DRDaniele Romanini
Daniele Romanini
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniele Romanini has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Alain Campargue
1 shared publicationDidier Mondelain
1 shared publication- Erik R. Th. Kerstel
Univ. Grenoble Alpes, CNRS, LIPhy, 38000 Grenoble, France
1 shared publication Guillaume Méjean
Univ. Grenoble 1/CNRS
1 shared publication- Irene Ventrillard-Courtillot
LIPhy UMR 5588, Univ. Grenoble 1/CNRS, Grenoble, France
1 shared publication Irène Ventrillard
Univ. Grenoble 1/CNRS
1 shared publication
Latest Publications
- 1 January 2014
- Published by Springer Nature
- p. 1-60
Introduction to Cavity Enhanced Absorption Spectroscopy
- 1 January 2014
- Published by Springer Nature
- p. 1-60
Introduction to Cavity Enhanced Absorption Spectroscopy
- 14 September 2010
- Published by American Physical Society (APS) in Physical Review A
- Vol. 82 (3)
Shot-noise-limited measurement of sub–parts-per-trillion birefringence phase shift in a high-finesse cavity
We report on a promising approach to high-sensitivity anisotropy measurements using a high-finesse cavity locked by optical feedback to a diode laser. We provide a simple and effective way to decouple the weak anisotropy of interest from the inherent mirror’s birefringence whose drift may be identified as the key limiting parameter in cavity-based techniques. We demonstrate a shot-noise-limited phase shift resolution previously inaccessible in an optical cavity, readily achieving the state-of-the-art level of rad. DOI: http://dx.doi.org/10.1103/PhysRevA.82.031803 © 2010 The American Physical Society- 14 September 2010
- Published by American Physical Society (APS) in Physical Review A
- Vol. 82 (3)
Shot-noise-limited measurement of sub–parts-per-trillion birefringence phase shift in a high-finesse cavity
We report on a promising approach to high-sensitivity anisotropy measurements using a high-finesse cavity locked by optical feedback to a diode laser. We provide a simple and effective way to decouple the weak anisotropy of interest from the inherent mirror’s birefringence whose drift may be identified as the key limiting parameter in cavity-based techniques. We demonstrate a shot-noise-limited phase shift resolution previously inaccessible in an optical cavity, readily achieving the state-of-the-art level of rad. DOI: http://dx.doi.org/10.1103/PhysRevA.82.031803 © 2010 The American Physical Society