MDMarco Delcogliano

Marco Delcogliano

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marco Delcogliano has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Treatment of osteochondritis dissecans of the knee with a biomimetic scaffold. A prospective multicenter study

    by Marco Delcogliano, Amerigo Menghi, Giacomo Placella, Andrea Speziali, Giuliano Cerulli, Giulia Carimati, Stefano Pasqualotto, Massimo Berruto

    Purpose: the aim of the present study was to evaluate the clinical outcome of the treatment of osteochondritis dissecans (OCD) of the knee with a type-I collagen-hydroxyapatite nanostructural biomimetic osteochondral scaffold. Methods: twenty-three patients affected by symptomatic knee OCD of the femoral condyles, grade 3 or 4 of the International Cartilage Repair Society (ICRS) scale, underwent biomimetic scaffold implantation. The site of the defect was the medial femoral condyle in 14 patients, whereas in 9 patients the lateral femoral condyle was involved. The average size of the defects was 3.5±1.43 cm2. All patients were clinically evaluated using the ICRS subjective score, the IKDC objective score, the EQ-VAS and the Tegner Activity Score. Minimum follow-up was two years. MRI was performed at 12 and 24 months after surgery and then every 12 months thereafter. Results: the ICRS subjective score improved from the baseline value of 50.93±20.6 to 76.44±18.03 at the 12 months (p<0.0005) and 82.23± 17.36 at the two-year follow-up (p<0.0005). The IKDC objective score confirmed the results.The EQ-VAS showed a significant improvement from 3.15±1.09 to 8.15±1.04 (p<0.0005) at two years of follow-up. The Tegner Activity Score improvement was statistically significant (p<0.0005). Conclusions: biomimetic scaffold implantation was a good procedure for treating grade 3 and 4 OCD, in which other classic techniques are burdened by different limitations. This open one-step surgery gave promising stable results at short-term follow-up. Level of evidence: Level IV, therapeutic case series.


  • Treatment of Large Knee Osteochondral Lesions With a Biomimetic Scaffold

    by Massimo Berruto, Marco Delcogliano, Francesca de Caro, Giulia Carimati, Francesco Uboldi, Paolo Ferrua, Giovanni Ziveri, Carlo Felice De Biase

    Background: Osteochondral knee lesions represent a challenging condition encountered by orthopaedic surgeons. A variety of methods have been developed to repair articular cartilage defects. However, these techniques are limited by donor site morbidity or by the requirement for a staged procedure. Purpose: To assess the effectiveness of a biomimetic osteochondral scaffold for the treatment of large osteochondral knee lesions. Study Design: Case series; Level of evidence, 4. Methods: From 2009 to 2011, a total of 49 patients affected by isolated large osteochondral knee lesions (mean [± SD] size, 4.35 ± 1.26 cm 2 ) were treated with the biomimetic scaffold. Patients were evaluated using the International Knee Documentation Committee (IKDC), Tegner, and visual analog scale (VAS) pain scores, as well as magnetic resonance imaging (MRI) up to 3-year follow-up. The MOCART (magnetic resonance observation of cartilage repair tissue) score was performed to analyze different variables. Biopsies were carried out in 5 patients. Four of the 5 second-look arthroscopies and biopsies were performed on patients with failed results because of ethical issues. Results: The mean IKDC subjective score increased significantly from 45.45 ± 19.29 preoperatively to 70.86 ± 18.08 at 1-year follow-up and to 75.42 ± 19.31 at 2-year follow-up ( P < .001). The IKDC objective score changed from 50% normal and nearly normal knees before treatment to 89.79% at the 2-year follow-up. There was a statistically significant improvement ( P < .005) in VAS score from the preoperative level (6.69 ± 1.88) to the 2-year follow-up (1.96 ± 2.47). Tegner scores increased ( P < .001) from the preoperative value (2.20 ± 0.67) to the 2-year follow-up (4.9 ± 1.73) without achieving preinjury level. A correlation was found between the IKDC subjective score and age ( P < .001, r = −0.497, ρ = −0.502). Patients affected by osteochondritis dissecans (OCD) achieved a statistically significantly better outcome ( P < .05). A subgroup of 19 competitive athletes showed a statistically significantly improvement ( P < .001) in the subjective IKDC (86.5 ± 13.2) compared with the nonathletic subpopulation (69.03 ± 19.41) at the 2-year follow-up. The MRI findings of 30 patients were available at 2-year follow-up: 70% showed complete filling of the lesion, 63.3% had an intact articular surface, and 86% had mild or no effusion. In all cases, in dual T2-weighted fast spin echo sequence, the repair tissue showed a hyperintensive signal with respect to the surrounding subchondral bone; however, no edema was observed. Conclusion: The study findings indicate that the biomimetic scaffold that was investigated is an off-the-shelf, cell-free, and cost-effective implant that can regenerate either cartilage or subchondral bone. The scaffold allows a 1-step surgical procedure that can be used for osteochondral lesions, OCD, and in some cases osteonecrosis.


  • Conversion of shoulder arthroplasty to reverse implants: clinical and radiological results using a modular system

    by Alessandro Castagna, Marco Delcogliano, Francesca de Caro, Giovanni Ziveri, Mario Borroni, Stefano Gumina, Franco Postacchini, Carlo Felice De Biase

    Revision of a shoulder arthroplasty to a reverse arthroplasty is a highly demanding procedure. The aim of this study is to report the clinical results of hemi and total shoulder prosthesis revisions to reverse implants without removal of the humeral stem, using a modular shoulder replacement system (SMR Lima LTD). We retrospectively reviewed 26 patients who underwent an operation from 2004 to 2009. The patients were divided into two groups: in Group I, 18 patients underwent a revision of hemiarthroplasty implanted for fracture; in Group II, eight patients underwent a revision of anatomical total prosthesis. All patients were evaluated at a mean follow-up of 32.3 (±12.7) months using the Constant score rating scale and by range of motion evaluation, EQ-VAS, X-ray and CT scan. The Constant score of each patient was 47.88 (±5.88) after the revision. The EQ-VAS improved from 40 (±20) to 70 (±10). All patients improved in terms of range of motion. The radiographs and CT scans obtained after revision showed good integration and no signs of loosening of the implant. The mean time of surgery was recorded as 62′ (±8′), with a maximum blood loss of less than 300 ml in all cases. Our study demonstrates that using a full modular system at the time of the first implant allows avoidance of the step to remove the humeral stem and metal back in cases of shoulder prosthesis revision to a reverse prosthesis, resulting in a short operative time, few intraoperative complications and a satisfactory clinical outcome at medium-term follow-up.