Brian S. Biesman
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Brian S. Biesman has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Cara Costner
The Practice of Brian S. Biesman, M.D., Nashville, Tennessee
2 shared publications- Ardalan Minokadeh
Skin Care and Laser Physicians of Beverly Hills, Los Angeles, California
1 shared publication Biesman Brian
1 shared publicationBirgitta Almegård
Head of Medical Affairs Strategy Ax, Galderma , Uppsala , Sweden
1 shared publicationCarolyn Jacob
Dermatologist in private practice , Chicago, Illinois , USA
1 shared publication- Colin Drabe
R&D Merz Aesthetics GmbH, Frankfurt am Main, Germany
1 shared publication
Latest Publications
- Open Access
- 22 October 2026
- Published by Wolters Kluwer Health in Dermatologic Surgery
- Vol. 52 (11S) , e10-e15
Mechanistic Understanding of Tissue-Plane Adaptability in Cohesive Polydensified Matrix Hyaluronic Acid Gels Intense and Volume
BACKGROUND: Hyaluronic acid (HA) gel behavior depends on material properties, injection technique, implantation depth, and tissue biomechanics. Despite similar HA concentrations and overlapping clinical indications, cohesive polydensified matrix (CPM) gels CPM-I and CPM-V exhibit distinct tissue-plane–dependent projection profiles. OBJECTIVE: The aim of this study was to determine whether differences in tissue-plane adaptability between CPM-I and CPM-V are explained by differences in their mechanical behavior under clinically relevant loading conditions. MATERIALS AND METHODS: Standardized 100-μL injections of CPM-I and CPM-V were performed in a synthetic tissue model at subdermal and deep implantation depths. Bolus morphology was quantified by 3-dimensional morphometric analysis. Material behavior was characterized using linear and nonlinear oscillatory rheology, compression testing, and extrusion force measurements. RESULTS: CPM-I demonstrated greater depth-dependent changes than CPM-V. Deep implantation reduced projection height and bolus volume by 12% and 11% for CPM-I versus 6% and 2% for CPM-V. CPM-I also exhibited greater lateral spread, greater strain to flow, and approximately two-fold higher extrusion force, whereas CPM-V demonstrated greater elastic stiffness. Compression end points were similar. CONCLUSION: Despite similar HA concentrations, CPM-I and CPM-V exhibit distinct mechanical and morphometric behaviors. Differences under nonlinear deformation and pressure-driven flow suggest that manufacturing-derived polymer architecture influences tissue-plane adaptability and may support filler selection according to tissue biomechanics.
- 22 October 2026
- Published by Wolters Kluwer Health in Dermatologic Surgery
- Vol. 52 (11S) , e10-e15
Open AccessMechanistic Understanding of Tissue-Plane Adaptability in Cohesive Polydensified Matrix Hyaluronic Acid Gels Intense and Volume
BACKGROUND: Hyaluronic acid (HA) gel behavior depends on material properties, injection technique, implantation depth, and tissue biomechanics. Despite similar HA concentrations and overlapping clinical indications, cohesive polydensified matrix (CPM) gels CPM-I and CPM-V exhibit distinct tissue-plane–dependent projection profiles. OBJECTIVE: The aim of this study was to determine whether differences in tissue-plane adaptability between CPM-I and CPM-V are explained by differences in their mechanical behavior under clinically relevant loading conditions. MATERIALS AND METHODS: Standardized 100-μL injections of CPM-I and CPM-V were performed in a synthetic tissue model at subdermal and deep implantation depths. Bolus morphology was quantified by 3-dimensional morphometric analysis. Material behavior was characterized using linear and nonlinear oscillatory rheology, compression testing, and extrusion force measurements. RESULTS: CPM-I demonstrated greater depth-dependent changes than CPM-V. Deep implantation reduced projection height and bolus volume by 12% and 11% for CPM-I versus 6% and 2% for CPM-V. CPM-I also exhibited greater lateral spread, greater strain to flow, and approximately two-fold higher extrusion force, whereas CPM-V demonstrated greater elastic stiffness. Compression end points were similar. CONCLUSION: Despite similar HA concentrations, CPM-I and CPM-V exhibit distinct mechanical and morphometric behaviors. Differences under nonlinear deformation and pressure-driven flow suggest that manufacturing-derived polymer architecture influences tissue-plane adaptability and may support filler selection according to tissue biomechanics.
- Open Access
- 4 April 2024
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal
- Vol. 44 (9) , 1001-1013
A Multicenter, Randomized, Evaluator-Blinded Study to Examine the Safety and Effectiveness of Hyaluronic Acid Filler in the Correction of Infraorbital Hollows
Hyaluronic acid injections are increasingly used for correction of infraorbital hollows (IOHs). Examination of effectiveness (IOH correction) and safety of Restylane® EyelightTM hyaluronic acid (HAEYE, Galderma, Uppsala, Sweden) injections. Subjects with moderate/severe IOHs, assessed using the Galderma infraorbital hollows scale (GIHS), were randomized to HAEYE injections (via needle/cannula) (Day 1+optional Month-1 touch up) or no-treatment control. Primary endpoint was blinded evaluator-reported Month-3 response, defined as ≥1-point GIHS improvement from baseline (both sides, concurrently). Other endpoints examined investigator-reported aesthetic improvement (GAIS), subject-reported satisfaction (FACE-Q™ satisfaction with outcome; satisfaction questionnaire), and adverse events. Overall, 333 subjects were randomized. Month 3 GIHS responder rate was significantly higher with HAEYE (87.4%) versus control (17.7%; pEYE-needle and HAEYE-cannula groups (p=0.967). HAEYE GAIS responder rate was 87.5–97.7% (Months 3–12). Mean FACE-Q Rasch-transformed scores were 64.3–73.5 (HAEYE) versus 14.1–16.2 (control) through Month 12. Subjects reported looking younger (≥71%) and less tired (≥79%) with reduced under-eye shadows (≥76%) and recovered within 3–5 hours, post-treatment. Efficacy was maintained through Month 12 (63.5% GIHS responders) and through Month 18, after Month-12 retreatment (80.3% GIHS responders; 99.4% GAIS responders; FACE-Q scores: 72.5–72.8). Forty subjects (12.7%) reported typically mild adverse events (4.9% HAEYE-needle; 20.9% HAEYE-cannula). HAEYE treatment was effective in correcting moderate/severe IOHs at the primary endpoint (Month 3). Efficacy was sustained through Month 12 after first treatment for 63.5% and through Month 18 for 80.3% (after one retreatment) with needle or cannula administration. Safety outcomes were reassuring.
- 4 April 2024
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal
- Vol. 44 (9) , 1001-1013
Open AccessA Multicenter, Randomized, Evaluator-Blinded Study to Examine the Safety and Effectiveness of Hyaluronic Acid Filler in the Correction of Infraorbital Hollows
Hyaluronic acid injections are increasingly used for correction of infraorbital hollows (IOHs). Examination of effectiveness (IOH correction) and safety of Restylane® EyelightTM hyaluronic acid (HAEYE, Galderma, Uppsala, Sweden) injections. Subjects with moderate/severe IOHs, assessed using the Galderma infraorbital hollows scale (GIHS), were randomized to HAEYE injections (via needle/cannula) (Day 1+optional Month-1 touch up) or no-treatment control. Primary endpoint was blinded evaluator-reported Month-3 response, defined as ≥1-point GIHS improvement from baseline (both sides, concurrently). Other endpoints examined investigator-reported aesthetic improvement (GAIS), subject-reported satisfaction (FACE-Q™ satisfaction with outcome; satisfaction questionnaire), and adverse events. Overall, 333 subjects were randomized. Month 3 GIHS responder rate was significantly higher with HAEYE (87.4%) versus control (17.7%; pEYE-needle and HAEYE-cannula groups (p=0.967). HAEYE GAIS responder rate was 87.5–97.7% (Months 3–12). Mean FACE-Q Rasch-transformed scores were 64.3–73.5 (HAEYE) versus 14.1–16.2 (control) through Month 12. Subjects reported looking younger (≥71%) and less tired (≥79%) with reduced under-eye shadows (≥76%) and recovered within 3–5 hours, post-treatment. Efficacy was maintained through Month 12 (63.5% GIHS responders) and through Month 18, after Month-12 retreatment (80.3% GIHS responders; 99.4% GAIS responders; FACE-Q scores: 72.5–72.8). Forty subjects (12.7%) reported typically mild adverse events (4.9% HAEYE-needle; 20.9% HAEYE-cannula). HAEYE treatment was effective in correcting moderate/severe IOHs at the primary endpoint (Month 3). Efficacy was sustained through Month 12 after first treatment for 63.5% and through Month 18 for 80.3% (after one retreatment) with needle or cannula administration. Safety outcomes were reassuring.
- Open Access
- 17 October 2022
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 10 (10) , e4547
Dermal Micro-coring for the Treatment of Moderate to Severe Facial Wrinkles
Background: Micro-coring technology (MCT) removes cores of skin without formation of scars, thereby tightening skin and reducing skin wrinkling. The purpose of this study was to evaluate the safety and efficacy of MCT with the dermal micro-coring device for the treatment of facial wrinkles. Methods: This prospective, multicenter clinical trial included fifty-one subjects who underwent MCT treatments of the mid to lower face. The primary study endpoint was change in the Lemperle Wrinkle Severity Scale. Secondary study endpoints were change in Global Aesthetic Improvement Scale (GAIS), participant satisfaction, and evaluation of treatment outcome by an independent review panel. All study endpoints were evaluated at 1, 7, 30, 60, and 150 or 180 days after treatment. Procedure bleeding, pain, and early healing profile were also captured. Results: The mean Lemperle Wrinkle Severity Scale change was 1.3 grades. Improvement in the GAIS was reported for 89.7% (87/97) of treated sites, and average improvement of GAIS was 1.5. Participants reported satisfaction with 85.6% of treatment sites. The independent review panel correctly identified 84.2% of the post-treatment photographs as post-treatment. Procedure bleeding and pain was mild with good healing responses and patient-reported average down time of 3 days. Conclusions: The results of this study demonstrate the safety and efficacy of MCT with the dermal micro-coring device for the treatment of moderate to severe facial wrinkles. MCT led to significant improvement of facial wrinkles with high patient satisfaction and fast recovery time and should be considered in patients who are seeking minimally invasive treatment for wrinkles of the face.
- 17 October 2022
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 10 (10) , e4547
Open AccessDermal Micro-coring for the Treatment of Moderate to Severe Facial Wrinkles
Background: Micro-coring technology (MCT) removes cores of skin without formation of scars, thereby tightening skin and reducing skin wrinkling. The purpose of this study was to evaluate the safety and efficacy of MCT with the dermal micro-coring device for the treatment of facial wrinkles. Methods: This prospective, multicenter clinical trial included fifty-one subjects who underwent MCT treatments of the mid to lower face. The primary study endpoint was change in the Lemperle Wrinkle Severity Scale. Secondary study endpoints were change in Global Aesthetic Improvement Scale (GAIS), participant satisfaction, and evaluation of treatment outcome by an independent review panel. All study endpoints were evaluated at 1, 7, 30, 60, and 150 or 180 days after treatment. Procedure bleeding, pain, and early healing profile were also captured. Results: The mean Lemperle Wrinkle Severity Scale change was 1.3 grades. Improvement in the GAIS was reported for 89.7% (87/97) of treated sites, and average improvement of GAIS was 1.5. Participants reported satisfaction with 85.6% of treatment sites. The independent review panel correctly identified 84.2% of the post-treatment photographs as post-treatment. Procedure bleeding and pain was mild with good healing responses and patient-reported average down time of 3 days. Conclusions: The results of this study demonstrate the safety and efficacy of MCT with the dermal micro-coring device for the treatment of moderate to severe facial wrinkles. MCT led to significant improvement of facial wrinkles with high patient satisfaction and fast recovery time and should be considered in patients who are seeking minimally invasive treatment for wrinkles of the face.
- 20 March 2017
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 49 (4) , 335-340
Evaluation of a transparent perfluorodecalin‐infused patch as an adjunct to laser‐assisted tattoo removal: A pivotal trial
Laser-assisted treatment of tattoos is well recognized to produce opaque epidermal whitening that prevents multiple sequential passes during a single treatment session. The amount of epidermal whitening produced in association with the procedure can be minimized by topical application of perfluorodecalin (PFD), which is an optical clearing agent. This pivotal trial assessed the ability of a transparent PFD-infused patch used in conjunction with a Q-switched nanosecond laser in the treatment of tattoos to permit multiple laser passes during a single 5 minute treatment session in comparison to the number of passes that could be completed using conventional treatment of the tattoo with the laser alone. Thirty subjects (mean age 37 years; 14 males) with predominantly dark blue or black tattoos were enrolled in a split-tattoo trial. One half of each tattoo was treated conventionally, whereas the other half was treated through the PFD patch. Treatments were performed using a nanosecond Q-switched 755-nm Alexandrite laser. The number of treatments performed in a 5-minute time period was quantified for each side of the tattoo (primary effectiveness outcome). Patient-reported pain scores and adverse events (AEs) were also evaluated. Significantly more laser passes could be made on average using the PFD patch compared with treatment using the laser alone (3.7 passes vs. 1.4 passes; P < 0.001). AEs were limited to those expected during laser removal of tattoos. The proportions of subjects with transient edema and erythema were lower in the PFD patch treatment group (36.7% vs. 63.3% and 33.3% vs. 70.0%, respectively); all AEs were transient and resolved quickly. No patient in either group exhibited dyschromia (hypo- or hyperpigmentation) in the treatment area at the 1-month post treatment visit. Additionally, when surveyed at the 1-month follow-up visit, all subjects (30/30) preferred to continue laser-assisted tattoo removal with the PFD patch. An average of 3.7 laser passes were made in a defined 5-minute treatment session when using the transparent PFD-infused patch, which is significantly more than was possible with the laser alone (average of 1.4 passes). Use of the PFD patch was associated with improved tolerability compared with conventional treatment, with subjects experiencing fewer and less severe AEs related to epidermal injury. Lasers Surg. Med.
- 20 March 2017
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 49 (4) , 335-340
Evaluation of a transparent perfluorodecalin‐infused patch as an adjunct to laser‐assisted tattoo removal: A pivotal trial
Laser-assisted treatment of tattoos is well recognized to produce opaque epidermal whitening that prevents multiple sequential passes during a single treatment session. The amount of epidermal whitening produced in association with the procedure can be minimized by topical application of perfluorodecalin (PFD), which is an optical clearing agent. This pivotal trial assessed the ability of a transparent PFD-infused patch used in conjunction with a Q-switched nanosecond laser in the treatment of tattoos to permit multiple laser passes during a single 5 minute treatment session in comparison to the number of passes that could be completed using conventional treatment of the tattoo with the laser alone. Thirty subjects (mean age 37 years; 14 males) with predominantly dark blue or black tattoos were enrolled in a split-tattoo trial. One half of each tattoo was treated conventionally, whereas the other half was treated through the PFD patch. Treatments were performed using a nanosecond Q-switched 755-nm Alexandrite laser. The number of treatments performed in a 5-minute time period was quantified for each side of the tattoo (primary effectiveness outcome). Patient-reported pain scores and adverse events (AEs) were also evaluated. Significantly more laser passes could be made on average using the PFD patch compared with treatment using the laser alone (3.7 passes vs. 1.4 passes; P < 0.001). AEs were limited to those expected during laser removal of tattoos. The proportions of subjects with transient edema and erythema were lower in the PFD patch treatment group (36.7% vs. 63.3% and 33.3% vs. 70.0%, respectively); all AEs were transient and resolved quickly. No patient in either group exhibited dyschromia (hypo- or hyperpigmentation) in the treatment area at the 1-month post treatment visit. Additionally, when surveyed at the 1-month follow-up visit, all subjects (30/30) preferred to continue laser-assisted tattoo removal with the PFD patch. An average of 3.7 laser passes were made in a defined 5-minute treatment session when using the transparent PFD-infused patch, which is significantly more than was possible with the laser alone (average of 1.4 passes). Use of the PFD patch was associated with improved tolerability compared with conventional treatment, with subjects experiencing fewer and less severe AEs related to epidermal injury. Lasers Surg. Med.
- Open Access
- 12 August 2015
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 47 (8) , 613-618
Rapid, high‐fluence multi‐pass q‐switched laser treatment of tattoos with a transparent perfluorodecalin‐infused patch: A pilot study
Perfluorodecalin (PFD) has previously been shown to rapidly dissipate the opaque, white micro-bubble layer formed after exposure of tattoos to Q-switched lasers [1]. The current pilot study was conducted to qualitatively determine if the use of a transparent PFD-infused silicone patch would result in more rapid clearance of tattoos than conventional through-air techniques. Black or dark blue tattoos were divided into two halves in a single-site IRB-approved study with 17 subjects with Fitzpatrick skin types I–III. One half of each tattoo served as its own control and was treated with one pass of a standard Q-switched Alexandrite laser (755 nm). The other half of the tattoo was treated directly through a transparent perfluorodecalin (PFD) infused patch (ON Light Sciences, Dublin, CA). The rapid whitening reduction effect of the Patch routinely allowed three to four laser passes in a total of approximately 5 minutes. Both sides were treated at highest tolerated fluence, but the optical clearing, index-matching, and epidermal protection properties of the PFD Patch allowed significantly higher fluence compared to the control side. Standard photographs were taken at baseline, immediately prior to treatment with the PFD Patch in place, and finally before and after each treatment session. Treatments were administered at 4- to 6-week intervals. In a majority of subjects (11 of 17), tattoos treated through a transparent PFD-infused patch showed more rapid tattoo clearance with higher patient and clinician satisfaction than conventional treatment. In no case did the control side fade faster than the PFD Patch side. No unanticipated adverse events were observed. Rapid multi-pass treatment of tattoos with highest tolerated fluence facilitated by a transparent PFD-infused patch clears tattoos more rapidly than conventional methods. Lasers Surg. Med. 47:613–618, 2015. © 2015 The Authors. Lasers in Surgery and Medicine published by Wiley Periodicals, Inc.
- 12 August 2015
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 47 (8) , 613-618
Open AccessRapid, high‐fluence multi‐pass q‐switched laser treatment of tattoos with a transparent perfluorodecalin‐infused patch: A pilot study
Perfluorodecalin (PFD) has previously been shown to rapidly dissipate the opaque, white micro-bubble layer formed after exposure of tattoos to Q-switched lasers [1]. The current pilot study was conducted to qualitatively determine if the use of a transparent PFD-infused silicone patch would result in more rapid clearance of tattoos than conventional through-air techniques. Black or dark blue tattoos were divided into two halves in a single-site IRB-approved study with 17 subjects with Fitzpatrick skin types I–III. One half of each tattoo served as its own control and was treated with one pass of a standard Q-switched Alexandrite laser (755 nm). The other half of the tattoo was treated directly through a transparent perfluorodecalin (PFD) infused patch (ON Light Sciences, Dublin, CA). The rapid whitening reduction effect of the Patch routinely allowed three to four laser passes in a total of approximately 5 minutes. Both sides were treated at highest tolerated fluence, but the optical clearing, index-matching, and epidermal protection properties of the PFD Patch allowed significantly higher fluence compared to the control side. Standard photographs were taken at baseline, immediately prior to treatment with the PFD Patch in place, and finally before and after each treatment session. Treatments were administered at 4- to 6-week intervals. In a majority of subjects (11 of 17), tattoos treated through a transparent PFD-infused patch showed more rapid tattoo clearance with higher patient and clinician satisfaction than conventional treatment. In no case did the control side fade faster than the PFD Patch side. No unanticipated adverse events were observed. Rapid multi-pass treatment of tattoos with highest tolerated fluence facilitated by a transparent PFD-infused patch clears tattoos more rapidly than conventional methods. Lasers Surg. Med. 47:613–618, 2015. © 2015 The Authors. Lasers in Surgery and Medicine published by Wiley Periodicals, Inc.
- 1 November 2014
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 30 (6) , 529
Re
- 1 November 2014
- Published by Wolters Kluwer Health in Ophthalmic Plastic & Reconstructive Surgery
- Vol. 30 (6) , 529
Re
- Open Access
- 21 July 2014
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 46 (7) , 528-530
Physician alert: Beware of counterfeit medical devices
- 21 July 2014
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 46 (7) , 528-530
Open AccessPhysician alert: Beware of counterfeit medical devices
- 5 June 2013
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 45 (5) , 283-295
Evaluation of a hot-wire hair removal device compared to razor shaving
We describe a blinded, controlled, prospective clinical study of a hot-wire device promoted for hair removal and the reduction or delay of hair regrowth (no!no!, Radiancy, Inc., Orangeburg, NY) compared to a shaving control. Twenty-two subjects were treated by trained clinical staff with the hot-wire device according to its Instructions for Use on the lower leg two times per week for 8 weeks. An adjacent site was shaved with a razor blade on the same schedule to provide a control. Subjects were followed for 3 months after the last treatment to study the durability of the results. Standardized high-resolution photographs were made at baseline, once a week during treatment, and monthly during the post-treatment follow-up period. Micro-tattoos were used to ensure treatments and photographs were reliably made in the same anatomical location from visit to visit. Both active and control sites were shaved prior to baseline and allowed to regrow for a fixed period of time before first treatment to provide a consistent and well-defined baseline hair condition. Quantitative hair counts were made by a third party from the photographs and standard statistical analysis was performed to look for differences between the active and control sites. Visual assessments and quantitative analysis was also performed on the photographs to see if there were any differences in hair thickness (diameter) and hair color between the active and control sites. The results show that shaving and the hot-wire device are indistinguishable in short-term or long-term effect, based on both visual assessment of the photographs and statistical analysis of the hair counts. The control (shaving) had a mean baseline hair count of 79.4, which remained stable (74.8-84.3) during the 8 week-treatment phase and climbed substantially after stopping treatment to 98.8, 100.1, and 104.6 at 1, 2, and 3 months post-treatment, respectively. The active (hot-wire device) had a mean baseline hair count of 86.0 which remained fairly stable (81.7-95.1) during the treatment phase and then climbed substantially after stopping treatment to 104.0, 106.4, and 109.0 at 1, 2, and 3 months post-treatment, respectively. The difference in hair counts between the control and shaving showed that (a) in the treatment phase, shaving was slightly more effective at hair removal than the hot-wire device with weak statistical significance (P < 0.05 at 5 of 7 time points) and (b) in the follow-up phase, shaving and the hot-wire device were statistically indistinguishable (P = 0.252, 0.0972, and 0.230 at 1, 2, and 3 months, respectively). Likewise, the difference in percentage change from baseline in hair counts (which normalizes to baseline values) between the shaving control and hot-wire device is close to zero at every time point (-4.9% to +4.9%) and the t-test P-values are high (0.154< P < 0.890 over all the time points in the study and 0.360 < P < 0.890 during the 1, 2, and 3 month follow-up period), indicating no detectable difference between shaving and the hot-wire. In terms of hair characteristics, no difference in hair color or hair thickness was seen between the shaving control and the hot-wire sites in the treatment or follow-up period. Relative to shaving, the hot-wire (no!no!) device does not produce lessened hair density, decreased hair re-growth rate, greater duration of effect, nor induce changes in hair thickness and color. We conclude that the hot-wire device does not offer any benefit as compared to shaving.
- 5 June 2013
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 45 (5) , 283-295
Evaluation of a hot-wire hair removal device compared to razor shaving
We describe a blinded, controlled, prospective clinical study of a hot-wire device promoted for hair removal and the reduction or delay of hair regrowth (no!no!, Radiancy, Inc., Orangeburg, NY) compared to a shaving control. Twenty-two subjects were treated by trained clinical staff with the hot-wire device according to its Instructions for Use on the lower leg two times per week for 8 weeks. An adjacent site was shaved with a razor blade on the same schedule to provide a control. Subjects were followed for 3 months after the last treatment to study the durability of the results. Standardized high-resolution photographs were made at baseline, once a week during treatment, and monthly during the post-treatment follow-up period. Micro-tattoos were used to ensure treatments and photographs were reliably made in the same anatomical location from visit to visit. Both active and control sites were shaved prior to baseline and allowed to regrow for a fixed period of time before first treatment to provide a consistent and well-defined baseline hair condition. Quantitative hair counts were made by a third party from the photographs and standard statistical analysis was performed to look for differences between the active and control sites. Visual assessments and quantitative analysis was also performed on the photographs to see if there were any differences in hair thickness (diameter) and hair color between the active and control sites. The results show that shaving and the hot-wire device are indistinguishable in short-term or long-term effect, based on both visual assessment of the photographs and statistical analysis of the hair counts. The control (shaving) had a mean baseline hair count of 79.4, which remained stable (74.8-84.3) during the 8 week-treatment phase and climbed substantially after stopping treatment to 98.8, 100.1, and 104.6 at 1, 2, and 3 months post-treatment, respectively. The active (hot-wire device) had a mean baseline hair count of 86.0 which remained fairly stable (81.7-95.1) during the treatment phase and then climbed substantially after stopping treatment to 104.0, 106.4, and 109.0 at 1, 2, and 3 months post-treatment, respectively. The difference in hair counts between the control and shaving showed that (a) in the treatment phase, shaving was slightly more effective at hair removal than the hot-wire device with weak statistical significance (P < 0.05 at 5 of 7 time points) and (b) in the follow-up phase, shaving and the hot-wire device were statistically indistinguishable (P = 0.252, 0.0972, and 0.230 at 1, 2, and 3 months, respectively). Likewise, the difference in percentage change from baseline in hair counts (which normalizes to baseline values) between the shaving control and hot-wire device is close to zero at every time point (-4.9% to +4.9%) and the t-test P-values are high (0.154< P < 0.890 over all the time points in the study and 0.360 < P < 0.890 during the 1, 2, and 3 month follow-up period), indicating no detectable difference between shaving and the hot-wire. In terms of hair characteristics, no difference in hair color or hair thickness was seen between the shaving control and the hot-wire sites in the treatment or follow-up period. Relative to shaving, the hot-wire (no!no!) device does not produce lessened hair density, decreased hair re-growth rate, greater duration of effect, nor induce changes in hair thickness and color. We conclude that the hot-wire device does not offer any benefit as compared to shaving.