MMMariano Makara

Mariano Makara

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mariano Makara has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Computed Tomography-Derived Occipital–Coccygeal Length and Ilium Wing Distance Correlates with Skin to Epidural and Intrathecal Depths in Dogs

    by Tsim Christopher Sun, Mariano Makara, Fernando Martinez-Taboada

    The current clinical techniques for neuraxial needle placement in dogs are predominantly blind without prior knowledge of the depth required to reach the desired space. This study investigated the correlation and defined the relationship between easily obtainable external landmark variables in the dog; occipital–coccygeal length (OCL) and ilium wings distance (IWD), with the skin to epidural and intrathecal space distances using computed tomography (CT). The CT images of 86 dogs of different breeds were examined in this retrospective observational study. Images of dogs in sternal recumbency were optimized to the sagittal view. The distances between the skin and lumbosacral epidural space (LSE) and skin to sacrococcygeal space (SCE) were measured to the ligamentum flavum surrogate (LFS) line. The distance between the skin and the intrathecal space (ITS) was measured from the skin to the vertebral canal at the interlumbar (L5–L6) space. Measurements of the IWD and OCL were performed on dorsal and scout views, respectively. Linear regression equations and Pearson’s correlation coefficients were calculated between variables. Data were reported as mean (standard deviation). Significance was set as alpha < 0.05. After exclusion of four dogs, 82 CT scans were included. The depths were LSE 45 (15) mm, SCE 23 (10) mm, and ITS 50 (15) mm. There was a moderate correlation between OCL with LSE (=14.2 + OCL * 0.05 (r = 0.59, p < 0.0001)), and a strong correlation with ITS (=11.4 + OCL * 0.07 (r = 0.76, p < 0.0001)), while a very weak correlation was found with SCE (=14.0 + OCL * 0.02 (r = 0.27, p < 0.0584)). Similarly, with IWD, there was a moderate correlation with LSE (=10.8 + IWD * 0.56 (r = 0.61, p < 0.0001)), and strong correlation with ITS (=9.2 + IWD * 0.67 (r = 0.75, p < 0.0001)), while a weak correlation was found with SCE (=11.2 + IWD * 0.2 (r = 0.32, p < 0.0033)). Mathematical formulae derived from the multiple regression showed that the body condition score (BCS) improved the relationship between IWD and OCL and the LSE, SCE and ITS, while the addition of body weight was associated with multicollinearity. Further studies are required to determine the accuracy of the algorithms to demonstrate their ability for prediction in a clinical setting.


  • Effect of body position and time on quantitative computed tomographic measurements of lung volume and attenuation in healthy anesthetized cats

    by Timothy S. Foo, Joanna L. Pilton, Evelyn J. Hall, Fernando Martinez-Taboada, Mariano Makara

    OBJECTIVE To quantify the effect of time and recumbency on CT measurements of lung volume and attenuation in healthy cats under general anesthesia. ANIMALS 8 healthy research cats. PROCEDURES Anesthetized cats were positioned in sternal recumbency for 20 minutes and then in left, right, and left lateral recumbency (40 minutes/position). Expiratory helical CT scan of the thorax was performed at 0 and 20 minutes in sternal recumbency and at 0, 5, 10, 20, 30, and 40 minutes in each lateral recumbent position. For each lung, CT measurements of lung volume and attenuation and the extent of lung areas that were hyperaerated (−1,000 to −901 Hounsfield units [HU]), normoaerated (−900 to −501 HU), poorly aerated (−500 to −101 HU), or nonaerated (−100 to +100 HU [indicative of atelectasis]) were determined with a semiautomatic threshold-based technique. A restricted maximum likelihood analysis was performed. RESULTS In lateral recumbency, the dependent lung had significantly greater attenuation and a lower volume than the nondependent lung. Within the dependent lung, there was a significantly higher percentage of poorly aerated lung tissue, compared with that in the nondependent lung. These changes were detected immediately after positioning the cats in lateral recumbency and remained static with no further significant time-related change. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that once anesthetized healthy cats were positioned in lateral recumbency, the dependent lung lobes underwent a rapid reduction in lung volume and increase in lung attenuation that did not progress over time, predominantly attributable to an increase in poorly aerated lung tissue.


  • Open Access

    Effect of proximal translation of the osteotomized tibial tuberosity during tibial tuberosity advancement on patellar position and patellar ligament angle

    by Jack D. Neville-Towle, Mariano Makara, Kenneth A. Johnson, Katja Voss

    Cranial cruciate ligament insufficiency is a common orthopaedic problem in canine patients. This cadaveric and radiographic study was performed with the aim of determining the effect of proximal translation of the tibial tuberosity during tibial tuberosity advancement (TTA) on patellar position (PP) and patellar ligament angle (PLA). Disarticulated left hind limb specimens harvested from medium to large breed canine cadavers (n = 6) were used for this study. Limbs were mounted to Plexiglass sheets with the stifle joint fixed in 135° of extension. The quadriceps mechanism was mimicked using an elastic band. Medio-lateral radiographs were obtained pre-osteotomy, after performing TTA without proximal translation of the tibial tuberosity, and after proximal translation of the tibial tuberosity by 3mm and 6mm. Radiographs were blinded to the observer for distance of tibial tuberosity proximalization following radiograph acquisition. Three independent observers recorded PP and PLA (tibial plateau method and common tangent method). Comparisons were made between the stages of proximalization using repeated measures ANOVA. Patellar position was found to be significantly more distal than pre-osteotomy, if the tibial tuberosity was not translated proximally (P = 0.001) and if it was translated proximally by 3mm (P = 0.005). The difference between pre-osteotomy PP and 6mm proximalization was not significant. The PLA was significantly larger if the tibial tuberosity was not translated proximally compared to tibial tuberosity proximalization of 6mm using the tibial plateau and the common tangent methods (P = 0.006 and P = 0.015 respectively). Proximalizing the tibial tuberosity during TTA helps in maintaining vertical position of the patella in the patellar groove. Proximalization of the tibial tuberosity reduces PLA when compared to TTA without tibial tuberosity proximalization.


  • Estimation of time to peak contrast enhancement of the aorta and liver for dual-phase computed tomography on the basis of contrast medium arrival time, injection duration, and injection technique in dogs

    by Jennifer Chau, Alex C. Young, Navneet Dhand, Mariano A. Makara

    OBJECTIVE To evaluate the accuracy of estimating time to peak enhancement (TPE) of the aorta and liver parenchyma on the basis of contrast medium arrival time in the aorta, injection duration, and injection technique in dogs. ANIMALS 18 dogs of specific body weight categories (≥ 2 dogs/category) with no liver abnormalities detected via CT. PROCEDURES Dogs were randomly assigned within weight categories to receive contrast medium IV at a fixed injection rate (5 mL/s) or fixed injection duration (20 seconds). Time–contrast attenuation curves were generated from dynamic CT scans acquired at the hepatic hilus. Data collected for contrast medium arrival time and injection duration were used to estimate TPEs of the aorta and liver, and results were compared with the observed TPEs for the aorta and liver. RESULTS Contrast medium arrival time, injection duration, and injection technique were significantly associated with observed values for aortic TPE and explained 96.1% of variation in TPE. For the fixed rate technique, the regression equation for estimating aortic TPE was 0.8 × (injection duration + contrast medium arrival time) + 1.6. For the fixed duration technique, the regression equation changed by only the constant (–2.6). However, the hepatic TPE estimated from the 3 predictor variables was not significantly different from the mean of observed TPEs. CONCLUSIONS AND CLINICAL RELEVANCE Aortic TPE could be accurately estimated from contrast medium arrival time, injection duration, and injection technique in dogs with apparently healthy livers. The regression equations derived from this relationship can be used to improve the efficiency of dual-phase CT of the liver in dogs.


  • EFFECTS OF TWO CONTRAST INJECTION PROTOCOLS ON FELINE AORTIC AND HEPATIC ENHANCEMENT USING DYNAMIC COMPUTED TOMOGRAPHY

    by Mariano Makara, Jennifer Chau, Evelyn Hall, Heide Kloeppel, Juan Podadera, Vanessa Barrs

    This prospective study compared aortic and hepatic enhancement achieved using a contrast injection protocol with a fixed rate of 5 ml/s vs. that achieved using a protocol with fixed injection duration of 20 s in eight cats. Cats were assigned into two groups (Group 1, rate 5 ml/s; Group 2, duration 20 s). The dose of contrast was the same in both groups (740 mgI/kg). Regions of interest (ROI) were drawn in the aorta and liver for transverse scans acquired at the hepatic hilus. Time to peak aortic enhancement occurred significantly earlier in Group 1 (M= 11s,SD= 1.63) than in Group 2 (M= 25.5 s,SD= 2.51). Peak aortic enhancement was significantly higher in Group 1 (M= 1906.51 HU,SD= 368.64) than in Group 2 (M= 745.08 HU,SD= 201.84). Duration of aortic enhancement equal to or above 300 HU was statistically longer in Group 2 (M= 24.5 s,SD= 8.39) than in Group 1 (M= 10 s,SD= 1.63). There were no significant differences in time to peak liver enhancement, peak liver enhancement, or duration of hepatic arterial phase between groups. Findings supported the hypothesis that longer injection duration results in a broader bolus geometry with a longer time to peak and a lower peak aortic enhancement in cat. This strong influence of injection duration on timing of aortic enhancement may help future users optimize protocols for CT angiography of the aorta and multiphasic evaluation of the liver, pancreas, and small intestine.


  • EFFECTS OF STIFLE FLEXION ANGLE AND SCAN PLANE ON VISIBILITY OF THE NORMAL CANINE CRANIAL CRUCIATE LIGAMENT USING LOW‐FIELD MAGNETIC RESONANCE IMAGING

    by Juan Podadera, Patrick Gavin, Travis Saveraid, Evelyn Hall, Jennifer Chau, Mariano Makara

    Low‐field magnetic resonance imaging (MRI) is commonly used to evaluate dogs with suspected cranial cruciate ligament injury; however, effects of stifle positioning and scan plane on visualization of the ligament are incompletely understood. Six stifle joints (one pilot, five test) were collected from dogs that were scheduled for euthanasia due to reasons unrelated to the stifle joint. Each stifle joint was scanned in three angles of flexion (90°, 135°, 145°) and eight scan planes (three dorsal, three axial, two sagittal), using the same low‐field MRI scanner and T2‐weighted fast spin echo scan protocol. Two experienced observers who were unaware of scan technique independently scored visualization of the cranial cruciate ligament in each scan using a scale of 0–3. Visualization score rank sums were higher when the stifle was flexed at 90° compared to 145°, regardless of the scan plane. Visualization scores for the cranial cruciate ligament in the dorsal (H (2) = 19.620,P= 0.000), axial (H (2) = 14.633,P= 0.001), and sagittal (H (2) = 8.143,P= 0.017) planes were significantly affected by the angle of stifle flexion. Post hoc analysis showed that the ligament was best visualized at 90° compared to 145° in the dorsal (Z= −3.906,P= 0.000), axial (Z= −3.398,P= 0.001), and sagittal (Z= −2.530,P= 0.011) planes. Findings supported the use of a 90° flexed stifle position for maximizing visualization of the cranial cruciate ligament using low‐field MRI in dogs.


  • EFFECT OF VENTILATION TECHNIQUE AND AIRWAY DIAMETER ON BRONCHIAL LUMEN TO PULMONARY ARTERY DIAMETER RATIOS IN CLINICALLY NORMAL BEAGLE DOGS

    by Mariano Makara, Matthias Dennler, Manuela Schnyder, Rima Bektas, Patrick Kircher, Evelyn Hall, Tony Glaus

    In dogs, a mean broncho-arterial ratio of 1.45 ± 0.21 has been previously defined as normal. These values were obtained in dogs under general inhalational anesthesia using a single breath-hold technique. The purpose of the study was to determine whether ventilation technique and bronchial diameter have an effect on broncho-arterial ratios. Four healthy Beagle dogs were scanned twice, each time with positive-pressure inspiration and end expiration. For each ventilation technique, broncho-arterial ratios were grouped into those obtained from small or large bronchi using the median diameter of the bronchi as the cutoff value. Mean broncho-arterial ratios obtained using positive-pressure inspiration (1.24 ± 0.23) were statistically greater than those obtained at end expiration (1.11 ± 0.20) P = 0.005. There was a strong positive correlation between bronchial diameter and broncho-arterial ratios for both ventilation techniques (positive-pressure inspiration rs = .786, P < 0.0005 and end expiration rs = .709, P < 0.0005). Mean broncho-arterial ratio for the large bronchi obtained applying positive-pressure inspiration was 1.39 cm ± 0.20 and during end expiration was 1.22 cm ± 0.20. Mean broncho-arterial ratio for the small bronchi obtained during positive-pressure inspiration was 1.08 cm ± 0.13 and during end expiration was 1.01 cm ± 0.13. There was a statistically significant difference between these groups (F = 248.60, P = 0.005). Findings indicated that reference values obtained using positive-pressure inspiration or from the larger bronchi may not be applicable to dogs scanned during end expiration or to the smaller bronchi.