Dipan Bose
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dipan Bose has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Carlos Arregui-Dalmases
2 shared publications- Jeff R. Crandall
Center for Applied Biomechanics, University of Virginia, Charlottesville, VA, USA
2 shared publications - Aaron Forbes
School of Medicine, University of North Carolina, Chapel Hill, NC, USA
1 shared publication - Damien Subit
B Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech , Paris , France
1 shared publication David Sanchez-Molina
1 shared publicationEduardo Del Pozo
1 shared publication
Latest Publications
- 1 October 2015
- Published by Elsevier in Accident Analysis & Prevention
- Vol. 83, 37-46
Analysis of crash parameters and driver characteristics associated with lower limb injury
- 1 October 2015
- Published by Elsevier in Accident Analysis & Prevention
- Vol. 83, 37-46
Analysis of crash parameters and driver characteristics associated with lower limb injury
- 1 July 2015
- Published by Elsevier in Accident Analysis & Prevention
- Vol. 80, 7-17
The tolerance of the human body to automobile collision impact – a systematic review of injury biomechanics research, 1990–2009
- 1 July 2015
- Published by Elsevier in Accident Analysis & Prevention
- Vol. 80, 7-17
The tolerance of the human body to automobile collision impact – a systematic review of injury biomechanics research, 1990–2009
- 1 April 2013
- Published by Elsevier in Accident Analysis & Prevention
- Vol. 53, 100-104
Increased risk of driver fatality due to unrestrained rear-seat passengers in severe frontal crashes
- 1 April 2013
- Published by Elsevier in Accident Analysis & Prevention
- Vol. 53, 100-104
Increased risk of driver fatality due to unrestrained rear-seat passengers in severe frontal crashes
- 1 January 2010
- Vol. 46, 440-5
Response of the sternum under dynamic 3-point bending - biomed 2010.
The goal of this study was to investigate the response and failure properties of the human sternum under bending loading. Nine sternum specimens from post mortem human surrogates (n=7 male, n=2 female, age: 62.7 +/- 10.9 years) were extracted and potted in a three point bending test setup. Specimens were loaded to failure at their center points in bending at 1100 mm/s, with some specimens previously loaded in a non-failure quasi-static loading test. In two cases, the non-failure test was repeated to show that specimens were not damaged during non-failure testing. The sternum specimens were found generally to be unable to support shear forces in the anterior-posterior direction and as a result had relatively low failure moments (24.1 Nm +/- 20.1 Nm). While two of the specimens did fail in bending, the remaining specimens failed as a result of the high tensile forces introduced by the bending loads. These specimens first experienced compressive loads, and then, as the potted ends continued to rotate, tensile loads, which resulted in failure of the specimens (400-800 N).
- 1 January 2010
- Vol. 46, 440-5
Response of the sternum under dynamic 3-point bending - biomed 2010.
The goal of this study was to investigate the response and failure properties of the human sternum under bending loading. Nine sternum specimens from post mortem human surrogates (n=7 male, n=2 female, age: 62.7 +/- 10.9 years) were extracted and potted in a three point bending test setup. Specimens were loaded to failure at their center points in bending at 1100 mm/s, with some specimens previously loaded in a non-failure quasi-static loading test. In two cases, the non-failure test was repeated to show that specimens were not damaged during non-failure testing. The sternum specimens were found generally to be unable to support shear forces in the anterior-posterior direction and as a result had relatively low failure moments (24.1 Nm +/- 20.1 Nm). While two of the specimens did fail in bending, the remaining specimens failed as a result of the high tensile forces introduced by the bending loads. These specimens first experienced compressive loads, and then, as the potted ends continued to rotate, tensile loads, which resulted in failure of the specimens (400-800 N).