Williams Estève
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Williams Estève has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Eddy Langlois
Laboratoire de Chimie Analytique Organique, Département Métrologie des Polluants , Institut National de Recherche et de Sécurité (INRS) , Vandoeuvre , France
2 shared publications- Marie-Thérèse Lecler
Department of Process Engineering, INRS (French National Research and Safety Institute for the Prevention of Occupational Accidents and Diseases), CS 60027, 54519 Vandoeuvre-lès-Nancy, France
2 shared publications - Aurélie Martin Remy
Department of Toxicology and Biomonitoring, INRS (French National Research and Safety Institute for the Prevention of Occupational Accidents and Diseases), CS 60027, 54519 Vandoeuvre-lès-Nancy, France
1 shared publication - Baninia Habchi
Department of Toxicology and Biomonitoring, INRS -French National Research and Safety Institute for the Prevention of Occupational Accidents and Diseases, Vandœuvre-lès-Nancy, France
1 shared publication Christel Ravera
Laboratoire de Chimie Analytique Organique, Département Métrologie des Polluants , Institut National de Recherche et de Sécurité (INRS) , Vandoeuvre , France
1 shared publication- Claude Emond
Department of Occupational and Environmental Health, School of Public Health, Université de Montréal, Montréal, QC H3N 1X9, Canada
1 shared publication
Latest Publications
- Open Access
Temporal Variability of Urinary Organophosphate Flame Retardant Metabolites Among E-Waste Workers in France: A Pilot Study to Inform Occupational Biomonitoring Sampling Design
Workers in the e-waste industry are exposed to chemical hazards, including organophosphate esters (OPEs) used as flame retardants (FRs). Assessing exposure through spot urine metabolite analysis is challenging due to limited knowledge of the toxicokinetics and urinary excretion patterns of OPEs. This pilot study investigates the temporal variability of seven organophosphate flame retardants (OPFRs) in urine samples from e-waste workers over five workdays to identify the most representative spot urine sample for accurately assessing occupational exposure. Six exposed workers provided urine samples from the first shift of the working week to the morning after the last workday. Seven metabolites, (bis(2-chloroethyl) phosphate (BCEP), diphenyl phosphate (DPHP), di-o-cresyl phosphate (DoCP), di-m-cresyl phosphate (DmCP), di-p-cresyl phosphate (DpCP), bis(1,3-dichloro-2-propyl) phosphate (BDCPP) and bis-(1-chloro-2-propyl) phosphate (BCPP)), were analyzed using liquid chromatography-mass spectrometry. DmCP + DpCP showed weekly increases and fair to good intraclass correlation coefficient (ICC), indicating moderate temporal variability across days. Conversely, DPHP and BCEP showed rapid decreases and lower ICC, suggesting higher intra-day variability. A grouping approach based on collection time and workday showed that the suitable spot urine is 2–5 h delayed post-shift for BCEP and DPHP, whereas the end of the workweek is the most appropriate time for DmCP + DpCP. This pilot study provides preliminary information on temporal variability to inform sampling design. This approach could be extended to a broader range of FRs, thereby enhancing the efficiency and accuracy of occupational biomonitoring.
Open AccessTemporal Variability of Urinary Organophosphate Flame Retardant Metabolites Among E-Waste Workers in France: A Pilot Study to Inform Occupational Biomonitoring Sampling Design
Workers in the e-waste industry are exposed to chemical hazards, including organophosphate esters (OPEs) used as flame retardants (FRs). Assessing exposure through spot urine metabolite analysis is challenging due to limited knowledge of the toxicokinetics and urinary excretion patterns of OPEs. This pilot study investigates the temporal variability of seven organophosphate flame retardants (OPFRs) in urine samples from e-waste workers over five workdays to identify the most representative spot urine sample for accurately assessing occupational exposure. Six exposed workers provided urine samples from the first shift of the working week to the morning after the last workday. Seven metabolites, (bis(2-chloroethyl) phosphate (BCEP), diphenyl phosphate (DPHP), di-o-cresyl phosphate (DoCP), di-m-cresyl phosphate (DmCP), di-p-cresyl phosphate (DpCP), bis(1,3-dichloro-2-propyl) phosphate (BDCPP) and bis-(1-chloro-2-propyl) phosphate (BCPP)), were analyzed using liquid chromatography-mass spectrometry. DmCP + DpCP showed weekly increases and fair to good intraclass correlation coefficient (ICC), indicating moderate temporal variability across days. Conversely, DPHP and BCEP showed rapid decreases and lower ICC, suggesting higher intra-day variability. A grouping approach based on collection time and workday showed that the suitable spot urine is 2–5 h delayed post-shift for BCEP and DPHP, whereas the end of the workweek is the most appropriate time for DmCP + DpCP. This pilot study provides preliminary information on temporal variability to inform sampling design. This approach could be extended to a broader range of FRs, thereby enhancing the efficiency and accuracy of occupational biomonitoring.
- Open Access
- 28 May 2026
- Published by Elsevier in Chemosphere
- Vol. 407, 144972
Photodegradation of TBBPA/ABS materials and exposure to brominated residues during WEEE recycling
- 28 May 2026
- Published by Elsevier in Chemosphere
- Vol. 407, 144972
Open AccessPhotodegradation of TBBPA/ABS materials and exposure to brominated residues during WEEE recycling
- 8 August 2013
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 10 (9) , 505-518
Developing a New Simplified Method to Determine Diffusive Uptake Rates of Volatile Organic Compounds in Workplaces Based on a Fractional Factorial Designs Approach
Exposure to organic vapors in the workplace is a source of occupational risk. Admissible exposure levels are tightly regulated and must be closely monitored. However, the complexity and slowness of the existing complete protocols to determine diffusive uptake rates through passive sampling have limited the use of this tool despite obvious advantages. In this study, we experimentally validate two simplified protocols to determine diffusive uptake rates with passive sampling. The proposed 26-3 and 26-2 fractional factorial designs were validated for toluene sampling using a (Gas Adsorbent Badge for Individual Exposure) GABIE-activated charcoal sampler in a controlled atmosphere. The uptake rate for this sampler had been determined previously using a full protocol. The uptake rates for all three protocols were similar, indicating that the proposed new designs can be substituted for classical full protocols. After validation of our protocols, uptake rates for new substances used as fuel additives (methyl and ethyl tert-butyl ethers, MTBE and ETBE) were determined on the same sampler using the 26-2 design. In these experiments, temperature appears to have a non-negligible influence on the uptake rates measured for these compounds. With some precautions of usage (ambient temperature below a determined limit temperature or at least exposure time ≥4 h) and storage (storage temperature = 4°C) of the sampler, the experimental diffusive uptake rates determined by this method can be used with good confidence. Field experiments confirmed the experimental results, showing good agreement between active and passive sampling using the experimentally determined uptake rates.
- 8 August 2013
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 10 (9) , 505-518
Developing a New Simplified Method to Determine Diffusive Uptake Rates of Volatile Organic Compounds in Workplaces Based on a Fractional Factorial Designs Approach
Exposure to organic vapors in the workplace is a source of occupational risk. Admissible exposure levels are tightly regulated and must be closely monitored. However, the complexity and slowness of the existing complete protocols to determine diffusive uptake rates through passive sampling have limited the use of this tool despite obvious advantages. In this study, we experimentally validate two simplified protocols to determine diffusive uptake rates with passive sampling. The proposed 26-3 and 26-2 fractional factorial designs were validated for toluene sampling using a (Gas Adsorbent Badge for Individual Exposure) GABIE-activated charcoal sampler in a controlled atmosphere. The uptake rate for this sampler had been determined previously using a full protocol. The uptake rates for all three protocols were similar, indicating that the proposed new designs can be substituted for classical full protocols. After validation of our protocols, uptake rates for new substances used as fuel additives (methyl and ethyl tert-butyl ethers, MTBE and ETBE) were determined on the same sampler using the 26-2 design. In these experiments, temperature appears to have a non-negligible influence on the uptake rates measured for these compounds. With some precautions of usage (ambient temperature below a determined limit temperature or at least exposure time ≥4 h) and storage (storage temperature = 4°C) of the sampler, the experimental diffusive uptake rates determined by this method can be used with good confidence. Field experiments confirmed the experimental results, showing good agreement between active and passive sampling using the experimentally determined uptake rates.
- 18 April 2012
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 4 (7) , 2054-2061
Evaluation of an alternate microwave-assisted thermal desorption technique: compatibility with charcoal active and passive sampling for BTX exposure assessment in workplace atmospheres
A microwave-assisted alternate thermal desorption technique has been optimized and discussed concerning the compatibility with the occupational exposure assessment of organic pollution both by activated charcoal active and passive sampling. This technique applied to aromatic compounds (benzene, toluene and m-xylene) has shown a good efficiency by pumped sampling directly made on the ceramic desorption tubes. The optimal desorption recovery has been obtained with 50 mg of activated charcoal previously thermally treated, and when sampling was performed at low flow rates (3). But, the low quantity of activated charcoal in the ceramic sampling/desorption tubes, and consequently the limited trapping capacity, could be an issue especially in highly polluted areas. The passive sampling technique, whose diffusive sampling flow rates are usually smaller than regular active sampling ones, seemed to be a better alternative in that case. A preliminary evaluation of the diffusion sampling rates Ui by the direct use of the ceramic desorption tubes as passive samplers has been undertaken using a controlled gas test facility (Ubenzene = 0.13 cm3 min−1, Utoluene = 0.11 cm3 min−1, Uxylene = 0.11 cm3 min−1). The microwave thermal desorption technique, coupled to passive sampling, could be an appropriate and efficient analytical method for the assessment of workplace organic pollutions.
- 18 April 2012
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 4 (7) , 2054-2061
Evaluation of an alternate microwave-assisted thermal desorption technique: compatibility with charcoal active and passive sampling for BTX exposure assessment in workplace atmospheres
A microwave-assisted alternate thermal desorption technique has been optimized and discussed concerning the compatibility with the occupational exposure assessment of organic pollution both by activated charcoal active and passive sampling. This technique applied to aromatic compounds (benzene, toluene and m-xylene) has shown a good efficiency by pumped sampling directly made on the ceramic desorption tubes. The optimal desorption recovery has been obtained with 50 mg of activated charcoal previously thermally treated, and when sampling was performed at low flow rates (3). But, the low quantity of activated charcoal in the ceramic sampling/desorption tubes, and consequently the limited trapping capacity, could be an issue especially in highly polluted areas. The passive sampling technique, whose diffusive sampling flow rates are usually smaller than regular active sampling ones, seemed to be a better alternative in that case. A preliminary evaluation of the diffusion sampling rates Ui by the direct use of the ceramic desorption tubes as passive samplers has been undertaken using a controlled gas test facility (Ubenzene = 0.13 cm3 min−1, Utoluene = 0.11 cm3 min−1, Uxylene = 0.11 cm3 min−1). The microwave thermal desorption technique, coupled to passive sampling, could be an appropriate and efficient analytical method for the assessment of workplace organic pollutions.