CSChristoph Thomas Starck

Christoph Thomas Starck

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christoph Thomas Starck has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    External validation of scores proposed for estimation of survival probability of patients with severe adult respiratory distress syndrome undergoing extracorporeal membrane oxygenation therapy: a retrospective study

    by Stephanie Klinzing, Urs Wenger, Peter Steiger, Christoph Thomas Starck, Markus Wilhelm, Reto A Schuepbach, Marco Maggiorini

    Introduction: This study was designed as an external validation of the recently proposed Predicting Death for Severe ARDS on V-V ECMO (PRESERVE) score, The respiratory extracorporeal membrane oxygenation survival prediction (RESP) score and a scoring system developed for externally retrieved patients on extracorporeal membrane oxygenation (ECMO) at our institution. All scores are proposed for the estimation of survival probability after ECMO treatment for severe adult respiratory distress syndrome. Methods: Data from 51 patients (2008 to 2013) were analyzed in this retrospective single-center study. A calculation of an adapted PRESERVE score, the RESP score as well as the score developed for externally retrieved ECMO patients was performed. Results: Seventy one percent of patients received veno-venous (v-v) and 29% venous-arterial (v-a) ECMO support during the study period. Overall survival at 6 months was 55%, with a 61% survival rate for v-v cannulated patients and a 40% survival rate for v-a cannulated patients. The PRESERVE score discriminated survivors and non-survivors with an area under the curve of 0.67 (95% CI 0.52 to 0.82, P = 0.03). Analyzing survival prediction according to cannulation modus, the PRESERVE score and the RESP score significantly predicted survival for patients on v-v ECMO with an area under the curve of 0.75 (95% CI 0.57 to 0.92, P = 0.01) and 0.81 (95% CI 0.67 to 0.95, P = 0.035), respectively, while the scoring system developed for externally retrieved ECMO patients failed to predict survival in our study population. All scores failed to predict mortality for patients on v-a ECMO. Conclusion: Our single-center validation confirms that the proposed PRESERVE and RESP score predict survival for patients treated with v-v ECMO for severe adult respiratory distress syndrome.


  • Open Access

    Impact of a femoral snare approach as a bailout procedure on success rates in lead extractions

    by Christoph Thomas Starck, Etem Caliskan, Holger Klein, Jan Steffel, Volkmar Falk

    In cases of challenging transvenous lead extraction procedures, limitations exist for the subclavian approach (SCA). In case of absent alternative approaches, the procedure may end with failure. Therefore, we investigated the femoral snare approach (FSA) as bailout procedure. From December 2010 to August 2013, 114 patients with 190 leads were scheduled for transvenous lead extraction procedures [mean implant duration (MID): 74.7 (1–384) months]. In 28 leads [MID: 133.8 (36–384) months] the FSA was used. In 20 leads [MID: 127.5 (52–258) months] the FSA was performed as bailout approach and in 8 leads [MID: 149.6 (36–384) months] as first-line approach due to complete intravascular lead position. In all FSA procedures (n = 28), clinical success was 85.7% and complete procedural success 64.3%. In FSA procedures as bailout approach (n = 20), clinical success was 80.0% and complete procedural success 55.0%. In first-line FSA procedures (n = 8), clinical success was 100.0% and complete procedural success 87.5%. Overall (n = 190) clinical success was 96.3%, complete procedural success 91.1%. By adding the FSA in cases of insufficient or impossible SCA, clinical success was increased by 12.6% (from 83.7 to 96.3%) and complete procedural success by 9.5% (from 81.6 to 91.1%). Comparison of leads extracted by SCA with leads extracted by FSA revealed that MID [133.8 (36–384) vs 64.4 (1–300) months; P < 0.0001] and the rate of passive fixation leads (67.9 vs 28.4%; P < 0.0001) were significantly higher in the FSA group. In cases of failed or impossible subclavian approach, the femoral snare approach may improve overall success rates without relevantly increasing operative risk.


  • Results of transvenous lead extraction of coronary sinus leads in patients with cardiac resynchronization therapy

    by Christoph T. Starck, Etem Caliskan, Holger Klein, Jan Steffel, Felix Schoenrath, Volkmar Falk

    Background The need for transvenous lead extraction procedures of coronary sinus (CS) leads is increasing due to rising numbers of implanted cardiac resynchronization therapy devices during the past decade. Methods From January 2009 to June 2013, 27 CS leads were scheduled for extraction in 27 patients (mean age (63.1±14.6) years). Indications for lead extraction were infection in 13 and lead dysfunction in 14 cases. Isolated extraction of CS leads was performed in eight, extraction of multiple leads in 19 cases. Among leads with an implant time of ≥12 months (n=19) mean implant duration (MID) was (46.4±15.2) (12-76) months. Groups were formed depending on infectious or non-infectious indications (INF vs. Non-INF), and the use or non-use of extraction tools (ET1 vs. ET0). Results Among patients with an implant duration of ≥12 months, complete procedural success was 94.7% and clinical success 100%. Operative mortality was zero. In the INF versus NON-INF groups complete procedural success (100% vs. 91.7%, P=0.43), mean number of required extraction tools (0.7 (0-2) vs. 0.9 (0-3), P=0.65) and MID (49.1±15.0 vs. 44.7±15.8, P=0.83) did not differ significantly. Comparing the groups ET1 and ET0 showed no significant differences in complications (n=1 vs. n=1, P=0.81) and MID (47.0±17.5 vs. 45.5±12.6, P=0.71). Conclusions In specialized centers transvenous lead extraction of coronary sinus leads with a mean implant duration of almost four years can be performed safely and effectively. Neither non-infectious indications nor the use of extraction tools negatively affected the outcome of the procedure.


  • Open Access

    Concept and first experimental results of a new ferromagnetic assist device for extra-aortic counterpulsation

    by Christoph T. Starck, Jakob Becker, Roland Fuhrer, Simon Sündermann, Jan Wendelin Stark, Volkmar Falk

    Based on a ferromagnetic silicone cuff for extra-aortic counterpulsation, a new assist device concept was developed. The driving force is generated by an external magnetic field, which leads to contraction of a soft magnetic cuff. The force generation capacity of the device was tested in a silicone aorta model. Magnetic elastomers can be constructed through dispersion of micro- or nanoparticles in polymer matrices and were designed to act as soft actuators. Two magnetically active silicone cuffs were produced with a nanomagnet loading of 250 wt% (Cuff 1) and a micromagnet loading of 67 wt% (Cuff 2). The magnetic cuffs were applied on a silicone aorta model and contracted against hydrostatic pressure. A full contraction of Cuff 1 was possible against a maximal hydrostatic pressure of 30 cmH2O (22 mmHg) at a magnetic flux density of 0.4 T (Tesla) and 65 cmH2O (48 mmHg) at a magnetic flux density of 1.2 T. A 50% contraction of Cuff 2 was possible against a maximal hydrostatic pressure of 80 cmH2O (59 mmHg) at a magnet-cuff-distance (MCD) of 0 cm. At MCDs of 1 and 2 cm a 50% contraction was possible against 33 cmH2O (24 mmHg) and 10 cmH2O (7 mmHg), respectively. Combining the advantages of magnetic elastomers with the principle of extra-aortic counterpulsation in a new assist device concept avoids the need for anticoagulation (no contact with bloodstream). With regard to the magnetic principle of action, no intra- to extracorporeal connection is needed. More experimental work is needed to further increase the force generated by the silicone cuff and to transfer the device concept into an in vivo setting.


  • Generator Pocket Adhesions of Cardiac Leads: Classification and Correlation with Transvenous Lead Extraction Results

    by Hector Rodriguez Cetina Biefer, David Hürlimann, Jürg Grünenfelder, Sacha P. Salzberg, Jan Steffel, Volkmar Falk, Christoph T. Starck

    Objectives: Pacemaker (PM) and implantable cardioverter defibrillator (ICD) leads become encapsulated intravascularly and in the generator pocket by fibrotic adhesions that accumulate over time. These adhesions are responsible for the difficulty and risk of lead extraction procedures. We developed a classification scheme for pocket adhesions, classified all of the patients in the cohort, and examined the relationship between pocket adhesions and the outcome of the procedure.Methods: The classification of adhesions with respect to the intraoperative adhesion coverage was as followed: class 0 = adhesion free; class 1 ≤ 30% of adhesion coverage; class 2 = 30–60% of adhesion coverage; and class 3 ≥ 60% coverage. Patient data between December 2010 and March 2012 were collected. A total of 100 leads were extracted from 58 patients (1.7 ± 0.8 leads/patient); the mean lead implant duration was 78.5 ± 66.7 months, and the percentage of PM/ICD leads was 68% (n = 68)/32% (n = 32).Results: Distribution of the leads among classes: 0 = 10; 1 = 17; 2 = 25; and 3 = 48. Average implant times (months) according to the adhesion classes: 0 = 1.2 ± 0.4; 1 = 19.8 ± 19.2; 2 = 79.3 ± 46.6; and 3 = 115.1 ± 106.0 (correlation‐coefficient 0.71; P ≤ 0.05). Average numbers of extraction tools used according to the adhesions: 0 = none; 1 = 0.4 ± 0.7; 2 = 1.6 ± 1.0; and 3 = 2.3 ± 1.2 (correlation coefficient = 0.67; P ≤ 0.05). Complete removal was achieved in 100% of the patients in classes 0 and 1; 96% in class 2 (n = 24); and 75% in class 3 (n = 36) (P ≤ 0.05). Mortality = 0.Conclusions: Extensive adhesions in the generator pocket predict the need for a higher number of extraction tools. High‐grade pocket adhesions predict lower success rates with regard to complete lead extraction. Both findings suggest that the degree of pocket adhesions predicts the degree of intravascular adhesions.


  • Open Access

    Transvenous lead extractions: comparison of laser vs. mechanical approach

    by Christoph T. Starck, Hector Rodriguez, David Hürlimann, Jürg Grünenfelder, Jan Steffel, Sacha P. Salzberg, Volkmar Falk

    In this retrospective study we compared different lead extraction techniques. Between January 2009 and December 2012 we performed transvenous lead extraction procedures on 206 leads in 122 patients. Mean implant duration (MID) was 69.6 months (1–384 months). Leads with lead implant duration ≥ 12 months were assigned to groups according to the extraction technique: Group A: no extraction tool; Group B: laser approach; and Group C: mechanical approach. Overall clinical success was 93.3%. Group A showed a significantly lower MID [38.1 (19–122) months] compared with Groups B and C [83.1 (13–168) months; P < 0.0001 vs. 95.4 (12–384) months; P < 0.0001]. Mean implant duration between Groups B and C did not differ significantly (P = 0.28). Clinical and complete procedural success was 100% in Group A. Clinical success rate was higher in Group C than in Group B (97.0 vs. 76.9%, P = 0.018). Complete procedural success did not differ significantly between Groups B and C (88.9 vs. 76.9%; P = 0.132). In Groups B and C, absence of complete procedural success occurred in long implanted leads (MID 107.8 ± 36.4 and 137.6 ± 89.2 months). Relative costs per extracted lead were 49% higher in Group B than in Group C. In case of long implanted leads a laser and a mechanical approach are comparable in complete procedural success and safety. Clinical success and cost effectiveness analysis favours the mechanical approach. Regardless of the extraction technique efficacy and safety optimization has to focus on long implanted leads.


  • Open Access

    Interhospital transfer of seriously sick ARDS patients using veno-venous Extracorporeal Membrane Oxygenation (ECMO): Concept of an ECMO transport team

    by Christoph T Starck, Peter Hasenclever, Volkmar Falk, Markus J Wilhelm

    Background: Extracorporeal membrane oxygenation (ECMO) therapy constitutes the last option for patients with acute respiratory distress syndrome (ARDS) refractory to conservative treatment. Since primary care centers are unable to provide this therapy, such patients need a transfer to a tertiary care center, which may be life-threatening without extracorporeal support. Methods: An ECMO transport team implanted an ECMO at the site of the primary care center with subsequent transport of the patient to the tertiary care center. Between September 2009 and March 2011, six patients with ARDS were treated by our ECMO transport team. Mean age was 39.5±12.0 years. All implantations were done percutaneously in a veno-venous configuration. Results: No complications occurred during the implant procedure and the subsequent transport. Four patients (67%) were successfully weaned from ECMO-therapy, and discharged from hospital. Conclusion: With a specialized ECMO transport team, ECMO-implantation can be achieved successfully in a peripheral hospital, and patients can be transported safely.