HMHocine Mzad

Hocine Mzad

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hocine Mzad has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A simple graphical method for sizing flat‐plate solar air heaters based on transversal and longitudinal aspect ratios

    by Hocine Mzad, Fethi Bennour

    Solar air heaters (SAHs) are widely used for drying vegetables and fruits or for domestic heating. Certain sizing parameters are necessary to obtain the right dimensions for the required air temperature, flow rate, and thus useful thermal energy. The well‐known Hottel–Whillier–Bliss equation was used and made dimensionless by applying the collector longitudinal and transversal aspect ratios (rl and rt) of a double‐glazed flat plate solar air heater (DG‐FPSAH). The steady‐state equations are solved to determine the average temperatures. Thereafter, one could calculate the overall loss heat coefficient and efficiency factor, obtained analytically. A Matlab code was developed to estimate primarily unknown temperatures, useful energy, and the Nusselt number. An iterative numerical method is used until convergence occurs. The inlet cross‐sectional area and air flow velocity are defined as input data. The proposed sizing method depends on the output temperature required by the customer. This temperature can be determined from the plotted curves of the dimensionless ratios. Hence, the SAH‐needed dimensions are determined graphically depending on the functional requirements for construction planning, such as technology choice, work breakdown, and budgeting. In the present case study, based on the input parameters, an airflow rate of 1.2 kg/s entering a DG‐FPSAH with an output temperature of 41.5°C yields the dimensions of Lin = 3.824 m, Win = 2.735 m, and Hin = 0.1825, specifying the collector length, width, and air duct height. The gathered energy and thermohydraulic efficiency are: Qu = 7.91 kW, ηcol = 0.752, respectively.


  • Open Access

    Industrial gas turbine performance prediction and improvement – a case study

    by Hocine Mzad, Fethi Bennour

    The gas turbines (GTs), model M3142R/GE MS 3002, equipping the natural gas compression and crude oil pumping stations of SONATRACH’s pipeline transport of hydrocarbons activity are robust despite their dilapidation and state of service, but mediocre in terms of energy efficiency and power output. According to the manufacturer, for temperatures ranging from 15 to 47 °C, the efficiency of these machines drops from 26.78 to 25.03 % and their power drops from 11.29 to 8.9191 MW. It should be noted, however, that the number of these turbines exceeds 80 units and that their operation dates from 1974. The intention of this paper is to improve the gas turbine performance, mainly the efficiency and shaft power, by an evaporative cooling process of the compressor intake air. Besides, it is proposed to lower the upper limit power in periods of high temperatures to reduce gas consumption. To achieve these objectives, a mathematical model was implemented under Matlab R16, which reproduced the real behavior of these machines. It follows that this simulation made it possible to highlight relevant gains in terms of power and efficiency of the order of 1.361 MW and 3.4 % at a temperature of 47 °C.


  • Open Access

    Corrigendum to: A numerical investigation of optimum angles for solar energy receivers in the eastern part of Algeria

    by Fethi Bennour, Hocine Mzad

    Article Corrigendum to: A numerical investigation of optimum angles for solar energy receivers in the eastern part of Algeria was published on January 16, 2023 in the journal Energy Harvesting and Systems (volume 0, issue 0).


  • On the effect of the transversal aspect ratio on the double‐glazed solar air heater performance

    by Hocine Mzad, Fethi Bennour

    The transversal aspect ratio of solar air heaters (SAHs) is a critical geometric parameter that influences the heat transfer from the absorber plate to the working fluid and, accordingly, the overall heat loss level. The present work addresses the effect of the aspect ratio on the performance of a solar air heating system and the behavior of heat transfer coefficients (HTCs) within it and along the flow channel. A mathematical model of energy‐balance equations was formulated to examine and analyze the double‐glazed solar air heater thermal behavior. The Eismann correlation, which is more accurate than Holland's correlation, was employed to determine the HTC between the two glass covers. The useful energy, Nusselt number (Nu), efficiency, overall loss, and HTCs as a function of the aspect ratio were evaluated across the collector length. On the basis of the findings, the higher the ratio, the better the efficiency of the SAH. Indeed, increasing the collector's cross‐sectional aspect ratio (r) up to 19 increases useful energy efficiency by more than 87%, Nu by 84%, thermohydraulic efficiency from 0.4 to 0.76, and overall heat loss by 1.15 W/(m2 K). Furthermore, reducing r from 19 to 2 will improve the collector power from 1.855 to 3.473 kW.


  • A numerical investigation of optimum angles for solar energy receivers in the eastern part of Algeria

    by Fethi Bennour, Hocine Mzad

    The need to capture the maximum amount of solar energy and to optimize the panels’ collecting surfaces are among the primary objectives of research in solar engineering. The simplest way to accomplish this is to perform a monthly accurate determination of the solar collector’s proper slope and azimuth angles. Indeed, this is the aim of this article, which consists of a graphical optimization based on the Gueymard’s daily integration model. A Matlab program was developed to predict the hourly solar radiation on a solar receiver using the Gueymard model in conjunction with the Liu and Jordan isotropic, Perez, and HDKR anisotropic models. A comprehensive simulation of the monthly solar irradiation throughout 2018 was executed for the city of Annaba, in north–eastern Algeria. The results indicate that the south-facing surface azimuth angle is the most appropriate. In fact, for maximum sunlight capture, the solar collector inclination must be adjusted each month in the range of [10–40°]. Furthermore, the results show that the gains in the amount of solar radiation received throughout the year by the thermal panel mounted at monthly optimum tilt angles are 15.63% in January and 7.37% in July.


  • Open Access

    Thermal performance of a gas turbine based on an exergy analysis

    by Abdallah Haouam, Chaima Derbal, Hocine Mzad

    This work concerns the calculation and the analysis of the thermal performance of the components ofan MS 7001 type gas turbine with a nominal power of 87 MW using the concept of exergy. The exergy balance is used in addition to the energy balance to estimate the irreversibility of the air compressor, the combustion chamber and the turbine. The exergy analysis is carried out by applying the equilibrium equations obtained from the general definitions of the irreversibility of the thermodynamic processes and the data provided by the manufacturer. The results show that the exergy destruction of the gas turbine depends on the variation of the thermodynamic parameters: ambient temperature, compression ratio, air–fuel ratio. The combustion chamber has the highest exergy destruction estimated at 36.34 MW. The air compressor has an exergy efficiency of 84.19% that of the combustion chamber is 75.91% whilethat of the turbine expansion is 92.58%. The total exergy destruction of the gas turbine is 53.51 MW and itsefficiency is 32.44%. Improving the performance of the gas turbine requires decreasing the temperatureof the intake air.


  • Open Access

    A model of water-spray cooling effect on a continuous casting process

    by Hocine Mzad, Abdessalam Otmani, Kamel Bey, Stanisław Łopata

    The intention of this study is to give an idea about the influence of water-spray cooling on the solidification process of the liquid metal which enables to locate the shear region. The effect of spray heat transfer coefficient (h spray) during the liquid-to-solid transition through the cooled zone temperature and the metal latent heat of solidification are highlighted. A gray iron continuous casting process subjected to water-sprays cooling was simulated using the commercial code COMSOL MULTIPHYSICS 5.2. The obtained results show the great influence of h spray on the location of transition region as well as the relationship between h spray, wall outer temperature, latent heat dissipation, and the solidification time.