HOHidetoshi Oguro

Hidetoshi Oguro

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hidetoshi Oguro has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Performance of a 14-T CuNb/Nb3Sn Rutherford coil with a 300 mm wide cold bore

    by Hidetoshi Oguro, Kazuo Watanabe, Satoshi Awaji, Satoshi Hanai, Shigeru Ioka, Masahiro Sugimoto, Hirokazu Tsubouchi

    A large-bore 14-T CuNb/Nb 3 Sn Rutherford coil was developed for a 25 T cryogen-free superconducting magnet. The magnet consisted of a low-temperature superconducting (LTS) magnet of NbTi and Nb 3 Sn Rutherford coils, and a high-temperature superconducting magnet. The Nb 3 Sn Rutherford coil was fabricated by the react-and-wind method for the first time. The LTS magnet reached the designed operation current of 854 A without a training quench at a 1 h ramp rate. The central magnetic field generated by the LTS magnet was measured by a Hall sensor to be 14.0 T at 854 A in a 300 mm cold bore.


  • Transport Properties of CuNb/Nb3Sn Rutherford Coils With Various Diameters

    by H. Oguro, S. Awaji, K. Watanabe, T. Omura, X. Chaud, Y. Miyoshi, S. Nimori, T. Shimizu, M. Sugimoto, H. Tsubouchi, et al.

    Our group has been developing an Nb-rod-processed CuNb-reinforced Nb3Sn Rutherford cable for developments in high-field superconducting magnets, such as a 25-T cryogen-free superconducting magnet. The Rutherford cable has good mechanical, electrical, and superconducting properties in high fields. In this paper, we investigated the influence of winding coil diameters on the transport properties of the Rutherford cable for the coil application wound with a react-and-wind method. We prepared two Rutherford coils with diameters of 110 mm (0.2% pure bending strain) and 70 mm (0.6% pure bending strain) with 0.7% prebending treatment in order to measure the critical current at various temperatures in fields up to 18 T. We found that the Rutherford coil with a diameter of 110 mm has good transport properties. The critical current of the Rutherford coil with a diameter of 70 mm exhibited a deterioration of about 14% in comparison to the coil having a diameter of 110 mm. Although the tensile strain dependence of the critical current (Ic) suggests a large deterioration for the 0.6% pure bent coil, the Rutherford coil can keep the high Ic under a large pure bending strain.


  • Improvement of a Large Bore Cryogen-Free Superconducting Magnet for a Hybrid Magnet

    by T. Tsurudome, Y. Mikami, A. Hashimoto, H. Mitsubori, H. Ookubo, J. Sakuraba, T. Kato, K. Watazawa, K. Watanabe, S. Awaji, et al.

    A 360-mm room-temperature bore cryogen-free superconducting magnet (CSM), consisting of Nb 3Sn coils and NbTi coils, for a hybrid magnet (HM) has generated the maximum magnetic field of 9.5 T. However, the magnetic field of the CSM has been limited to 8.5 T in the hybrid magnet mode because of a cooling problem. As a result, the hybrid magnet composed of a 19-T water-cooled resistive magnet (WM) had the utmost field generation of 27.5 T. Therefore, we improved the CSM to generate higher magnetic fields. For the improvement of the cooling problem, Nb 3Sn coils were replaced, and thermal conduction was improved between coils and a 4K-GM cryocooler. Furthermore, support structures with a tensile strength over 80 kN and a spring support were adopted against the magnetic force to support the self-weight of coils and to absorb stress caused by thermal contraction difference between each coil. After the improvement, the CSM generated 9.5 T within 1 h and the maximum magnetic field of 9.7 T in a 360-mm room-temperature bore. The HM succeeded in generating 28 T in a 32-mm room-temperature bore with the CSM operated at 9.0 T.


  • Transport Properties of CuNb Reinforced $\hbox{Nb}_{3}\hbox{Sn}$ Rutherford Coils in High Fields

    by H. Oguro, T. Omura, S. Awaji, K. Watanabe, S. Nimori, T. Shimizu, M. Sugimoto, H. Tsubouchi, S. Hanai

    Nb 3 Sn Rutherford cables have been investigated for the development of a 25-T cryogen-free superconducting magnet. We developed Rutherford cables composed of 16 Nb-rodprocessed CuNb-reinforced Nb 3 Sn (CuNb/Nb 3 Sn) strands with an 0.8-mm diameter. In this paper, the transport and mechanical properties of the epoxy impregnated multilayer coil of the (CuNb/Nb 3 Sn) Rutherford cable were investigated in high magnetic fields. The coil reached the maximum transport current of 1655 A at 4.2 K and 13.5 T after four times of training quenches. The electromagnetic stresses at the maximum transport current were 240 MPa at an inner surface of the coil and 210 MPa at an outer surface of the coil. The hoop strain of 0.2% for the coil was measured, which was applied at the outer surface of the coil. The strain value was the same as the calculated result using Wilson's equation and stress-strain curve of the strand.


  • Strain and magnetic field response of Ic in reinforced GdBCO coated conductor tapes at 77 K

    by H. S. Shin, M. Dedicatoria, A. Gorospe, J. R. Dizon, H. Oguro, S. Awaji

    Understanding the characteristic response of critical current, Ic with stress/strain under magnetic field is important for the application of coated conductor (CC) tapes to large scale superconducting coils or magnets. In this study, the strain and magnetic field effects on Ic in brass laminated reactive co-evaporation by deposition and reaction (RCE-DR) processed GdBCO CC tapes at 77 K were investigated. In the case of RCE-DR GdBCO CC tape samples with Hastelloy substrate, the additional lamination of brass foils to the Cu-stabilized only resulted in an increased irreversible strain limit of 0.50 % up to 0.80 %. But, not as much of these improvements were observed in CC samples having stainless steel substrate. Also, the additional brass laminate to all GdBCO CC tape samples did not affect the magnetic field response of Ic at 0 % strain. Under magnetic field, the strain response and tolerance of Ic was improved with additional brass laminates showing a much lower Ic reduction as compared with that at the irreversible strain limit of the Cu-stabilized CC samples. The strain sensitivity behavior of Ic under magnetic field (Ic-ε-B relation at 77 K) in RCE-DR GdBCO CC tapes was discussed.


  • Prebending Effect for Mechanical and Superconducting Properties of Nb-Rod-Processed Cu–Nb Internal-Reinforced $\hbox{Nb}_{3} \hbox{Sn}$ Wires

    by H. Oguro, S. Awaji, K. Watanabe, M. Sugimoto, H. Tsubouchi

    We are planning to develop three large superconducting magnets, using CuNb-reinforced Nb 3 Sn Rutherford cables with the prebending treatment. CuNb-reinforced Nb 3 Sn wires using a new Nb-rod-processed CuNb composite were developed for the Rutherford cables. In this study, the prebending effects for the mechanical and the superconducting properties of the Nb-rod-processed CuNb/Nb 3 Sn wire were investigated. We found that the CuNb/Nb 3 Sn wire with 0.8% prebending treatment had largely enhanced critical current at 4.2 K. The reduction of the n-value was observed around 0.8% prebending strain. The mechanical properties of the prebent wires were enhanced. Young's modulus and 0.2% proof stress of the wire with prebending treatment at 4.2 K are 180 GPa and 270 MPa, respectively. The residual strain was released from 0.30% to 0.15% by 0.8% prebending treatment.


  • HTS Coil Test Facility in a Large Bore 20 T Resistive Magnet at LNCMI

    by Y. Miyoshi, X. Chaud, F. Debray, B. Vincent, P. Tixador, T. Lecrevisse, J.-M. Rey, H. Oguro, S. Awaji, K. Watanabe, et al.

    The high temperature superconductor (HTS) coil development, especially in the interest of high field insert coil, requires characterizations of a prototype coil in high magnetic field. Our test probe fits into the bore of Ø 170 mm 20 T dc magnet, and the sample space Ø 130 mm allows test coils with ~Ø 110 mm and 140 mm height. A fast data acquisition method at sampling period of 0.1 ms was developed for coil quench test program, and a working principle of the method is demonstrated for a small test coil. To accommodate high current required in tests such as Ic and hoop stress tests, the new current leads were manufactured with an optimal current measured in the range of 600 ~ 700 A, which was sufficient for the envisaged coil tests. For short duration, the current lead could carry more than 1000 A without any influence of overheating in short sample Ic test. A demonstration of short sample Ic test is also presented.


  • Upgrade Design to a Cryogen-Free 20-T Superconducting Outsert for a 47-T Hybrid Magnet

    by K. Watanabe, S. Awaji, Y. Hou, H. Oguro, T. Kiyoshi, H. Kumakura, S. Hanai, H. Tsubouchi, M. Sugimoto, I. Inoue

    A Rutherford flat cable composed of sixteen 0.8-mm-diameter Nb 3 Sn strands with CuNb-reinforced stabilizers (CuNb/Nb 3 Sn) has been developed for use as an outsert for a 47-T hybrid magnet. To guarantee the safety of the magnet in the event of a quench, the low residual resistance ratio characteristic of arc-melted-in-situ CuNb composite had to be improved upon, and to obtain high electric conductivity, a new CuNb fabrication method using a Nb rod was attempted. The thermal runaway characteristics of chemical vapor deposition- YBa 2 Cu 3 O 7-δ (Y123) coated-conductor tapes with varying Cu stabilizer thicknesses were measured in magnetic fields of up to 10 T at temperatures ranging from 17 to 60 K. It was found that the ratio of the thermal runaway over-current to the critical current decreases as temperature decreases and that thermal runaway occurs just above the critical current level at 5 K. The properties of a cryogen-free, 20-T superconducting outsert for a 47-T hybrid magnet utilizing CuNb/Nb 3 Sn Rutherford flat cables and Y123 tapes and having a room temperature bore of 400 mm were investigated.


  • Relation Between the Crystal Axis and the Strain Dependence of Critical Current Under Tensile Strain for GdBCO Coated Conductors

    by H. Oguro, T. Suwa, T. Suzuki, S. Awaji, K. Watanabe, M. Sugano, S. Machiya, M. Sato, T. Koganezawa, T. Machi, et al.

    The strain and the critical current of the GdBCO coated conductor were investigated in order to understand the mechanism of the strain effect for a coated conductor. The internal strain behaviors of the longitudinal, width, and thickness directions were measured by the X-rays of the synchrotron radiation. From these results, the residual strains of a, b, and c-axes for the GdBCO crystal were estimated. In addition, the strain dependence of the critical current and the n-value at 4.2 and 77 K were measured under the tensile strain. The relationship between superconducting properties and the triaxial strain in the GdBCO crystal of the coated conductors is discussed.