    Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

    by Laryssa A Korduba, Aaron Essner, Robert Pivec, Perry Lancin, Michael A Mont, Aiguo Wang, Ronald E Delanois

    The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if cups are oriented at more than 40° of abduction.


  • Wear of ultra-high molecular weight polyethylene moving along a circular path in a hip simulator

    by Aiguo Wang, Reginald Lee, Lizeth Herrera, Laryssa Korduba


    • 1 October 2010
      • Vol. 20, 303-8

    Metal-on-metal bearings: the problem is edge-loading wear.

    by Reginald K Lee, Jason Longaray, Aaron Essner, Aiguo Wang

    Metal-on-metal bearings are promoted as a low wear bearing alternative to traditional hip replacement bearings. While most in vitro studies support this, recent clinical reviews have found a significant number of early revisions in some designs of metal-on-metal bearings related to wear. Metal-on-metal bearings exhibit a bi-phasic wear pattern with high initial wear that generally settles down to low steady state wear. Previous publications from the authors have found that steady state wear occurs due to the formation of a critical conforming contact area. This contact area was found to be surprisingly constant regardless of bearing size, clearance, or even contact mode. The authors hypothesized that steady state wear may never be reached if formation of this critical conforming contact area is disrupted. Several hip simulator tests were performed to assess the wear performance of generic metal-on-metal samples at various angles of inclination. Three-dimensional modeling was performed on the generic bearing design as well as typical resurfacing and hemispherical bearing designs including various sizes and clearance ranges. Simulator results support the hypotheses, and wear rates were linear or accelerating when the critical contact area size could not be achieved due to its proximity to the rim of the bearing. Modeling studies show a correlation between bearing size and design and the maximum inclination angle allowed to reach steady state conditions. Smaller bearing size and shallower cup designs were found to reduce the maximum safe inclination angle and this corresponds to clinical observation of increased failure rates in these bearings. This simple method for assessing runaway wear risk can be utilized in the design of more robust and forgiving metal-on-metal bearings.


  • Tribology of Metal-on-Metal Bearings at High Inclination Angles

    by Reginald Lee, Aiguo Wang, Aaron Essner, Shirong Ge

    • 28 June 2003
      • Vol. 61, 17-26

    Comparison of the properties of annealed crosslinked (Crossfire) and conventional polyethylene as hip bearing materials.

    by Steve M Kurtz, Michael Manley, Aiguo Wang, Scott Taylor, John Dumbleton

    In 1998, orthopaedic manufacturers started to introduce highly crosslinked ultra-high molecular weight polyethylene (UHMWPE) for total hip replacement bearings. Today's highly-crosslinked UHMWPEs materials are irradiation processed with a total dose ranging between 50 and 105 kGy, depending upon the manufacturer. Each manufacturer has adopted a different route for producing their highly crosslinked UHMWPE that includes a combination of three important processing steps: an irradiation step, an intra or post-irradiation thermal processing step, and a sterilization step. This paper reviews the choices available to an implant designer when developing a highly-crosslinked UHMWPE as an orthopaedic bearing material. We suggest that the application of annealing rather than re-melting in the thermal processing step allows the retention of important mechanical properties in the finished material. This approach will be illustrated with test data on Crossfire (Stryker Howmedica Osteonics, Mahwah, NJ), an annealed, highly-crosslinked UHMWPE developed specifically for total hip replacements. We compare the physical, mechanical, and wear properties of Crossfire with that of conventional (N2-Vac) UHMWPE and with materials produced using published melt irradiation technology. At the short term (2 and 3 years) the results demonstrated through clinical follow-up, clinical results for Crossfire, are encouraging. Longer follow-up is necessary to confirm the benefits to patients from reduction of debris released from the articulation.