BSBijia Shi

Bijia Shi

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bijia Shi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Peter D. Larsen

    Department of Surgery and Anaesthesia, University of Otago, Wellington, New Zealand

    2 shared publications
  • Alejandro Jimenez

    Wellington Cardiovascular Research Group , Wellington 6021 , New Zealand 3 Department of Cardiology , Wellington Regional Hospital , Wellington 6021 , New Zealand

    1 shared publication
  • Alexander Sasse

    University of Washington, Universitat Heidelberg

    1 shared publication
  • Katherine A. Ferrier

    Wellington Cardiovascular Research Group, Wellington, New Zealand; Cardiology Department, Hutt Hospital, Wellington, New Zealand

    1 shared publication
  • Peter Larsen

    Wellington Cardiovascular Research Group, Wellington, New Zealand

    1 shared publication
  • Scott A. Harding

    Wellington Cardiovascular Research Group , Wellington 6021 , New Zealand 3 Department of Cardiology , Wellington Regional Hospital , Wellington 6021 , New Zealand

    1 shared publication

Latest Publications

  • Analysis of ECG Measures of Cardiac Repolarization in Relation to Arrhythmic Events in an Implantable Cardioverter Defibrillator Population

    by Bijia Shi, Scott Harding, Peter Larsen

    ECG-derived measures of cardiac repolarization may have utility in risk prediction of future ventricular arrhythmia, and a range of different measures have been proposed. We compared time-based, vectorcardiographic, and singular value decomposition (SVD) derived measures of repolarization to determine which was most predictive of appropriate therapy in an ICD population. We examined the independent prognostic value of a range of repolarization measures derived from 60 second 12-lead ECG recordings in 150 patients receiving new ICD implants in relation to the occurrence of appropriate therapy during follow-up. Over an average follow-up of 2.15 ± 0.87 years, male gender, presence of premature ventricular complex (PVC), relative T wave residuum (TWR-rel, measures regional repolarization heterogeneity), and TCRT (the total cosine R-to-T, describes the global angle between repolarization and depolarization wavefronts) were the only independent predictors of appropriate therapy. With every 0.01% increase in TWR-rel, there was 2% increased risk of appropriate therapy (HR = 1.02, 95% CI 1.006-1.034, P < 0.001). With every 1° decrease in TCRT, there was an increase in arrhythmic risk of 0.9% (HR 1.009, 95% CI 1.003-1.015, P = 0.003). The use of advanced analytic ECG techniques to derive measures of repolarization abnormality might shave utility in risk stratification in an ICD population.


  • Open Access

    Standard 12-lead electrocardiography measures predictive of increased appropriate therapy in implantable cardioverter defibrillator recipients

    by Bijia Shi, Scott A. Harding, Alejandro Jimenez, Peter D. Larsen

    Identification of patients most likely to benefit from implantable cardioverter defibrillator (ICD) implant remains a complex challenge. This study aimed to investigate the utility of measures derived from standard 10 s 12-lead electrocardiogrphy (ECG) without complex signal processing in predicting appropriate therapy in an ICD population. We examined 108 ICD patients for primary (n = 32) and secondary prevention (n = 76). Baseline clinical data and characteristics of QRS complex, T-wave, and heart rate from standard 12-lead ECG were examined and related to the occurrence of subsequent appropriate therapy. Over a mean follow-up of 29 ± 11 months, 44% of patients received appropriate therapy. Patients with depressed heart rate variability (HRV) (≤6.5%) were 2.68 [95% confidence interval (CI) 1.21–5.90, P = 0.015] times more likely to receive appropriate therapy than patients with HRV >6.5%. In patients with bundle branch block (BBB), large QRS dispersion of >39 ms was associated with 2.88 times risk (95% CI 1.24–6.71, P = 0.014) of experiencing appropriate therapy than those with QRS dispersion P = 0.005] and secondary prevention (HR = 2.55, 95% CI 1.14–5.71, P = 0.022) were also predictive of device therapy. Measurements from standard 12-lead ECG were predictive of appropriate therapy in a heterogeneous ICD population. Incorporation of 12-lead ECG parameters such as these into risk stratification models may improve our ability to select patients for ICD implantation.