultaneously absorbed by endogenous molecules in ocular tissues. Results The cellular and fibrous components of whole-mount scleral and corneal tissues were selectively displayed in situ by in-tandem detection of 2PF and SHG with high efficiency without the assistance of any exogenous dye. NLO images of fibroblasts and mature elastic fibers in sclerae as well as of the retina radial Müller glial cells, ganglion cells, bipolar cells, photoreceptors, and retina pigment epithelial (RPE) cells were acquired with subcellular spatial resolution. In particular, the microstructural topography of cells and extracellular components in the whole-mount ocular tissues was elucidated in situ. Conclusion and Outlook The combination of the sensitive image acquisition technique allows to selectively studying of three-dimensional (3-D) architecture of cellular microstructures and extracellular matrix arrangement in situ at substantial depths in bulk tissues. The data obtained provided the primary knowledge for further studies of imaging entire eye globes based on two-photon excitation microscopy. Lesers Surg. Med. 40:247–256, 2008.
- 15 April 2008
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 40 (4) , 247-256
High‐resolution two‐photon excitation microscopy of ocular tissues in porcine eye
Background and Objective Two-photon excitation laser scanning microscopy (TPM), based on nonlinear optical (NLO) response under high irradiance, is currently being extensively employed for diagnostic purposes in biomedical fields and becomes more and more an interesting imaging technique in the intact bulk tissue examination. In this study, this nonlinear-excitation imaging technique including two-photon-mediated autofluorescence (2PF) and second harmonic generation (SHG) was employed to investigate the microstructures in the whole-mount scleral, retinal, and corneal tissues of porcine eyes with intracellular spatial resolution and high signal-to-noise ratio. Materials and Methods Image acquisition was based on the intense 80 MHz femtosecond (fs) near-infrared (NIR) laser pulses, emitted from a mode-locked solid-state titanium:sapphire system. By integrating a high-numerical aperture diffraction-limited objective, the whole-mount ocular specimens could be viewed from the surface of eye globes further to a 200 µm depth. Under high light irradiance at the order of MW-GW/cm2, more than one photon was simultaneously absorbed by endogenous molecules in ocular tissues. Results The cellular and fibrous components of whole-mount scleral and corneal tissues were selectively displayed in situ by in-tandem detection of 2PF and SHG with high efficiency without the assistance of any exogenous dye. NLO images of fibroblasts and mature elastic fibers in sclerae as well as of the retina radial Müller glial cells, ganglion cells, bipolar cells, photoreceptors, and retina pigment epithelial (RPE) cells were acquired with subcellular spatial resolution. In particular, the microstructural topography of cells and extracellular components in the whole-mount ocular tissues was elucidated in situ. Conclusion and Outlook The combination of the sensitive image acquisition technique allows to selectively studying of three-dimensional (3-D) architecture of cellular microstructures and extracellular matrix arrangement in situ at substantial depths in bulk tissues. The data obtained provided the primary knowledge for further studies of imaging entire eye globes based on two-photon excitation microscopy. Lesers Surg. Med. 40:247–256, 2008.
- 20 July 2007
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 39 (6) , 527-533
Multiphoton microscopy for monitoring intratissue femtosecond laser surgery effects
Background and Objective: Multiphoton microscopy/tomography has been used as a novel diagnostic method for corneal imaging with subcellular resolution. Here, we used this technique to monitor femtosecond laser intratissue surgery effects.Materials and Methods: Multiphoton microscopy/tomography on rabbits based on intense 90 MHz femtosecond Ti: sapphire laser was realized at intensities of MW‐GW/cm2, whereas the surgical procedures were performed with the same system at a higher light intensity on the order of TW/cm2.Results: Multiphoton microscopy/tomography proved capable of determining the target of interest, and of visualizing and optically evaluating the in vivo intrastromal laser surgical outcomes with high efficiency. More interesting, using this technique, activated intrastromal keratocytes (myofibroblasts) were detected in vivo 24 hours after intrastromal surgery.Conclusion: Multiphoton microscopy/tomography is an efficient and convenient non‐invasive imaging method which can be used not only to assess intrastromal microsurgical performance but also to perform in vivo follow‐up observations on wound repair. Lasers Surg. Med. 39:527–533, 2007.
- 20 July 2007
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 39 (6) , 527-533
Multiphoton microscopy for monitoring intratissue femtosecond laser surgery effects
Background and Objective: Multiphoton microscopy/tomography has been used as a novel diagnostic method for corneal imaging with subcellular resolution. Here, we used this technique to monitor femtosecond laser intratissue surgery effects.Materials and Methods: Multiphoton microscopy/tomography on rabbits based on intense 90 MHz femtosecond Ti: sapphire laser was realized at intensities of MW‐GW/cm2, whereas the surgical procedures were performed with the same system at a higher light intensity on the order of TW/cm2.Results: Multiphoton microscopy/tomography proved capable of determining the target of interest, and of visualizing and optically evaluating the in vivo intrastromal laser surgical outcomes with high efficiency. More interesting, using this technique, activated intrastromal keratocytes (myofibroblasts) were detected in vivo 24 hours after intrastromal surgery.Conclusion: Multiphoton microscopy/tomography is an efficient and convenient non‐invasive imaging method which can be used not only to assess intrastromal microsurgical performance but also to perform in vivo follow‐up observations on wound repair. Lasers Surg. Med. 39:527–533, 2007.
- 4 May 2006
- Published by Springer Nature in Histochemistry and Cell Biology
- Vol. 126 (4) , 507-515
Intraocular multiphoton microscopy with subcellular spatial resolution by infrared femtosecond lasers
We reported on the in situ nonlinear optical sectioning of the corneal and retinal tissues based on the multiphoton microscopy (MPM) with different excitation wavelengths of infrared femtosecond (fs) lasers. The multiphoton nonlinear processing including two-photon fluorescence (2PF) and second harmonic generation (SHG) was induced under condition of high light intensities on an order of MW-GW/cm2. The laser beams emitted from the solid-state Ti: sapphire systems were focused in a 0.1 femtoliter focus volume of a high numerous aperture diffraction-limited objective (40 × 1.3 N.A., oil). The corneal layers have been visualized using nonlinear optical tomography. In particular, corneal Bowman’s layer was optically determined in situ. The cellular and collagen components of tissues were selectively displayed with submicron spatial resolution and high efficiency without any assistance of staining or slicing. The preliminary study on retinal optical tomography is here also reported. MPM is a promising and convenient non-invasive technique by which the tissue layers can be visualized and the selective displaying of the tissue microstructures be realized. The optical biopsy based on intrinsic emission of MPM yields details that provide three-dimensional displaying of the tissue component and even have the potential to be used in clinical diagnostics.
- 4 May 2006
- Published by Springer Nature in Histochemistry and Cell Biology
- Vol. 126 (4) , 507-515
Intraocular multiphoton microscopy with subcellular spatial resolution by infrared femtosecond lasers
We reported on the in situ nonlinear optical sectioning of the corneal and retinal tissues based on the multiphoton microscopy (MPM) with different excitation wavelengths of infrared femtosecond (fs) lasers. The multiphoton nonlinear processing including two-photon fluorescence (2PF) and second harmonic generation (SHG) was induced under condition of high light intensities on an order of MW-GW/cm2. The laser beams emitted from the solid-state Ti: sapphire systems were focused in a 0.1 femtoliter focus volume of a high numerous aperture diffraction-limited objective (40 × 1.3 N.A., oil). The corneal layers have been visualized using nonlinear optical tomography. In particular, corneal Bowman’s layer was optically determined in situ. The cellular and collagen components of tissues were selectively displayed with submicron spatial resolution and high efficiency without any assistance of staining or slicing. The preliminary study on retinal optical tomography is here also reported. MPM is a promising and convenient non-invasive technique by which the tissue layers can be visualized and the selective displaying of the tissue microstructures be realized. The optical biopsy based on intrinsic emission of MPM yields details that provide three-dimensional displaying of the tissue component and even have the potential to be used in clinical diagnostics.
- 23 May 1997
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2983, 37-45
Cell damage in UVA and cw/femtosecond NIR microscopes
Cell damage in UV and NIR laser microscopes by highly focused micromanipulation and fluorescence excitation microbeams has been studied. Damage in erythrocytes, spermatozoa and Chinese hamster ovary cells was detected by monitoring morphology changes, autofluorescence detection, cloning assay, and viability screening. It was found that 364 nm/365 nm UVA radiation induced irreversible cell damage at radiant exposures as low as 2. NIR CW microradiation used in laser tweezers was also able to damage cells via a two-photon excitation process, in particular, when using <800 nm trapping beams. Non- destructive two-photon excitation in femtosecond NIR microscopes is possible within a narrow intensity window. The lower limit is determined by two-photon absorption coefficients and detector efficiency, the higher by intracellular optical breakdown in the extranuclear region. Above certain wavelength-dependent intensity thresholds in femtosecond microscopy, cells were completely destroyed by fragmentation concomitant with plasma generation. The influence of excitation and micromanipulation microbeams should be considered when studying physiology and metabolism of vital cells.
- 23 May 1997
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2983, 37-45
Cell damage in UVA and cw/femtosecond NIR microscopes
Cell damage in UV and NIR laser microscopes by highly focused micromanipulation and fluorescence excitation microbeams has been studied. Damage in erythrocytes, spermatozoa and Chinese hamster ovary cells was detected by monitoring morphology changes, autofluorescence detection, cloning assay, and viability screening. It was found that 364 nm/365 nm UVA radiation induced irreversible cell damage at radiant exposures as low as 2. NIR CW microradiation used in laser tweezers was also able to damage cells via a two-photon excitation process, in particular, when using <800 nm trapping beams. Non- destructive two-photon excitation in femtosecond NIR microscopes is possible within a narrow intensity window. The lower limit is determined by two-photon absorption coefficients and detector efficiency, the higher by intracellular optical breakdown in the extranuclear region. Above certain wavelength-dependent intensity thresholds in femtosecond microscopy, cells were completely destroyed by fragmentation concomitant with plasma generation. The influence of excitation and micromanipulation microbeams should be considered when studying physiology and metabolism of vital cells.