Monsey McLeod
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Monsey McLeod has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Bryony Dean Franklin
Director, Centre for Medication Safety and Service Quality, Imperial College Healthcare NHS Trust, London, UK
3 shared publications Agnieszka Zochowska
Department of Pharmacy, Medical University of Warsaw, Warsaw, Poland
1 shared publicationAnn Jacklin
Department of Pharmacy, Imperial College Healthcare NHS Trust, London, UK
1 shared publicationDavid Leonard
Department of Pharmacy, Imperial College Healthcare NHS Trust, London, UK
1 shared publicationMarian Crow
Department of Pharmacy, Imperial College Healthcare NHS Trust, London, UK
1 shared publicationNick Barber
Centre for Medication Safety and Service Quality, UCL School of Pharmacy and Imperial College Healthcare NHS Trust, London, UK
1 shared publication
Latest Publications
- Open Access
- 27 February 2014
- Published by Springer Nature in BMC Health Services Research
- Vol. 14 (1) , 93
A national survey of inpatient medication systems in English NHS hospitals
Systems and processes for prescribing, supplying and administering inpatient medications can have substantial impact on medication administration errors (MAEs). However, little is known about the medication systems and processes currently used within the English National Health Service (NHS). This presents a challenge for developing NHS-wide interventions to increase medication safety. We therefore conducted a cross-sectional postal census of medication systems and processes in English NHS hospitals to address this knowledge gap.
- 27 February 2014
- Published by Springer Nature in BMC Health Services Research
- Vol. 14 (1) , 93
Open AccessA national survey of inpatient medication systems in English NHS hospitals
Systems and processes for prescribing, supplying and administering inpatient medications can have substantial impact on medication administration errors (MAEs). However, little is known about the medication systems and processes currently used within the English National Health Service (NHS). This presents a challenge for developing NHS-wide interventions to increase medication safety. We therefore conducted a cross-sectional postal census of medication systems and processes in English NHS hospitals to address this knowledge gap.
- 15 January 2013
- Published by BMJ in BMJ Quality & Safety
- Vol. 22 (4) , 278-289
Methodological variations and their effects on reported medication administration error rates
Background Medication administration errors (MAEs) are a problem, yet methodological variation between studies presents a potential barrier to understanding how best to increase safety. Using the UK as a case-study, we systematically summarised methodological variations in MAE studies, and their effects on reported MAE rates. Methods Nine healthcare databases were searched for quantitative observational MAE studies in UK hospitals. Methodological variations were analysed and meta-analysis of MAE rates performed using studies that used the same definitions. Odds ratios (OR) were calculated to compare MAE rates between intravenous (IV) and non-IV doses, and between paediatric and adult doses. Results We identified 16 unique studies reporting three MAE definitions, 44 MAE subcategories and four different denominators. Overall adult MAE rates were 5.6% of a total of 21 533 non-IV opportunities for error (OE) (95% CI 4.6% to 6.7%) and 35% of a total of 154 IV OEs (95% CI 2% to 68%). MAEs were five times more likely in IV than non-IV doses (pooled OR 5.1; 95% CI 3.5 to 7.5). Including timing errors of ±30 min increased the MAE rate from 27% to 69% of 320 IV doses in one study. Five studies were unclear as to whether the denominator included dose omissions; omissions accounted for 0%–13% of IV doses and 1.8%–5.1% of non-IV doses. Conclusions Wide methodological variations exist even within one country, some with significant effects on reported MAE rates. We have made recommendations for future MAE studies; these may be applied both within and outside the UK.
- 15 January 2013
- Published by BMJ in BMJ Quality & Safety
- Vol. 22 (4) , 278-289
Methodological variations and their effects on reported medication administration error rates
Background Medication administration errors (MAEs) are a problem, yet methodological variation between studies presents a potential barrier to understanding how best to increase safety. Using the UK as a case-study, we systematically summarised methodological variations in MAE studies, and their effects on reported MAE rates. Methods Nine healthcare databases were searched for quantitative observational MAE studies in UK hospitals. Methodological variations were analysed and meta-analysis of MAE rates performed using studies that used the same definitions. Odds ratios (OR) were calculated to compare MAE rates between intravenous (IV) and non-IV doses, and between paediatric and adult doses. Results We identified 16 unique studies reporting three MAE definitions, 44 MAE subcategories and four different denominators. Overall adult MAE rates were 5.6% of a total of 21 533 non-IV opportunities for error (OE) (95% CI 4.6% to 6.7%) and 35% of a total of 154 IV OEs (95% CI 2% to 68%). MAEs were five times more likely in IV than non-IV doses (pooled OR 5.1; 95% CI 3.5 to 7.5). Including timing errors of ±30 min increased the MAE rate from 27% to 69% of 320 IV doses in one study. Five studies were unclear as to whether the denominator included dose omissions; omissions accounted for 0%–13% of IV doses and 1.8%–5.1% of non-IV doses. Conclusions Wide methodological variations exist even within one country, some with significant effects on reported MAE rates. We have made recommendations for future MAE studies; these may be applied both within and outside the UK.
- 19 April 2012
- Published by BMJ in European Journal of Hospital Pharmacy
- Vol. 19 (3) , 293-298
Comparing the upper limb disorder risks associated with manual and automated cytotoxic compounding: a pilot study
Objectives To conduct a pilot study to compare the upper limb disorder (ULD) risk associated with manual and automated cytotoxic compounding, and comment on the suitability of using the UK Health and Safety Executive Assessment of Repetitive Tasks (ART) tool for this purpose. Methods The ART tool comprised 12 domains, each scored on an ordinal scale. An overall ULD exposure score was calculated and categorised using the tool as low, medium or high risk. 21 manual and four automated sessions were observed in a UK hospital pharmacy aseptic unit; a smaller sample of automated sessions were used as these showed little variation in exposure score. The following were compared: (1) median (IQR) overall exposure scores; (2) overall exposure level categories; and (3) median (IQR) risk scores for each of the 12 domains. Practicalities of using the ART tool were documented. Results Manual sessions were associated with a higher median ULD exposure score (9.8 (IQR 8.8 to 12.0)) than automation (1.0 (0.9 to 1.3)). 14 manual sessions were low risk and seven were medium risk. All automated sessions were low risk. Overall, eight domains scored higher in the manual sessions than automated session; four domains scored the same. The largest difference in median exposure score was for domains regarding ‘force’, ‘arm movement’ and ‘arm posture’. Conclusions Automated compounding was associated with a lower ULD exposure score than manual compounding in our aseptic unit. The ART tool was useful for comparing ULD risk of manual and automated cytotoxic compounding.
- 19 April 2012
- Published by BMJ in European Journal of Hospital Pharmacy
- Vol. 19 (3) , 293-298
Comparing the upper limb disorder risks associated with manual and automated cytotoxic compounding: a pilot study
Objectives To conduct a pilot study to compare the upper limb disorder (ULD) risk associated with manual and automated cytotoxic compounding, and comment on the suitability of using the UK Health and Safety Executive Assessment of Repetitive Tasks (ART) tool for this purpose. Methods The ART tool comprised 12 domains, each scored on an ordinal scale. An overall ULD exposure score was calculated and categorised using the tool as low, medium or high risk. 21 manual and four automated sessions were observed in a UK hospital pharmacy aseptic unit; a smaller sample of automated sessions were used as these showed little variation in exposure score. The following were compared: (1) median (IQR) overall exposure scores; (2) overall exposure level categories; and (3) median (IQR) risk scores for each of the 12 domains. Practicalities of using the ART tool were documented. Results Manual sessions were associated with a higher median ULD exposure score (9.8 (IQR 8.8 to 12.0)) than automation (1.0 (0.9 to 1.3)). 14 manual sessions were low risk and seven were medium risk. All automated sessions were low risk. Overall, eight domains scored higher in the manual sessions than automated session; four domains scored the same. The largest difference in median exposure score was for domains regarding ‘force’, ‘arm movement’ and ‘arm posture’. Conclusions Automated compounding was associated with a lower ULD exposure score than manual compounding in our aseptic unit. The ART tool was useful for comparing ULD risk of manual and automated cytotoxic compounding.