AHAnnemieke Van Haver

Annemieke Van Haver

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Annemieke Van Haver has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Karel De Roo

    Department of Physical medicine and orthopaedic surgery, Ghent University, Ghent, Belgium

    4 shared publications
  • Matthieu De Beule

    Department of Civil Engineering, IBiTech-bioMMeda, Ghent University, Ghent, Belgium

    4 shared publications
  • Peter Verdonk

    Department of Physical medicine and orthopaedic surgery, Ghent University, Ghent, Belgium Antwerp Orthopedic Center, Monica Hospitals, Antwerp, Belgium

    4 shared publications
  • Patrick De Baets

    Department of Construction and Production, Ghent University, Ghent, Belgium

    3 shared publications
  • Tom Claessens

    Department of Materials, Textiles and Chemical Engineering, Ghent University, Ghent, Belgium

    3 shared publications
  • Luc Labey

    Department of Mechanical Engineering-Division of Biomechanics, Catholic University Leuven, Leuven, Belgium

    2 shared publications

Latest Publications

  • Effect of femoro-tibial component size mismatch on outcome in primary total knee replacement

    by Steven Heylen, Knud Foubert, Annemieke Van Haver, Paul Nicolai


  • The Effect of Trochlear Dysplasia on Patellofemoral Biomechanics

    by Annemieke Van Haver, Karel De Roo, Matthieu De Beule, Luc Labey, Patrick De Baets, David Dejour, Tom Claessens, Peter Verdonk

    Background: Trochlear dysplasia appears in different geometrical variations. The Dejour classification is widely used to grade the severity of trochlear dysplasia and to decide on treatment. Purpose: To investigate the effect of trochlear dysplasia on patellofemoral biomechanics and to determine if different types of trochlear dysplasia have different effects on patellofemoral biomechanics. Study Design: Controlled laboratory study. Methods: Trochlear dysplasia was simulated in 4 cadaveric knees by replacing the native cadaveric trochlea with different types of custom-made trochlear implants, manufactured with 3-dimensional printing. For each knee, 5 trochlear implants were designed: 1 implant simulated the native trochlea (control condition), and 4 implants simulated 4 types of trochlear dysplasia. The knees were subjected to 3 biomechanical tests: a squat simulation, an open chain extension simulation, and a patellar stability test. The patellofemoral kinematics, contact area, contact pressure, and stability were compared between the control condition (replica implants) and the trochlear dysplastic condition and among the subgroups of trochlear dysplasia. Results: The patellofemoral joint in the trochlear dysplastic group showed increased internal rotation, lateral tilt, and lateral translation; increased contact pressures; decreased contact areas; and decreased stability when compared with the control group. Within the trochlear dysplastic group, the implants graded as Dejour type D showed the largest deviations for the kinematical parameters, and the implants graded as Dejour types B and D showed the largest deviations for the patellofemoral contact areas and pressures. Conclusion: Patellofemoral kinematics, contact area, contact pressure, and stability are significantly affected by trochlear dysplasia. Of all types of trochlear dysplasia, the models characterized with a pronounced trochlear bump showed the largest deviations in patellofemoral biomechanics. Clinical Relevance: Investigating the relationship between the shape of the trochlea and patellofemoral biomechanics can provide insight into the short-term effects (maltracking, increased pressures, and instability) and long-term effects (osteoarthritis) of different types of trochlear dysplasia. Furthermore, this investigation provides an empirical explanation for better treatment outcomes of trochleoplasty for Dejour types B and D dysplasia.


  • The use of rapid prototyped implants to simulate knee joint abnormalities for in vitro testing: A validation study with replica implants of the native trochlea

    by Annemieke Van Haver, Karel De Roo, Matthieu De Beule, Sofie Van Cauter, Luc Labey, Patrick De Baets, Tom Claessens, Peter Verdonk

    To investigate the biomechanical effect of skeletal knee joint abnormalities, the authors propose to implant pathologically shaped rapid prototyped implants in cadaver knee specimens. This new method was validated by replacing the native trochlea by a replica implant on four cadaver knees with the aid of cadaver-specific guiding instruments. The accuracy of the guiding instruments was assessed by measuring the rotational errors of the cutting planes (on average 3.01° in extension and 1.18° in external/internal rotation). During a squat and open chain simulation, the patella showed small differences in its articulation with the native trochlea and the replica trochlea, which could partially be explained by the rotational errors of the implants. This study concludes that this method is valid to investigate the effect of knee joint abnormalities with a replica implant as a control condition to account for the influence of material properties and rotational errors of the implant.


  • A statistical shape model of trochlear dysplasia of the knee

    by A. Van Haver, P. Mahieu, T. Claessens, H. Li, C. Pattyn, P. Verdonk, E.A. Audenaert


  • Semi‐automated landmark‐based 3D analysis reveals new morphometric characteristics in the trochlear dysplastic femur

    by Annemieke Van Haver, Karel De Roo, Matthieu De Beule, Sofie Van Cauter, Emmanuel Audenaert, Tom Claessens, Peter Verdonk

    Purpose: The authors hypothesise that the trochlear dysplastic distal femur is not only characterised by morphological changes to the trochlea. The purpose of this study is to describe the morphological characteristics of the trochlear dysplastic femur in and outside the trochlear region with a landmark‐based 3D analysis.Methods: Arthro‐CT scans of 20 trochlear dysplastic and 20 normal knees were used to generate 3D models including the cartilage. To rule out size differences, a set of landmarks were defined on the distal femur to isotropically scale the 3D models to a standard size. A predefined series of landmark‐based reference planes were applied on the distal femur. With these landmarks and reference planes, a series of previously described characteristics associated with trochlear dysplasia as well as a series of morphometric characteristics were measured.Results: For the previously described characteristics, the analysis replicated highly significant differences between trochlear dysplastic and normal knees. Furthermore, the analysis showed that, when knee size is taken into account, the cut‐off values of the trochlear bump and depth would be 1 mm larger in the largest knees compared to the smallest knees. For the morphometric characteristics, the analysis revealed that the trochlear dysplastic femur is also characterised by a 10 % smaller intercondylar notch, 6–8 % larger posterior condyles (lateral–medial) in the anteroposterior direction and a 6 % larger medial condyle in the proximodistal direction compared to a normal femur.Conclusions: This study shows that knee size is important in the application of absolute metric cut‐off values and that the posterior femur also shows a significantly different morphology.


  • Pilot validation study on a quasi-static weight-bearing knee rig

    by Annemieke Van Haver, Karel De Roo, Tom Claessens, Matthieu De Beule, Peter Verdonk, Patrick De Baets

    This article presents a pilot study on a quasi-static knee rig designed to investigate the influence of pathologies and surgical interventions on the patellofemoral kinetics of cadaveric knees. The knee rig allows cadaveric knees to flex and extend under a simulated body weight by transmitting a force to the quadriceps tendon. During the squat simulation, the ground reaction force stays within physiological values. Before using this device to answer clinical questions, two knee specimens were tested to assess the repeatability of the rig. Four repeated flexion–extension cycles were performed under a simulated body weight of 700 N, with an isolated force on the quadriceps tendon up to 2700 N and with a ground reaction force close to 350 N. The resulting patellofemoral contact area shifted from distal to proximal during knee flexion. From 20° to 60° of knee flexion, the mean contact area and pressure increased from 80.2 ± 3.3 to 349.5 ± 10.1 mm2 and from 0.9 ± 0.2 to 5.9 ± 0.7 MPa, respectively. The transmitted force on the quadriceps tendon, the ground reaction force and the patellofemoral contact area and pressure were continuously measured and showed a relative variability of 1.6%, 2.4%, 2.8% and 3.2%, respectively. The presented knee rig shows a good repeatability that allows us to use this knee rig to quantify the influence of anatomical changes on the patellofemoral contact area and pressures during a squat simulation.