Nima Tajbakhsh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nima Tajbakhsh has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Jianming Liang
Arizona State University
6 shared publications Hong Wu
Department of Biomedical Informatics, Arizona State University, Scottsdale, Arizona, USA
2 shared publicationsJae Y. Shin
Arizona State University
2 shared publicationsSuryakanth R. Gurudu
Mayo Clinic
2 shared publications- Wenzhe Xue
Department of Biomedical Informatics, Arizona State University, Scottsdale, USA
2 shared publications Changching Chi
Arizona State University
1 shared publication
Latest Publications
- 14 July 2017
- Published by Springer Nature
- p. 181-193
On the Necessity of Fine-Tuned Convolutional Neural Networks for Medical Imaging
- 14 July 2017
- Published by Springer Nature
- p. 181-193
On the Necessity of Fine-Tuned Convolutional Neural Networks for Medical Imaging
- Open Access
Automating Carotid Intima-Media Thickness Video Interpretation with Convolutional Neural Networks
Cardiovascular disease (CVD) is the leading cause of mortality yet largely preventable, but the key to prevention is to identify at-risk individuals before adverse events. For predicting individual CVD risk, carotid intima-media thickness (CIMT), a noninvasive ultrasound method, has proven to be valuable, offering several advantages over CT coronary artery calcium score. However, each CIMT examination includes several ultrasound videos, and interpreting each of these CIMT videos involves three operations: (1) select three end-diastolic ultrasound frames (EUF) in the video, (2) localize a region of interest (ROI) in each selected frame, and (3) trace the lumen-intima interface and the media-adventitia interface in each ROI to measure CIMT. These operations are tedious, laborious, and time consuming, a serious limitation that hinders the widespread utilization of CIMT in clinical practice. To overcome this limitation, this paper presents a new system to automate CIMT video interpretation. Our extensive experiments demonstrate that the suggested system significantly outperforms the state-of-the-art methods. The superior performance is attributable to our unified framework based on convolutional neural networks (CNNs) coupled with our informative image representation and effective post-processing of the CNN outputs, which are uniquely designed for each of the above three operations.
Open AccessAutomating Carotid Intima-Media Thickness Video Interpretation with Convolutional Neural Networks
Cardiovascular disease (CVD) is the leading cause of mortality yet largely preventable, but the key to prevention is to identify at-risk individuals before adverse events. For predicting individual CVD risk, carotid intima-media thickness (CIMT), a noninvasive ultrasound method, has proven to be valuable, offering several advantages over CT coronary artery calcium score. However, each CIMT examination includes several ultrasound videos, and interpreting each of these CIMT videos involves three operations: (1) select three end-diastolic ultrasound frames (EUF) in the video, (2) localize a region of interest (ROI) in each selected frame, and (3) trace the lumen-intima interface and the media-adventitia interface in each ROI to measure CIMT. These operations are tedious, laborious, and time consuming, a serious limitation that hinders the widespread utilization of CIMT in clinical practice. To overcome this limitation, this paper presents a new system to automate CIMT video interpretation. Our extensive experiments demonstrate that the suggested system significantly outperforms the state-of-the-art methods. The superior performance is attributable to our unified framework based on convolutional neural networks (CNNs) coupled with our informative image representation and effective post-processing of the CNN outputs, which are uniquely designed for each of the above three operations.
- 23 June 2015
- Published by Springer Nature
- Vol. 24, 327-338
A Comprehensive Computer-Aided Polyp Detection System for Colonoscopy Videos
Computer-aided detection (CAD) can help colonoscopists reduce their polyp miss-rate, but existing CAD systems are handicapped by using either shape, texture, or temporal information for detecting polyps, achieving limited sensitivity and specificity. To overcome this limitation, our key contribution of this paper is to fuse all possible polyp features by exploiting the strengths of each feature while minimizing its weaknesses. Our new CAD system has two stages, where the first stage builds on the robustness of shape features to reliably generate a set of candidates with a high sensitivity, while the second stage utilizes the high discriminative power of the computationally expensive features to effectively reduce false positives. Specifically, we employ a unique edge classifier and an original voting scheme to capture geometric features of polyps in context and then harness the power of convolutional neural networks in a novel score fusion approach to extract and combine shape, color, texture, and temporal information of the candidates. Our experimental results based on FROC curves and a new analysis of polyp detection latency demonstrate a superiority over the state-of-the-art where our system yields a lower polyp detection latency and achieves a significantly higher sensitivity while generating dramatically fewer false positives. This performance improvement is attributed to our reliable candidate generation and effective false positive reduction methods.
- 23 June 2015
- Published by Springer Nature
- Vol. 24, 327-338
A Comprehensive Computer-Aided Polyp Detection System for Colonoscopy Videos
Computer-aided detection (CAD) can help colonoscopists reduce their polyp miss-rate, but existing CAD systems are handicapped by using either shape, texture, or temporal information for detecting polyps, achieving limited sensitivity and specificity. To overcome this limitation, our key contribution of this paper is to fuse all possible polyp features by exploiting the strengths of each feature while minimizing its weaknesses. Our new CAD system has two stages, where the first stage builds on the robustness of shape features to reliably generate a set of candidates with a high sensitivity, while the second stage utilizes the high discriminative power of the computationally expensive features to effectively reduce false positives. Specifically, we employ a unique edge classifier and an original voting scheme to capture geometric features of polyps in context and then harness the power of convolutional neural networks in a novel score fusion approach to extract and combine shape, color, texture, and temporal information of the candidates. Our experimental results based on FROC curves and a new analysis of polyp detection latency demonstrate a superiority over the state-of-the-art where our system yields a lower polyp detection latency and achieves a significantly higher sensitivity while generating dramatically fewer false positives. This performance improvement is attributed to our reliable candidate generation and effective false positive reduction methods.
- 11 December 2014
- Published by Springer Nature
- p. 151-158
Automatic Assessment of Image Informativeness in Colonoscopy
- 11 December 2014
- Published by Springer Nature
- p. 151-158
Automatic Assessment of Image Informativeness in Colonoscopy
- 22 August 2013
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 39 (11) , 2066-2074
Motion Analysis of Right Ventricular Dysfunction Under Mild or Moderate Pressure Overload Caused by Acute Pulmonary Embolism
- 22 August 2013
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 39 (11) , 2066-2074
Motion Analysis of Right Ventricular Dysfunction Under Mild or Moderate Pressure Overload Caused by Acute Pulmonary Embolism
- 26 October 2012
- Published by Springer Nature in Machine Vision and Applications
- Vol. 24 (7) , 1359-1370
A novel online boosting algorithm for automatic anatomy detection
- 26 October 2012
- Published by Springer Nature in Machine Vision and Applications
- Vol. 24 (7) , 1359-1370
A novel online boosting algorithm for automatic anatomy detection
- 23 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8315, 831539
Self-adaptive asymmetric on-line boosting for detecting anatomical structures
In this paper, we propose a self-adaptive, asymmetric on-line boosting (SAAOB) method for detecting anatomical structures in CT pulmonary angiography (CTPA). SAAOB is novel in that it exploits a new asymmetric loss criterion with self-adaptability according to the ratio of exposed positive and negative samples and in that it has an advanced rule to update sample's importance weight taking account of both classification result and sample's label. Our presented method is evaluated by detecting three distinct thoracic structures, the carina, the pulmonary trunk and the aortic arch, in both balanced and imbalanced conditions.
- 23 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8315, 831539
Self-adaptive asymmetric on-line boosting for detecting anatomical structures
In this paper, we propose a self-adaptive, asymmetric on-line boosting (SAAOB) method for detecting anatomical structures in CT pulmonary angiography (CTPA). SAAOB is novel in that it exploits a new asymmetric loss criterion with self-adaptability according to the ratio of exposed positive and negative samples and in that it has an advanced rule to update sample's importance weight taking account of both classification result and sample's label. Our presented method is evaluated by detecting three distinct thoracic structures, the carina, the pulmonary trunk and the aortic arch, in both balanced and imbalanced conditions.