TATurkan Ormanci Acar

Turkan Ormanci Acar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Turkan Ormanci Acar has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Modelling of long-term permeability of compacted and consolidated clays permeated with leachate

    by M.ş. Özçoban, T. Ormanci-Acar, G. Turkoglu Demirkol, S. Gunes Durak, S.A. Aya, N. Tüfekci

  • Influence of nanoparticles on filterability of fruit-juice industry wastewater using submerged membrane bioreactor

    by Guler Turkoglu Demirkol, Nadir Dizge, Turkan Ormanci Acar, Oyku Mutlu Salmanli, Nese Tufekci

    In this study, polyethersulfone (PES) ultrafiltration membrane surface was modified with nano-sized zinc oxide (nZnO) and silver (nAg) to improve the membrane filterability of the mixed liquor and used to treat fruit-juice industry wastewater in a submerged membrane bioreactor (MBR). The nAg was synthesized using three different methods. In the first method, named as nAg-M1, PES membrane was placed on the membrane module and nAg solution was passed through the membrane for 24 h at 25 ± 1 °C. In the second method, named as nAg-M2, PES membrane was placed in a glass container and it was shaken for 24 h at 150 rpm at 25 ± 1 °C. In the third method, named as nAg-M3, Ag nanoparticles were loaded onto PES membrane in L-ascorbic acid solution (0.1 mol/L) at pH 2 for 24 h at 150 rpm at 25 ± 1 °C. For the preparation of nZnO coated membrane, nZnO nanoparticles solution was passed through the membrane for 24 h at 25 ± 1 °C. Anti-fouling performance of pristine and coated membranes was examined using the submerged MBR. The results showed that nZnO and nAg-M3 membranes showed lower flux decline compared with pristine membrane. Moreover, pristine and coated PES membranes were characterized using a permeation test, contact angle goniometer, and scanning electron microscopy.


  • Open Access

    Modeling of membrane fouling in a submerged membrane reactor using support vector regression

    by Serhan Aydin Aya, Turkan Ormanci Acar, Nese Tufekci

    Removal rate of Fe2+ and Mn2+ using submerged membrane reactor for drinking water in the presence of fulvic acid and iron hydroxide is studied using the data from the experiments obtained from various concentrations of Fe2+, Mn2+, fulvic acid, and iron hydroxide. The relationship between these contaminants and membrane fouling is investigated. In the experiments, flux is kept as constant, and the pressure change with time is observed. To model the relationship, a regression analysis using the support vector regression (SVR) model is presented. Hyperparameter optimization for SVR is important, that is, wrong selection may cause underfitting/overfitting phenomena. In order to find optimal values, grid search method is performed with various parameters such as different kernel functions (radial basis functions, polynomial, linear), cost parameter (C), and scale parameters γ and ε. The results obtained by SVR show that proposed method is feasible.


  • Open Access

    An experimental study on manganese(II) removal with manganese dioxide recycling

    by T. Ormanci, G. Turkoğlu Demirkol, İ.M. Aydın, N. Tufekci

    Manganese dioxide (MnO2) particles have a catalytic effect on removing Mn(II) from contaminated water. On the basis of this effect, a manganese removal process was proposed in this paper. For this purpose, the oxidation of Mn(II) was studied first in batch reactor and then in continuous reactor. The experimental conditionals for batch reactor were Mn(II): 3 mg/l, Mn(IV): 0–800 mg/l, pH: 9.6, temperature: 25 °C and for continuous system, the conditionals were kept the same except Mn(II) concentration. A quadratic equation was obtained as a function of Mn(IV) concentration to determine the catalytic reaction rate constant. It was experimentally demonstrated that there was no significant effect of Mn(IV) on the Mn(II) oxidation at Mn(IV) concentrations beyond 800 mg/l. Furthermore, reaction kinetics was derived from the data of batch experiments. Based upon the reaction kinetics, it has been theoretically demonstrated that the volume of aeration tank can be significantly reduced by keeping a high concentration of Mn(IV) in the reactor. Lastly, manganese oxidation was studied in a continuous flow lab scale system with and without MnO2 sludge recirculation. In this system, until Mn(IV) concentration had reached 300 mg/l, Mn(II) removal rate had increased linearly, but beyond this level increase had continued decreasingly. This study shows that, instead of using stronger oxidants in the drinking water treatment systems, recycling of MnO2 flocks provides important advantages like low investment cost, minimization of treatment area and, because of the lack of using oxidants, low operation cost.