Christoph A. Binkert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christoph A. Binkert has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Juerg Hodler
4 shared publicationsMarco Zanetti
2 shared publicationsRobert T. Andrews
2 shared publicationsA.C. Venbrux
1 shared publicationA.T. Drooz
1 shared publicationAndreas Pospischil
1 shared publication
Latest Publications
- 29 February 2008
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 19 (2) , S28
Abstract No. 69: Multicenter Retrievability Trial of the Recovery G2 Filter
- 29 February 2008
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 19 (2) , S28
Abstract No. 69: Multicenter Retrievability Trial of the Recovery G2 Filter
- 1 October 2002
- Published by Rockefeller University Press
- Vol. 37 (10) , 557-61
Laser-induced thermotherapy of the vertebral body: preliminary assessment of safety and real-time magnetic resonance monitoring in an animal model.
To evaluate the safety of percutaneous laser-induced thermotherapy (LITT) of vertebral bodies and the feasibility of monitoring the thermal effects with real-time magnetic resonance (MR) imaging. Laser fibers were placed in nine vertebral bodies of two minipigs under CT-guidance. LITT was performed in an open 0.5 T MR scanner using an Nd: YAG laser source. A T1-weighted MR sequence was used for continuous color-coded temperature monitoring. Histology of the vertebral body and spinal cord were subsequently obtained. Thermal lesions of the vertebral bodies measured 8 to 11 mm (mean 9.3 mm) in diameter. Thermal injuries of the spinal cord were observed in all four levels in which cortical bone surrounding the spinal canal was damaged during needle placement and in none with intact cortical bone. MR monitoring of the thermal effect was possible only if acquired in breath-hold technique. An intact cortical bone seems to be a prerequisite for safe LITT of the vertebral body. Real-time MR-monitoring of the thermal effect in vertebral bodies and the spinal canal was feasible with breath-hold acquisition. Larger studies are necessary to further evaluate accuracy of real-time MR imaging.
- 1 October 2002
- Published by Rockefeller University Press
- Vol. 37 (10) , 557-61
Laser-induced thermotherapy of the vertebral body: preliminary assessment of safety and real-time magnetic resonance monitoring in an animal model.
To evaluate the safety of percutaneous laser-induced thermotherapy (LITT) of vertebral bodies and the feasibility of monitoring the thermal effects with real-time magnetic resonance (MR) imaging. Laser fibers were placed in nine vertebral bodies of two minipigs under CT-guidance. LITT was performed in an open 0.5 T MR scanner using an Nd: YAG laser source. A T1-weighted MR sequence was used for continuous color-coded temperature monitoring. Histology of the vertebral body and spinal cord were subsequently obtained. Thermal lesions of the vertebral bodies measured 8 to 11 mm (mean 9.3 mm) in diameter. Thermal injuries of the spinal cord were observed in all four levels in which cortical bone surrounding the spinal canal was damaged during needle placement and in none with intact cortical bone. MR monitoring of the thermal effect was possible only if acquired in breath-hold technique. An intact cortical bone seems to be a prerequisite for safe LITT of the vertebral body. Real-time MR-monitoring of the thermal effect in vertebral bodies and the spinal canal was feasible with breath-hold acquisition. Larger studies are necessary to further evaluate accuracy of real-time MR imaging.
- 1 June 2002
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 13 (6) , 609-612
Lack of suitability of the rabbit model for particulate uterine artery embolization.
- 1 June 2002
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 13 (6) , 609-612
Lack of suitability of the rabbit model for particulate uterine artery embolization.
- 1 March 2002
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 25 (2) , 144-147
Two Fatal Complications after Parallel Tracheal-Esophageal Stenting
Two patients with malignant obstructions of both the trachea and esophagus underwent parallel stent placement with Gianturco-Rösch Z (GRZ) stents for palliation of symptoms. Fatal hemorrhage occurred in both patients 2 and 3 weeks after stent placement respectively. An autopsy performed on one of these patients demonstrated esophageal tissue necrosis and erosion with perforation of both the tracheal and esophageal walls at sites where the stent struts were in direct opposition, leading to bleeding from the esophageal venous plexus. GRZ stents have been successful in the treatment of both solitary tracheal and esophageal stenoses. However, parallel tracheal-esophageal stenting with GRZ stents places patients at high risk for complications due to the high radial force exerted by this particular stent and the minimal amount of intervening tissue between the two structures.
- 1 March 2002
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 25 (2) , 144-147
Two Fatal Complications after Parallel Tracheal-Esophageal Stenting
Two patients with malignant obstructions of both the trachea and esophagus underwent parallel stent placement with Gianturco-Rösch Z (GRZ) stents for palliation of symptoms. Fatal hemorrhage occurred in both patients 2 and 3 weeks after stent placement respectively. An autopsy performed on one of these patients demonstrated esophageal tissue necrosis and erosion with perforation of both the tracheal and esophageal walls at sites where the stent struts were in direct opposition, leading to bleeding from the esophageal venous plexus. GRZ stents have been successful in the treatment of both solitary tracheal and esophageal stenoses. However, parallel tracheal-esophageal stenting with GRZ stents places patients at high risk for complications due to the high radial force exerted by this particular stent and the minimal amount of intervening tissue between the two structures.
- 1 December 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 221 (3) , 775-778
Patient’s Assessment of Discomfort during MR Arthrography of the Shoulder
To assess patient discomfort during (a) intraarticular contrast material injection (arthrography) and (b) magnetic resonance (MR) imaging in patients referred for MR arthrography of the shoulder and to compare the relative discomfort associated with each part of the examination. With use of a visual analogue scale (VAS) and relative ratings, 202 consecutive patients referred for MR arthrography of the shoulder rated the expected discomfort and that actually experienced during both arthrography and MR imaging. The Student t test was used for statistical analysis. The average VAS score (0 = "did not feel anything," 100 = "unbearable") was 16.1 +/- 16.4 (SD) for arthrography and 20.2 +/- 25.0 for MR imaging. This difference was statistically significant (P =.036, paired t test). The discomfort experienced during arthrography was as expected in 90 (44.6%) patients, less than expected in 110 (54.4%), and worse than expected in two (1.0%). MR imaging-related discomfort was as expected in 114 (56.4%) patients, less than expected in 66 (32.7%), and worse in 22 (10.9%). Arthrography was rated worse than MR imaging by 53 (26.2%) patients, equal to MR imaging by 69 (34.2%), and less uncomfortable than MR imaging by 80 (39.6%). Arthrography-related discomfort was well tolerated, often less severe than anticipated, and rated less severe than MR imaging-related discomfort.
- 1 December 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 221 (3) , 775-778
Patient’s Assessment of Discomfort during MR Arthrography of the Shoulder
To assess patient discomfort during (a) intraarticular contrast material injection (arthrography) and (b) magnetic resonance (MR) imaging in patients referred for MR arthrography of the shoulder and to compare the relative discomfort associated with each part of the examination. With use of a visual analogue scale (VAS) and relative ratings, 202 consecutive patients referred for MR arthrography of the shoulder rated the expected discomfort and that actually experienced during both arthrography and MR imaging. The Student t test was used for statistical analysis. The average VAS score (0 = "did not feel anything," 100 = "unbearable") was 16.1 +/- 16.4 (SD) for arthrography and 20.2 +/- 25.0 for MR imaging. This difference was statistically significant (P =.036, paired t test). The discomfort experienced during arthrography was as expected in 90 (44.6%) patients, less than expected in 110 (54.4%), and worse than expected in two (1.0%). MR imaging-related discomfort was as expected in 114 (56.4%) patients, less than expected in 66 (32.7%), and worse in 22 (10.9%). Arthrography was rated worse than MR imaging by 53 (26.2%) patients, equal to MR imaging by 69 (34.2%), and less uncomfortable than MR imaging by 80 (39.6%). Arthrography-related discomfort was well tolerated, often less severe than anticipated, and rated less severe than MR imaging-related discomfort.
- 1 July 2001
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 24 (4) , 233-239
Can MR Measurement of Renal Artery Flow and Renal Volume Predict the Outcome of Percutaneous Transluminal Renal Angioplasty?
Purpose: Predicting therapeutic benefit from percutaneous transluminal renal angioplasty (PTRA) in patients with renal artery stenosis (RAS) remains difficult. This study investigates whether magnetic resonance (MR)-based renal artery flow measurements relative to renal parenchymal volume can predict clinical outcome following PTRA. Methods: The data on 23 patients (13 men, 10 women; age range 47–82 years, mean age 64 years) were analyzed. The indication for treatment was hypertension (n = 18) or renal insufficiency (n = 5). Thirty-four cases of RAS were identified: bilateral disease was manifest in 11 and unilateral disease in 12 patients. The MR imaging protocol included a breath-hold, cardiac-gated cine phase-contrast sequence for renal flow measurement and a fast multiplanar spoiled gradient-echo sequence for renal volume measurement. MR measurements were performed on the day prior to and the day following PTRA. Clinical success was defined as (a) a reduction in diastolic blood pressure > 15% or (b) a reduction in serum creatinine > 20%. Kidneys were categorized as normal volume or low volume. A renal flow index (RFI) was calculated by dividing the renal flow (ml/min) by the renal volume (cm3). Results: Clinical success was observed in 11 patients. Twelve patients did not benefit from angioplasty. Normal kidney volume was seen in 10 of 11 responders and in 8 of 12 nonresponders, resulting in a sensitivity of 91%, specificity of 33%, a positive predictive value (PPV) of 56% and a negative predictive value (NPV) of 80%. A RFI below a threshold of 1.5 ml/min/cm3 predicted successful outcome with 100% sensitivity, 33% specificity, 58% PPV, and 100% NPV. The combination of normal renal volume and a RFI below 1.5 ml/min/cm3 identified PTRA responders with a sensitivity of 91%, a specificity of 67%, a PPV of 71%, and a NPV of 89%. PTRA resulted in a greater increase in renal flow in responders compared with nonresponders (p < 0.001). Conclusion: A combination of cine phase-contrast MR renal flow and parenchymal volume measurements enables identification of patients benefiting from PTRA with a high sensitivity and NPV, but only moderate specificity and PPV.
- 1 July 2001
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 24 (4) , 233-239
Can MR Measurement of Renal Artery Flow and Renal Volume Predict the Outcome of Percutaneous Transluminal Renal Angioplasty?
Purpose: Predicting therapeutic benefit from percutaneous transluminal renal angioplasty (PTRA) in patients with renal artery stenosis (RAS) remains difficult. This study investigates whether magnetic resonance (MR)-based renal artery flow measurements relative to renal parenchymal volume can predict clinical outcome following PTRA. Methods: The data on 23 patients (13 men, 10 women; age range 47–82 years, mean age 64 years) were analyzed. The indication for treatment was hypertension (n = 18) or renal insufficiency (n = 5). Thirty-four cases of RAS were identified: bilateral disease was manifest in 11 and unilateral disease in 12 patients. The MR imaging protocol included a breath-hold, cardiac-gated cine phase-contrast sequence for renal flow measurement and a fast multiplanar spoiled gradient-echo sequence for renal volume measurement. MR measurements were performed on the day prior to and the day following PTRA. Clinical success was defined as (a) a reduction in diastolic blood pressure > 15% or (b) a reduction in serum creatinine > 20%. Kidneys were categorized as normal volume or low volume. A renal flow index (RFI) was calculated by dividing the renal flow (ml/min) by the renal volume (cm3). Results: Clinical success was observed in 11 patients. Twelve patients did not benefit from angioplasty. Normal kidney volume was seen in 10 of 11 responders and in 8 of 12 nonresponders, resulting in a sensitivity of 91%, specificity of 33%, a positive predictive value (PPV) of 56% and a negative predictive value (NPV) of 80%. A RFI below a threshold of 1.5 ml/min/cm3 predicted successful outcome with 100% sensitivity, 33% specificity, 58% PPV, and 100% NPV. The combination of normal renal volume and a RFI below 1.5 ml/min/cm3 identified PTRA responders with a sensitivity of 91%, a specificity of 67%, a PPV of 71%, and a NPV of 89%. PTRA resulted in a greater increase in renal flow in responders compared with nonresponders (p < 0.001). Conclusion: A combination of cine phase-contrast MR renal flow and parenchymal volume measurements enables identification of patients benefiting from PTRA with a high sensitivity and NPV, but only moderate specificity and PPV.
- 1 July 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 220 (1) , 219-224
MR Arthrography of the Glenohumeral Joint: Two Concentrations of Gadoteridol versus Ringer Solution as the Intraarticular Contrast Material
To compare two concentrations of gadoteridol with Ringer solution as the contrast material for magnetic resonance (MR) arthrography of the glenohumeral joint. One hundred fifty-six consecutive MR arthrograms were randomly obtained with either 2 mmol/L gadoteridol (n = 52), 4 mmol/L gadoteridol (n = 52), or Ringer solution (n = 52). MR arthrograms were assessed quantitatively (for contrast-to-noise ratio [CNR]) and qualitatively (for overall image quality, image contrast, degree of joint distention, and motion artifacts). MR diagnoses were compared with arthroscopic or surgical reports in 88 patients. The mean CNR at imaging was 40.4 with 2 mmol/L gadoteridol, 45.6 with 4 mmol/L gadoteridol, and 48.7 with Ringer solution. The CNR with 2 mmol/L gadoteridol was significantly lower than that with 4 mmol/L gadoteridol (P =.025) and Ringer solution (P =.012). Qualitative differences between the two gadoteridol concentrations were not significant. Ringer solution was significantly worse with regard to overall quality, motion artifacts, image contrast, and joint distention compared with both gadoteridol concentrations. Ringer solution was slightly more sensitive and less specific than the gadoteridol solutions in the detection of supraspinatus tears and less sensitive and more specific in enabling diagnosis of superior labrum anteroposterior lesions. MR arthrograms of the shoulder obtained with gadoteridol and those obtained with Ringer solution provided equivalent diagnostic accuracy. The authors, however, preferred the image quality of the gadoteridol-enhanced arthrograms.
- 1 July 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 220 (1) , 219-224
MR Arthrography of the Glenohumeral Joint: Two Concentrations of Gadoteridol versus Ringer Solution as the Intraarticular Contrast Material
To compare two concentrations of gadoteridol with Ringer solution as the contrast material for magnetic resonance (MR) arthrography of the glenohumeral joint. One hundred fifty-six consecutive MR arthrograms were randomly obtained with either 2 mmol/L gadoteridol (n = 52), 4 mmol/L gadoteridol (n = 52), or Ringer solution (n = 52). MR arthrograms were assessed quantitatively (for contrast-to-noise ratio [CNR]) and qualitatively (for overall image quality, image contrast, degree of joint distention, and motion artifacts). MR diagnoses were compared with arthroscopic or surgical reports in 88 patients. The mean CNR at imaging was 40.4 with 2 mmol/L gadoteridol, 45.6 with 4 mmol/L gadoteridol, and 48.7 with Ringer solution. The CNR with 2 mmol/L gadoteridol was significantly lower than that with 4 mmol/L gadoteridol (P =.025) and Ringer solution (P =.012). Qualitative differences between the two gadoteridol concentrations were not significant. Ringer solution was significantly worse with regard to overall quality, motion artifacts, image contrast, and joint distention compared with both gadoteridol concentrations. Ringer solution was slightly more sensitive and less specific than the gadoteridol solutions in the detection of supraspinatus tears and less sensitive and more specific in enabling diagnosis of superior labrum anteroposterior lesions. MR arthrograms of the shoulder obtained with gadoteridol and those obtained with Ringer solution provided equivalent diagnostic accuracy. The authors, however, preferred the image quality of the gadoteridol-enhanced arthrograms.
- 6 May 2000
- Vol. 130 (18) , 645-51
Functional MR imaging of the craniocervical junction. Correlation with alar ligaments and occipito-atlantoaxial joint morphology: a study in 50 asymptomatic subjects.
Whiplash injuries are frequent in industrialized countries. The acute and chronic symptoms following such injuries are incompletely understood and objective clinical or imaging findings are rare. Several authors have suspected that rear end collisions occurring when the head is rotated may result in tears of the alar ligaments. There has been experimental proof that a torn alar ligament increases the rotation of the C0/C1 and C1/C2 segments to the contralateral side. Functional cross sectional imaging has therefore been proposed to diagnose injuries of the alar ligaments. So far, published data on normal ranges of rotation in an asymptomatic population have been sparse. The aim of this study was to determine by MR imaging the normal range of rotation in the first three cervical segments and their relation to the morphology of the alar ligaments and the occipito-atlantoaxial joints. Functional MR imaging of the craniocervical junction in maximum active left and right head rotation was performed in 50 healthy volunteers with a mean age of 29.8 years (31 men, 19 women, range 19-47 years). Measurements were independently performed by two musculoskeletal radiologists to assess interobserver error. The results were correlated with gender and age, with morphological findings in the occipito-atlantoaxial joints (i.e. joint symmetry, joint effusions, dens position), and with the form, course and symmetry of the alar ligaments. The mean range of rotation for the C0/C1 joint was 2.7 degrees (standard deviation [SD] 3.3 degrees)/3.3 degrees (SD 3.6 degrees) (right/left) and at the C1/C2 level 38 degrees (SD 6.5 degrees)/37.8 degrees (SD 6.4 degrees). The mean differences in left/right rotation were: C0/C1 3.5 degrees (SD 2.8 degrees) and C1/C2 6.3 degrees (SD 4.4 degrees). No correlation was found between segmental rotation and morphological characteristics of the craniocervical joints or ligament structures. There is wide variation of segmental motion in the upper cervical spine. Differences in right-to-left rotation are frequently encountered in an asymptomatic population. Therefore, these measurements are unsuitable for indirect diagnosis of soft tissue lesions after whiplash injury and should not be used as a basis for treatment guidelines.
- 6 May 2000
- Vol. 130 (18) , 645-51
Functional MR imaging of the craniocervical junction. Correlation with alar ligaments and occipito-atlantoaxial joint morphology: a study in 50 asymptomatic subjects.
Whiplash injuries are frequent in industrialized countries. The acute and chronic symptoms following such injuries are incompletely understood and objective clinical or imaging findings are rare. Several authors have suspected that rear end collisions occurring when the head is rotated may result in tears of the alar ligaments. There has been experimental proof that a torn alar ligament increases the rotation of the C0/C1 and C1/C2 segments to the contralateral side. Functional cross sectional imaging has therefore been proposed to diagnose injuries of the alar ligaments. So far, published data on normal ranges of rotation in an asymptomatic population have been sparse. The aim of this study was to determine by MR imaging the normal range of rotation in the first three cervical segments and their relation to the morphology of the alar ligaments and the occipito-atlantoaxial joints. Functional MR imaging of the craniocervical junction in maximum active left and right head rotation was performed in 50 healthy volunteers with a mean age of 29.8 years (31 men, 19 women, range 19-47 years). Measurements were independently performed by two musculoskeletal radiologists to assess interobserver error. The results were correlated with gender and age, with morphological findings in the occipito-atlantoaxial joints (i.e. joint symmetry, joint effusions, dens position), and with the form, course and symmetry of the alar ligaments. The mean range of rotation for the C0/C1 joint was 2.7 degrees (standard deviation [SD] 3.3 degrees)/3.3 degrees (SD 3.6 degrees) (right/left) and at the C1/C2 level 38 degrees (SD 6.5 degrees)/37.8 degrees (SD 6.4 degrees). The mean differences in left/right rotation were: C0/C1 3.5 degrees (SD 2.8 degrees) and C1/C2 6.3 degrees (SD 4.4 degrees). No correlation was found between segmental rotation and morphological characteristics of the craniocervical joints or ligament structures. There is wide variation of segmental motion in the upper cervical spine. Differences in right-to-left rotation are frequently encountered in an asymptomatic population. Therefore, these measurements are unsuitable for indirect diagnosis of soft tissue lesions after whiplash injury and should not be used as a basis for treatment guidelines.