Jing Zou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jing Zou has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Ao Chen
BGI Research, Chongqing, China
2 shared publications - Dongyang Xu
BGI-Shenzhen, Shenzhen, 518083, China
2 shared publications - Hanjie Shen
MGI, BGI-Shenzhen, Shenzhen 518083, China; BGI-Shenzhen, Shenzhen 518083, China; China National Genebank, BGI-Shenzhen, Shenzhen 518120, China
2 shared publications - Hanmin Wei
MGI, BGI-Shenzhen, Shenzhen, 518083, China
2 shared publications - Hui Jiang
BGI-Shenzhen
2 shared publications - Jian Wang
BGI-shenzhen, Shenzhen, China
2 shared publications
Latest Publications
- Open Access
- 13 March 2019
- Published by Springer Nature in BMC Genomics
- Vol. 20 (1) , 1-13
Reliable multiplex sequencing with rare index mis-assignment on DNB-based NGS platform
Massively-parallel-sequencing, coupled with sample multiplexing, has made genetic tests broadly affordable. However, intractable index mis-assignments (commonly exceeds 1%) were repeatedly reported on some widely used sequencing platforms. Here, we investigated this quality issue on BGI sequencers using three library preparation methods: whole genome sequencing (WGS) with PCR, PCR-free WGS, and two-step targeted PCR. BGI’s sequencers utilize a unique DNA nanoball (DNB) technology which uses rolling circle replication for DNA-nanoball preparation; this linear amplification is PCR free and can avoid error accumulation. We demonstrated that single index mis-assignment from free indexed oligos occurs at a rate of one in 36 million reads, suggesting virtually no index hopping during DNB creation and arraying. Furthermore, the DNB-based NGS libraries have achieved an unprecedentedly low sample-to-sample mis-assignment rate of 0.0001 to 0.0004% under recommended procedures. Single indexing with DNB technology provides a simple but effective method for sensitive genetic assays with large sample numbers.
- 13 March 2019
- Published by Springer Nature in BMC Genomics
- Vol. 20 (1) , 1-13
Open AccessReliable multiplex sequencing with rare index mis-assignment on DNB-based NGS platform
Massively-parallel-sequencing, coupled with sample multiplexing, has made genetic tests broadly affordable. However, intractable index mis-assignments (commonly exceeds 1%) were repeatedly reported on some widely used sequencing platforms. Here, we investigated this quality issue on BGI sequencers using three library preparation methods: whole genome sequencing (WGS) with PCR, PCR-free WGS, and two-step targeted PCR. BGI’s sequencers utilize a unique DNA nanoball (DNB) technology which uses rolling circle replication for DNA-nanoball preparation; this linear amplification is PCR free and can avoid error accumulation. We demonstrated that single index mis-assignment from free indexed oligos occurs at a rate of one in 36 million reads, suggesting virtually no index hopping during DNB creation and arraying. Furthermore, the DNB-based NGS libraries have achieved an unprecedentedly low sample-to-sample mis-assignment rate of 0.0001 to 0.0004% under recommended procedures. Single indexing with DNB technology provides a simple but effective method for sensitive genetic assays with large sample numbers.
- Open Access
Reliable Multiplex Sequencing with Rare Index Mis-Assignment on DNB-Based NGS Platform
Background: Massively-parallel-sequencing, coupled with sample multiplexing, has made genetic tests broadly affordable. However, intractable index mis-assignments (commonly exceeds 1%) were repeatedly reported on some widely used sequencing platforms. Results: Here, we investigated this quality issue on BGI sequencers using three library preparation methods: whole genome sequencing (WGS) with PCR, PCR-free WGS, and two-step targeted PCR. BGI’s sequencers utilize a unique DNB technology which uses rolling circle replication for DNA-nanoball preparation; this linear amplification is PCR free and can avoid error accumulation. We demonstrated that single index mis-assignment from free indexed oligos occurs at a rate of one in 36 million reads, suggesting virtually no index hopping during DNB creation and arraying. Furthermore, the DNB-based NGS libraries have achieved an unprecedentedly low sample-to-sample mis-assignment rate of 0.0001% to 0.0004% under recommended procedures. Conclusions: Single indexing with DNB technology provides a simple but effective method for sensitive genetic assays with large sample numbers.
Open AccessReliable Multiplex Sequencing with Rare Index Mis-Assignment on DNB-Based NGS Platform
Background: Massively-parallel-sequencing, coupled with sample multiplexing, has made genetic tests broadly affordable. However, intractable index mis-assignments (commonly exceeds 1%) were repeatedly reported on some widely used sequencing platforms. Results: Here, we investigated this quality issue on BGI sequencers using three library preparation methods: whole genome sequencing (WGS) with PCR, PCR-free WGS, and two-step targeted PCR. BGI’s sequencers utilize a unique DNB technology which uses rolling circle replication for DNA-nanoball preparation; this linear amplification is PCR free and can avoid error accumulation. We demonstrated that single index mis-assignment from free indexed oligos occurs at a rate of one in 36 million reads, suggesting virtually no index hopping during DNB creation and arraying. Furthermore, the DNB-based NGS libraries have achieved an unprecedentedly low sample-to-sample mis-assignment rate of 0.0001% to 0.0004% under recommended procedures. Conclusions: Single indexing with DNB technology provides a simple but effective method for sensitive genetic assays with large sample numbers.
- Open Access
- 12 July 2014
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 14 (1) , 388
HPV genotypes and associated cervical cytological abnormalities in women from the Pearl River Delta region of Guangdong province, China: a cross-sectional study
It is important to understand the specific HPV genotype distribution in screen-detected lesions. HPV Genotype is helpful for separating HPV-positive women at greater risk of cancer from those who can regress spontaneously and for preventing cervical cancer at early stage. The aim of this study was to investigate the high-risk HPV genotype distribution among cervical cytology abnormality in Pearl River Delta Region, Southern China 5585 HPV-infected women were screened from 77069 women in Pearl River Delta Region. Information was obtained from 3226 screened subjects through questionnaires and personal interviews. Exfoliated cervical cells were collected by doctors for HPV test with MassARRAY (Sequenom, Sandiego, CA) technique based on the matrix-assisted laser desorption/ionization time-of flight (MALDI-TOF) mass spectrometry (MS). The ThinPrep cytology test was performed to screen for cervical cancer. Unconditional logistic was used to determine the most common HPV carcinogenic types. Of the 3226 HPV-positive samples tested, 1744 (54.1%) with normal cervical cytology, 1482 (45.9%) with abnormal cytology. The five most common HPV types in this study were HPV16 (20.2%), HPV52 (17.1%), HPV58 (13.2%), HPV18 (9.5%), HPV6 (7.6%). Overall, HPV16 (OR = 10.5, 95% CI: 3.7 ~ 29.6), HPV33 (OR = 9.1, 95% CI: 2.8 ~ 29.2), HPV58 (OR = 6.3, 95% CI: 2.1 ~ 18.6), HPV31 (OR = 4.5, 95% CI: 1.3 ~ 15.5), multiple genotype infection (OR = 3.0, 95% CI: 1.7 ~ 14.7), especially HPV16 and HPV33, increased the risk of cytology abnormalities. HPV16, HPV31, HPV33, HPV58, and multiple HPV genotype infection increased the risk of cytology abnormalities in Pearl River Delta Region and might be useful for the screening, preventing, treating, and monitoring of pre-cancer lesions in southern China.
- 12 July 2014
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 14 (1) , 388
Open AccessHPV genotypes and associated cervical cytological abnormalities in women from the Pearl River Delta region of Guangdong province, China: a cross-sectional study
It is important to understand the specific HPV genotype distribution in screen-detected lesions. HPV Genotype is helpful for separating HPV-positive women at greater risk of cancer from those who can regress spontaneously and for preventing cervical cancer at early stage. The aim of this study was to investigate the high-risk HPV genotype distribution among cervical cytology abnormality in Pearl River Delta Region, Southern China 5585 HPV-infected women were screened from 77069 women in Pearl River Delta Region. Information was obtained from 3226 screened subjects through questionnaires and personal interviews. Exfoliated cervical cells were collected by doctors for HPV test with MassARRAY (Sequenom, Sandiego, CA) technique based on the matrix-assisted laser desorption/ionization time-of flight (MALDI-TOF) mass spectrometry (MS). The ThinPrep cytology test was performed to screen for cervical cancer. Unconditional logistic was used to determine the most common HPV carcinogenic types. Of the 3226 HPV-positive samples tested, 1744 (54.1%) with normal cervical cytology, 1482 (45.9%) with abnormal cytology. The five most common HPV types in this study were HPV16 (20.2%), HPV52 (17.1%), HPV58 (13.2%), HPV18 (9.5%), HPV6 (7.6%). Overall, HPV16 (OR = 10.5, 95% CI: 3.7 ~ 29.6), HPV33 (OR = 9.1, 95% CI: 2.8 ~ 29.2), HPV58 (OR = 6.3, 95% CI: 2.1 ~ 18.6), HPV31 (OR = 4.5, 95% CI: 1.3 ~ 15.5), multiple genotype infection (OR = 3.0, 95% CI: 1.7 ~ 14.7), especially HPV16 and HPV33, increased the risk of cytology abnormalities. HPV16, HPV31, HPV33, HPV58, and multiple HPV genotype infection increased the risk of cytology abnormalities in Pearl River Delta Region and might be useful for the screening, preventing, treating, and monitoring of pre-cancer lesions in southern China.
- 1 May 2013
- Published by Elsevier in Gynecologic Oncology
- Vol. 129 (2) , 318-323
The Peru Cervical Cancer Prevention Study (PERCAPS): The technology to make screening accessible
- 1 May 2013
- Published by Elsevier in Gynecologic Oncology
- Vol. 129 (2) , 318-323
The Peru Cervical Cancer Prevention Study (PERCAPS): The technology to make screening accessible