M. Bouvier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
M. Bouvier has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Karine Baumstarck
EA 3279, CEReSS - Research Centre on Health Services and Quality of Life, Aix Marseille University, 27, boulevard Jean-Moulin, 13385 Marseille, France
2 shared publications - Véronique Vitton
Department of Gastroenterology, Hôpital Nord, Assistance Publique–Hôpitaux de Marseille, Aix-Marseille Université, Marseille, France
2 shared publications A. Benezech
Service de Gastroentérologie, Hôpital Nord, University Hospital, APHM, Marseille, France
1 shared publication- C. Brunet
Université Aix-Marseille, Service de Chirurgie Générale et Digestive, Laboratoire de Biomécanique Appliquée (UMR 24), Hôpital Nord, AP-HM, Chemin des Bourrely, 13915 Marseille, France
1 shared publication C. Visée
1 shared publicationJ.-C. Grimaud
Service de Gastroentérologie; CHU Nord; Marseille France
1 shared publication
Latest Publications
- 12 April 2014
- Published by Wiley in Colorectal Disease
- Vol. 16 (5) , O170-O175
Three‐dimensional high‐resolution anorectal manometry and diagnosis of excessive perineal descent: a comparative pilot study with defaecography
Three-dimensional high-resolution anorectal manometry (3DHRAM) is a new technique that can simultaneously provide physiological and topographical data on the terminal part of the digestive tract. Our object was to assess whether 3DHRAM is able to reliably diagnose excessive perineal descent already diagnosed with conventional defaecography, which is considered to be the gold standard. All patients referred to our centre for anorectal manometry and conventional defaecography were evaluated with a maximum of 6 months between the two examinations. Anorectal manometry was performed using the 3D High-Resolution Given Imaging® probe. Excessive perineal descent was defined as the downward movement of the anal high-pressure zone during straining. At the end of the straining effort, the high-pressure zone regained its initial position, thereby indicating that the probe had not moved. Nineteen female patients of median age 53 (21-70) years were included in the study. All cases with excessive perineal descent diagnosed using defaecography were visualized with 3DHRAM. The degree of perineal descent determined by 3D and conventional defaecography was compared (Spearman correlation 0.726, P = 0.01). In contrast, the averages measured were significantly different; the average was 11.68 ± 3.3 mm for 3DHRAM but 34.21 ± 13.3 mm for conventional defaecography (P = 0.002). The results of the study demonstrate that 3DHRAM can diagnose excessive perineal descent with the same degree of reliability as defaecography. Quantitative measures were not correlated, however, possibly because of methodological differences. The study confirms the value of the morphological data provided by 3DHRAM.
- 12 April 2014
- Published by Wiley in Colorectal Disease
- Vol. 16 (5) , O170-O175
Three‐dimensional high‐resolution anorectal manometry and diagnosis of excessive perineal descent: a comparative pilot study with defaecography
Three-dimensional high-resolution anorectal manometry (3DHRAM) is a new technique that can simultaneously provide physiological and topographical data on the terminal part of the digestive tract. Our object was to assess whether 3DHRAM is able to reliably diagnose excessive perineal descent already diagnosed with conventional defaecography, which is considered to be the gold standard. All patients referred to our centre for anorectal manometry and conventional defaecography were evaluated with a maximum of 6 months between the two examinations. Anorectal manometry was performed using the 3D High-Resolution Given Imaging® probe. Excessive perineal descent was defined as the downward movement of the anal high-pressure zone during straining. At the end of the straining effort, the high-pressure zone regained its initial position, thereby indicating that the probe had not moved. Nineteen female patients of median age 53 (21-70) years were included in the study. All cases with excessive perineal descent diagnosed using defaecography were visualized with 3DHRAM. The degree of perineal descent determined by 3D and conventional defaecography was compared (Spearman correlation 0.726, P = 0.01). In contrast, the averages measured were significantly different; the average was 11.68 ± 3.3 mm for 3DHRAM but 34.21 ± 13.3 mm for conventional defaecography (P = 0.002). The results of the study demonstrate that 3DHRAM can diagnose excessive perineal descent with the same degree of reliability as defaecography. Quantitative measures were not correlated, however, possibly because of methodological differences. The study confirms the value of the morphological data provided by 3DHRAM.
- 24 October 2013
- Published by Wiley in Colorectal Disease
- Vol. 15 (10) , e607-e611
Comparison of three-dimensional high-resolution manometry and endoanal ultrasound in the diagnosis of anal sphincter defects
Three-dimensional high-resolution anorectal manometry (3D HRAM) is a new technique that can simultaneously provide physiological and topographical data. Our aim was to assess whether it can identify anal sphincter defects by comparing it with endoanal ultrasonography (EUS) considered as the gold standard. An anal defect on 3D HRAM was defined as a continuous circumferential area over which the pressure was < 10 mmHg during the measurement of anal resting and voluntary contraction pressure. Inter-observer agreement was also assessed. A total of 100 patients (93 females) with a mean age of 53.5 ± 15.3 years were included. The positive diagnosis of an anal sphincter defect using 3D HRAM and EUS was in agreement (59.3%) (κ = 0.419) of the time for the internal anal sphincter (IAS) and (55.9%) (κ = 0.461) for the external anal sphincter (EAS). The inter-observer agreement for a diagnosis of an anal sphincter defect was (100%) (κ = 0.937) for the IAS and (95%) (κ = 0.751) for the EAS. The intra-class correlation coefficient for the extent of the defect was 0.853 for the IAS and 0.651 for the EAS. The preliminary results demonstrate some level of agreement in the diagnosis of anal sphincter defects between 3D HRAM and EUS but insufficient for 3D HRAM to be adequately reliable using the criteria chosen. The excellent inter-observer agreement, however, demonstrates that 3D HRAM is reproducible and provides a new dimension for the evaluation of sphincter function.
- 24 October 2013
- Published by Wiley in Colorectal Disease
- Vol. 15 (10) , e607-e611
Comparison of three-dimensional high-resolution manometry and endoanal ultrasound in the diagnosis of anal sphincter defects
Three-dimensional high-resolution anorectal manometry (3D HRAM) is a new technique that can simultaneously provide physiological and topographical data. Our aim was to assess whether it can identify anal sphincter defects by comparing it with endoanal ultrasonography (EUS) considered as the gold standard. An anal defect on 3D HRAM was defined as a continuous circumferential area over which the pressure was < 10 mmHg during the measurement of anal resting and voluntary contraction pressure. Inter-observer agreement was also assessed. A total of 100 patients (93 females) with a mean age of 53.5 ± 15.3 years were included. The positive diagnosis of an anal sphincter defect using 3D HRAM and EUS was in agreement (59.3%) (κ = 0.419) of the time for the internal anal sphincter (IAS) and (55.9%) (κ = 0.461) for the external anal sphincter (EAS). The inter-observer agreement for a diagnosis of an anal sphincter defect was (100%) (κ = 0.937) for the IAS and (95%) (κ = 0.751) for the EAS. The intra-class correlation coefficient for the extent of the defect was 0.853 for the IAS and 0.651 for the EAS. The preliminary results demonstrate some level of agreement in the diagnosis of anal sphincter defects between 3D HRAM and EUS but insufficient for 3D HRAM to be adequately reliable using the criteria chosen. The excellent inter-observer agreement, however, demonstrates that 3D HRAM is reproducible and provides a new dimension for the evaluation of sphincter function.
- 1 October 2013
- Published by Elsevier in Morphologie
- Vol. 97 (318) , 92
Vers une meilleure compréhension des mécanismes pathologiques de la région périnéale
- 1 October 2013
- Published by Elsevier in Morphologie
- Vol. 97 (318) , 92
Vers une meilleure compréhension des mécanismes pathologiques de la région périnéale
- 1 January 2013
- Published by Springer Nature
- p. 3-10
Physiopathologie