Ian L. Gordon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ian L. Gordon has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Jonathan M. Tobis
2 shared publicationsSamuel E. Wilson
2 shared publicationsA Bergman
1 shared publicationEdward A. Stemmer
1 shared publicationGanesha B. Perera
1 shared publicationJ Griffith
1 shared publication
Latest Publications
- 1 March 2004
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 18 (2) , 172-177
Dose-dependent Inhibition of Myointimal Hyperplasia by Orally Administered Rapamycin
- 1 March 2004
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 18 (2) , 172-177
Dose-dependent Inhibition of Myointimal Hyperplasia by Orally Administered Rapamycin
- Open Access
- 1 February 2001
- Published by American Medical Association (AMA) in Archives of Surgery
- Vol. 136 (2) , 221-228
Three-Year Outcome of Endovascular Treatment of Superficial Femoral Artery Occlusion
IN RECENT years increasing numbers of patients with stenosis and occlusion of the femoropopliteal segment of the arterial tree have been treated with percutaneous transluminal angioplasty (PTA) or PTA with stenting. In previously reported series, many subjects underwent stenting for management of suboptimal PTA results or after failure of previous interventions.1-3 Although the long-term results of stenting the superficial femoral artery (SFA) may not be better than PTA alone,4 previous outcomes may have reflected an unfavorable bias, given the large proportion of cases in which stents were used after previous endovascular failures. This article summarizes the consecutive experience of a radiology-surgery team at 1 institution with a consistent treatment strategy using stenting. Each subject had a chronic femoropopliteal occlusion and had never undergone previous infrainguinal therapy. A similar technique of mechanical guidewire recanalization, PTA, and stenting was applied to each case. We have examined patency rates, limb salvage outcomes, and complications and account for the total number of interventions required to implement this novel strategy.
- 1 February 2001
- Published by American Medical Association (AMA) in Archives of Surgery
- Vol. 136 (2) , 221-228
Open AccessThree-Year Outcome of Endovascular Treatment of Superficial Femoral Artery Occlusion
IN RECENT years increasing numbers of patients with stenosis and occlusion of the femoropopliteal segment of the arterial tree have been treated with percutaneous transluminal angioplasty (PTA) or PTA with stenting. In previously reported series, many subjects underwent stenting for management of suboptimal PTA results or after failure of previous interventions.1-3 Although the long-term results of stenting the superficial femoral artery (SFA) may not be better than PTA alone,4 previous outcomes may have reflected an unfavorable bias, given the large proportion of cases in which stents were used after previous endovascular failures. This article summarizes the consecutive experience of a radiology-surgery team at 1 institution with a consistent treatment strategy using stenting. Each subject had a chronic femoropopliteal occlusion and had never undergone previous infrainguinal therapy. A similar technique of mechanical guidewire recanalization, PTA, and stenting was applied to each case. We have examined patency rates, limb salvage outcomes, and complications and account for the total number of interventions required to implement this novel strategy.
- 1 June 1992
- Vol. 6 (2) , 109-16
Anatomic and functional assessment of stenosis severity with intravascular ultrasound imaging in vitro.
An in vitro study was performed to evaluate the accuracy of intravascular ultrasound imaging compared with roentgenography for determining the cross-sectional area of a lumen; and to determine if the functional significance of an irregular stenosis is predicted more accurately by intravascular ultrasound than roentgenography. Varying degrees of stenosis were made in 17 rubber tubings by adjusting a plastic constrictor. The cross-sectional areas at the normal and the stenotic segments were determined by intravascular ultrasound, roentgenography, and then measured directly from an acrylamide gel cast of the lumen. To evaluate the functional significance of a stenosis, the pressure drop across the stenosis was measured using a fluid pumping circuit. The actual pressure drop was then compared with the predicted pressure drop derived from hydrodynamic equations using cross-sectional areas obtained by intravascular ultrasound or roentgenography. There was an excellent correlation between the cross-sectional areas at the tightest stenosis measured by intravascular ultrasound compared with the area from the acrylamide cast (7.2 +/- 2.6 v 6.6 +/- 2.4 mm 2, mean +/- SD, r = .93). Measurements of cross-sectional area from the roentgenograms (10.9 +/- 3.9 mm 2) also provided a relatively good correlation with those from the acrylamide casts (r = .84); however, the roentgenograms consistently overestimated the cross-sectional area of the stenosis. The mean values of the actual pressure drop and the predicted pressure drop by intravascular ultrasound and roentgenograms were 15.7 +/- 13.5, 11.3 +/- 11.9, and 4.3 +/- 4.5 mmHg, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)
- 1 June 1992
- Vol. 6 (2) , 109-16
Anatomic and functional assessment of stenosis severity with intravascular ultrasound imaging in vitro.
An in vitro study was performed to evaluate the accuracy of intravascular ultrasound imaging compared with roentgenography for determining the cross-sectional area of a lumen; and to determine if the functional significance of an irregular stenosis is predicted more accurately by intravascular ultrasound than roentgenography. Varying degrees of stenosis were made in 17 rubber tubings by adjusting a plastic constrictor. The cross-sectional areas at the normal and the stenotic segments were determined by intravascular ultrasound, roentgenography, and then measured directly from an acrylamide gel cast of the lumen. To evaluate the functional significance of a stenosis, the pressure drop across the stenosis was measured using a fluid pumping circuit. The actual pressure drop was then compared with the predicted pressure drop derived from hydrodynamic equations using cross-sectional areas obtained by intravascular ultrasound or roentgenography. There was an excellent correlation between the cross-sectional areas at the tightest stenosis measured by intravascular ultrasound compared with the area from the acrylamide cast (7.2 +/- 2.6 v 6.6 +/- 2.4 mm 2, mean +/- SD, r = .93). Measurements of cross-sectional area from the roentgenograms (10.9 +/- 3.9 mm 2) also provided a relatively good correlation with those from the acrylamide casts (r = .84); however, the roentgenograms consistently overestimated the cross-sectional area of the stenosis. The mean values of the actual pressure drop and the predicted pressure drop by intravascular ultrasound and roentgenograms were 15.7 +/- 13.5, 11.3 +/- 11.9, and 4.3 +/- 4.5 mmHg, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)