Bijia Shi
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bijia Shi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Peter D. Larsen
Department of Surgery and Anaesthesia, University of Otago, Wellington, New Zealand
2 shared publications Alejandro Jimenez
Wellington Cardiovascular Research Group , Wellington 6021 , New Zealand 3 Department of Cardiology , Wellington Regional Hospital , Wellington 6021 , New Zealand
1 shared publication- Alexander Sasse
University of Washington, Universitat Heidelberg
1 shared publication Katherine A. Ferrier
Wellington Cardiovascular Research Group, Wellington, New Zealand; Cardiology Department, Hutt Hospital, Wellington, New Zealand
1 shared publicationPeter Larsen
Wellington Cardiovascular Research Group, Wellington, New Zealand
1 shared publicationScott A. Harding
Wellington Cardiovascular Research Group , Wellington 6021 , New Zealand 3 Department of Cardiology , Wellington Regional Hospital , Wellington 6021 , New Zealand
1 shared publication
Latest Publications
- 13 June 2016
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 22 (2) , e12390
Analysis of ECG Measures of Cardiac Repolarization in Relation to Arrhythmic Events in an Implantable Cardioverter Defibrillator Population
ECG-derived measures of cardiac repolarization may have utility in risk prediction of future ventricular arrhythmia, and a range of different measures have been proposed. We compared time-based, vectorcardiographic, and singular value decomposition (SVD) derived measures of repolarization to determine which was most predictive of appropriate therapy in an ICD population. We examined the independent prognostic value of a range of repolarization measures derived from 60 second 12-lead ECG recordings in 150 patients receiving new ICD implants in relation to the occurrence of appropriate therapy during follow-up. Over an average follow-up of 2.15 ± 0.87 years, male gender, presence of premature ventricular complex (PVC), relative T wave residuum (TWR-rel, measures regional repolarization heterogeneity), and TCRT (the total cosine R-to-T, describes the global angle between repolarization and depolarization wavefronts) were the only independent predictors of appropriate therapy. With every 0.01% increase in TWR-rel, there was 2% increased risk of appropriate therapy (HR = 1.02, 95% CI 1.006-1.034, P < 0.001). With every 1° decrease in TCRT, there was an increase in arrhythmic risk of 0.9% (HR 1.009, 95% CI 1.003-1.015, P = 0.003). The use of advanced analytic ECG techniques to derive measures of repolarization abnormality might shave utility in risk stratification in an ICD population.
- 13 June 2016
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 22 (2) , e12390
Analysis of ECG Measures of Cardiac Repolarization in Relation to Arrhythmic Events in an Implantable Cardioverter Defibrillator Population
ECG-derived measures of cardiac repolarization may have utility in risk prediction of future ventricular arrhythmia, and a range of different measures have been proposed. We compared time-based, vectorcardiographic, and singular value decomposition (SVD) derived measures of repolarization to determine which was most predictive of appropriate therapy in an ICD population. We examined the independent prognostic value of a range of repolarization measures derived from 60 second 12-lead ECG recordings in 150 patients receiving new ICD implants in relation to the occurrence of appropriate therapy during follow-up. Over an average follow-up of 2.15 ± 0.87 years, male gender, presence of premature ventricular complex (PVC), relative T wave residuum (TWR-rel, measures regional repolarization heterogeneity), and TCRT (the total cosine R-to-T, describes the global angle between repolarization and depolarization wavefronts) were the only independent predictors of appropriate therapy. With every 0.01% increase in TWR-rel, there was 2% increased risk of appropriate therapy (HR = 1.02, 95% CI 1.006-1.034, P < 0.001). With every 1° decrease in TCRT, there was an increase in arrhythmic risk of 0.9% (HR 1.009, 95% CI 1.003-1.015, P = 0.003). The use of advanced analytic ECG techniques to derive measures of repolarization abnormality might shave utility in risk stratification in an ICD population.
- 1 January 2014
- Published by Elsevier in Journal of Electrocardiology
- Vol. 47 (1) , 52-58
Correlation between vectorcardiographic measures and cardiac magnetic resonance imaging of the left ventricle in an implantable cardioverter defibrillator population
- 1 January 2014
- Published by Elsevier in Journal of Electrocardiology
- Vol. 47 (1) , 52-58
Correlation between vectorcardiographic measures and cardiac magnetic resonance imaging of the left ventricle in an implantable cardioverter defibrillator population
- Open Access
- 1 November 2012
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 15 (6) , 892-898
Standard 12-lead electrocardiography measures predictive of increased appropriate therapy in implantable cardioverter defibrillator recipients
Identification of patients most likely to benefit from implantable cardioverter defibrillator (ICD) implant remains a complex challenge. This study aimed to investigate the utility of measures derived from standard 10 s 12-lead electrocardiogrphy (ECG) without complex signal processing in predicting appropriate therapy in an ICD population. We examined 108 ICD patients for primary (n = 32) and secondary prevention (n = 76). Baseline clinical data and characteristics of QRS complex, T-wave, and heart rate from standard 12-lead ECG were examined and related to the occurrence of subsequent appropriate therapy. Over a mean follow-up of 29 ± 11 months, 44% of patients received appropriate therapy. Patients with depressed heart rate variability (HRV) (≤6.5%) were 2.68 [95% confidence interval (CI) 1.21–5.90, P = 0.015] times more likely to receive appropriate therapy than patients with HRV >6.5%. In patients with bundle branch block (BBB), large QRS dispersion of >39 ms was associated with 2.88 times risk (95% CI 1.24–6.71, P = 0.014) of experiencing appropriate therapy than those with QRS dispersion P = 0.005] and secondary prevention (HR = 2.55, 95% CI 1.14–5.71, P = 0.022) were also predictive of device therapy. Measurements from standard 12-lead ECG were predictive of appropriate therapy in a heterogeneous ICD population. Incorporation of 12-lead ECG parameters such as these into risk stratification models may improve our ability to select patients for ICD implantation.
- 1 November 2012
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 15 (6) , 892-898
Open AccessStandard 12-lead electrocardiography measures predictive of increased appropriate therapy in implantable cardioverter defibrillator recipients
Identification of patients most likely to benefit from implantable cardioverter defibrillator (ICD) implant remains a complex challenge. This study aimed to investigate the utility of measures derived from standard 10 s 12-lead electrocardiogrphy (ECG) without complex signal processing in predicting appropriate therapy in an ICD population. We examined 108 ICD patients for primary (n = 32) and secondary prevention (n = 76). Baseline clinical data and characteristics of QRS complex, T-wave, and heart rate from standard 12-lead ECG were examined and related to the occurrence of subsequent appropriate therapy. Over a mean follow-up of 29 ± 11 months, 44% of patients received appropriate therapy. Patients with depressed heart rate variability (HRV) (≤6.5%) were 2.68 [95% confidence interval (CI) 1.21–5.90, P = 0.015] times more likely to receive appropriate therapy than patients with HRV >6.5%. In patients with bundle branch block (BBB), large QRS dispersion of >39 ms was associated with 2.88 times risk (95% CI 1.24–6.71, P = 0.014) of experiencing appropriate therapy than those with QRS dispersion P = 0.005] and secondary prevention (HR = 2.55, 95% CI 1.14–5.71, P = 0.022) were also predictive of device therapy. Measurements from standard 12-lead ECG were predictive of appropriate therapy in a heterogeneous ICD population. Incorporation of 12-lead ECG parameters such as these into risk stratification models may improve our ability to select patients for ICD implantation.