Jinshi Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jinshi Wang has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Junjie Yan
Xi’an Jiaotong University
10 shared publications - Daotong Chong
State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University , Xi'an 710049
6 shared publications Xiping Chen
4 shared publicationsRonghai Huang
3 shared publicationsYong Li
3 shared publicationsYuanzhi Qin
3 shared publications
Latest Publications
- Open Access
- 6 January 2026
- Published by Elsevier in Energy Reports
- Vol. 15
Multi-timescale scheduling of multi-energy complementary system for desert-gobi-wasteland region considering source-load uncertainties
- 6 January 2026
- Published by Elsevier in Energy Reports
- Vol. 15
Open AccessMulti-timescale scheduling of multi-energy complementary system for desert-gobi-wasteland region considering source-load uncertainties
- 1 September 2025
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 17 (5)
Optimal transformation pathway of power systems based on low-carbon targets: A case study of a coastal province in China
Low-carbon transformation for power systems is crucial for achieving the carbon reduction targets outlined in the Paris Agreement. However, significant disparities in resource endowments and levels of development across different regions present considerable challenges for planners in formulating transformation plans that are appropriately tailored to local conditions. To confront this challenge, a multi-source integrated regional power systems planning model is developed, accounting for regional differences and the temporal evolution of generation technologies. This model is used to identify the most cost-effective low-carbon planning pathway for power systems, while also analyzing the sensitivity intensity of key factors influencing capacity planning and emission intensity. Taking a coastal province of China as a case study, three carbon emission constraint scenarios are studied: a basic scenario (BA), a carbon neutral scenario (PN), and a rapid carbon neutral scenario (RA). The results indicate that by 2050, under more stringent constraints, PN and RA scenarios would require reductions in carbon emissions of 1752.4 and 2105.3 Mt, respectively, compared to the BA scenario. The development of clean energy is expected to accelerate significantly. By 2050, under the PN and RA scenarios, the installed capacity of clean energy will be 29.0% and 34.1% higher, respectively, than under the BA scenario, while power generation will increase by 36.0% and 41.2%, respectively. However, the total investment under the PN and RA scenarios will be $37.7 billion and $41.0 billion higher, respectively, than that under the BA scenario.
- 1 September 2025
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 17 (5)
Optimal transformation pathway of power systems based on low-carbon targets: A case study of a coastal province in China
Low-carbon transformation for power systems is crucial for achieving the carbon reduction targets outlined in the Paris Agreement. However, significant disparities in resource endowments and levels of development across different regions present considerable challenges for planners in formulating transformation plans that are appropriately tailored to local conditions. To confront this challenge, a multi-source integrated regional power systems planning model is developed, accounting for regional differences and the temporal evolution of generation technologies. This model is used to identify the most cost-effective low-carbon planning pathway for power systems, while also analyzing the sensitivity intensity of key factors influencing capacity planning and emission intensity. Taking a coastal province of China as a case study, three carbon emission constraint scenarios are studied: a basic scenario (BA), a carbon neutral scenario (PN), and a rapid carbon neutral scenario (RA). The results indicate that by 2050, under more stringent constraints, PN and RA scenarios would require reductions in carbon emissions of 1752.4 and 2105.3 Mt, respectively, compared to the BA scenario. The development of clean energy is expected to accelerate significantly. By 2050, under the PN and RA scenarios, the installed capacity of clean energy will be 29.0% and 34.1% higher, respectively, than under the BA scenario, while power generation will increase by 36.0% and 41.2%, respectively. However, the total investment under the PN and RA scenarios will be $37.7 billion and $41.0 billion higher, respectively, than that under the BA scenario.
- 7 July 2024
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 61 (12) , 1582-1599
Dynamic performance analysis of a new low-temperature nuclear heating system with APROS
- 7 July 2024
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 61 (12) , 1582-1599
Dynamic performance analysis of a new low-temperature nuclear heating system with APROS
- 1 April 2021
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 43 (8-10) , 708-719
Experimental Study on Pressure Drop and Heat Transfer Characteristics of Wet Air with Ash Particles across Circular Finned Tube Bundles
In this paper, in order to provide guidance on the design and operation of waste heat recovery heat exchangers for the dryer exhaust of lignite pre-drying, pressure drop and heat transfer characteristics of wet air with ash particles across circular finned tube bundles were experimentally studied under different conditions. The experimental water vapor mass fraction ranged from 5% to 15%, ash particle concentration ranged from 0 to 12.8 g/m3 and mainstream flow velocity ranged from 1.73 m/s to 3.46 m/s, respectively. The pressure drop coefficient generally increases and Nusselt number decreases with time due to the gradual ash deposition. The pressure drop coefficient is sensitive to ash particle concentration, while Nusselt number is sensitive to water vapor mass fraction. Especially, Nusselt number for the ash particle concentration of 1.5 − 5.4 g/m3 is a bit larger than that for the wet air without ash particles. Based on the experimental data, a normalized empirical formula was proposed to calculate the heat transfer characteristics of wet air with ash particles across circular finned tube bundles, and the deviation between experimental data and predicted results is −16.5% to +27.0% for more than 90% of the data.
- 1 April 2021
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 43 (8-10) , 708-719
Experimental Study on Pressure Drop and Heat Transfer Characteristics of Wet Air with Ash Particles across Circular Finned Tube Bundles
In this paper, in order to provide guidance on the design and operation of waste heat recovery heat exchangers for the dryer exhaust of lignite pre-drying, pressure drop and heat transfer characteristics of wet air with ash particles across circular finned tube bundles were experimentally studied under different conditions. The experimental water vapor mass fraction ranged from 5% to 15%, ash particle concentration ranged from 0 to 12.8 g/m3 and mainstream flow velocity ranged from 1.73 m/s to 3.46 m/s, respectively. The pressure drop coefficient generally increases and Nusselt number decreases with time due to the gradual ash deposition. The pressure drop coefficient is sensitive to ash particle concentration, while Nusselt number is sensitive to water vapor mass fraction. Especially, Nusselt number for the ash particle concentration of 1.5 − 5.4 g/m3 is a bit larger than that for the wet air without ash particles. Based on the experimental data, a normalized empirical formula was proposed to calculate the heat transfer characteristics of wet air with ash particles across circular finned tube bundles, and the deviation between experimental data and predicted results is −16.5% to +27.0% for more than 90% of the data.
- 1 January 2021
- Published by Japan Society of Mechanical Engineers in The Proceedings of the International Conference on Power Engineering (ICOPE)
- Vol. 2021.15, 2021-0227-0227
Multiple load short-term forecasting model of integrated energy system based on multiple LSTM networks
Accurate short-term load forecasting of integrated energy system can optimize system operation and play an important role in improving system energy efficiency. In this paper, a multiple load short-term forecasting model of integrated energy system based on multiple LSTM networks is proposed. Firstly, the load influencing factors are divided into meteorological characteristic, delay characteristic and periodic characteristic, and the correlation is calculated based on Pearson coefficient. Secondly, a load forecasting model with multiple LSTM network coupling is established to explore the relationship between load and three characteristics, and excavate the complex coupling relationship among cooling, heating and power. The results show that the model has better prediction performance compared with other commonly used models.
- 1 January 2021
- Published by Japan Society of Mechanical Engineers in The Proceedings of the International Conference on Power Engineering (ICOPE)
- Vol. 2021.15, 2021-0227-0227
Multiple load short-term forecasting model of integrated energy system based on multiple LSTM networks
Accurate short-term load forecasting of integrated energy system can optimize system operation and play an important role in improving system energy efficiency. In this paper, a multiple load short-term forecasting model of integrated energy system based on multiple LSTM networks is proposed. Firstly, the load influencing factors are divided into meteorological characteristic, delay characteristic and periodic characteristic, and the correlation is calculated based on Pearson coefficient. Secondly, a load forecasting model with multiple LSTM network coupling is established to explore the relationship between load and three characteristics, and excavate the complex coupling relationship among cooling, heating and power. The results show that the model has better prediction performance compared with other commonly used models.
- Open Access
Modeling Study on Heat Transfer in Marangoni Dropwise Condensation for Ethanol-Water Mixture Vapors
In this paper, a model was developed to predict the heat transfer characteristics of Marangoni dropwise condensation. In accordance with the feature of Marangoni condensation, condensation was treated as dropwise condensation of mixture vapors. The condensation space was divided into two parts: the vapor diffusion layer and the condensate layer. For the condensate layer, the classical heat transfer calculation method of dropwise condensation was imitated to obtain the heat transfer characteristics. For the vapor diffusion layer, the heat transfer characteristics were achieved by solving the conservation equations. These heat transfer characteristics were coupled through the conjunct boundary, which was the vapor-liquid interface. The model was applied to the condensation of water-ethanol mixture vapors. A comparison with the existing experimental data showed that the developed model could basically reflect the influences of vapor-to-surface temperature difference, vapor concentration, vapor pressure, and vapor velocity on heat transfer characteristic of Marangoni condensation. Results showed that some differences existed between the calculation results and experimental results, but the prediction deviation of the model could be acceptable in the range of vapor-to-surface temperature difference where the condensation heat transfer coefficients reached peak values.
Open AccessModeling Study on Heat Transfer in Marangoni Dropwise Condensation for Ethanol-Water Mixture Vapors
In this paper, a model was developed to predict the heat transfer characteristics of Marangoni dropwise condensation. In accordance with the feature of Marangoni condensation, condensation was treated as dropwise condensation of mixture vapors. The condensation space was divided into two parts: the vapor diffusion layer and the condensate layer. For the condensate layer, the classical heat transfer calculation method of dropwise condensation was imitated to obtain the heat transfer characteristics. For the vapor diffusion layer, the heat transfer characteristics were achieved by solving the conservation equations. These heat transfer characteristics were coupled through the conjunct boundary, which was the vapor-liquid interface. The model was applied to the condensation of water-ethanol mixture vapors. A comparison with the existing experimental data showed that the developed model could basically reflect the influences of vapor-to-surface temperature difference, vapor concentration, vapor pressure, and vapor velocity on heat transfer characteristic of Marangoni condensation. Results showed that some differences existed between the calculation results and experimental results, but the prediction deviation of the model could be acceptable in the range of vapor-to-surface temperature difference where the condensation heat transfer coefficients reached peak values.
- 1 December 2020
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 370, 110862
Numerical study on melt drop collision and hydraulic fragmentation during FCI of a nuclear reactor severe accident
- 1 December 2020
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 370, 110862
Numerical study on melt drop collision and hydraulic fragmentation during FCI of a nuclear reactor severe accident
- Open Access
Theoretical Design and Analysis of the Waste Heat Recovery System of Turbine Exhaust Steam Using an Absorption Heat Pump for Heating Supply
In northern China, many thermal power plants use absorption heat pump to recover low-grade heat from turbine exhaust steam due to the irreplaceable advantages of the absorption heat pump in waste heat recovery. In the process of designing a waste heat recovery system, few researchers have considered the relationship between the design power of the heat pump and the actual heating load of the heating network. Based on the heating load characteristics, this paper puts forward a design idea which uses an absorption heat pump to recover waste heat from a steam turbine exhaust for heating supply. The operation mode of the system for different design powers of the heat pump was stated. An economic analysis model of the waste heat recovery system was proposed, and the optimal design power of the heat pump could be obtained. For a specific unit, the corresponding waste heat recovery system was designed, and various factors affecting the economy of the system were discussed and analyzed in detail.
Open AccessTheoretical Design and Analysis of the Waste Heat Recovery System of Turbine Exhaust Steam Using an Absorption Heat Pump for Heating Supply
In northern China, many thermal power plants use absorption heat pump to recover low-grade heat from turbine exhaust steam due to the irreplaceable advantages of the absorption heat pump in waste heat recovery. In the process of designing a waste heat recovery system, few researchers have considered the relationship between the design power of the heat pump and the actual heating load of the heating network. Based on the heating load characteristics, this paper puts forward a design idea which uses an absorption heat pump to recover waste heat from a steam turbine exhaust for heating supply. The operation mode of the system for different design powers of the heat pump was stated. An economic analysis model of the waste heat recovery system was proposed, and the optimal design power of the heat pump could be obtained. For a specific unit, the corresponding waste heat recovery system was designed, and various factors affecting the economy of the system were discussed and analyzed in detail.
- Open Access
Surface Temperature Distribution Characteristics of Marangoni Condensation for Ethanol–Water Mixture Vapor Based on Thermal Infrared Images
Marangoni condensation is formed due to the surface tension gradient caused by the local temperature or concentration gradient on the condensate surface; thus, the investigation of the surface temperature distribution characteristics is crucial to reveal the condensation mechanism and heat transfer characteristics. Few studies have been conducted on the temperature distribution of the condensate surface. In this study, thermal infrared images were used to measure the temperature distributions of the condensate surface during Marangoni condensation for ethanol–water mixture vapor. The results showed that the surface temperature distribution of the single droplet was uneven, and a large temperature gradient, approximately 15.6 °C/mm, existed at the edge of the condensate droplets. The maximum temperature difference on the droplet surface reached up to 8 °C. During the condensation process, the average surface temperature of a single droplet firstly increased rapidly and then slowly until it approached a certain temperature, whereas that of the condensate surface increased rapidly at the beginning and then changed periodically in a cosine-like curve. The present results will be used to obtain local heat flux and heat transfer coefficients on the condensing surface, and to further establish the relationship between heat transfer and temperature distribution characteristics.
Open AccessSurface Temperature Distribution Characteristics of Marangoni Condensation for Ethanol–Water Mixture Vapor Based on Thermal Infrared Images
Marangoni condensation is formed due to the surface tension gradient caused by the local temperature or concentration gradient on the condensate surface; thus, the investigation of the surface temperature distribution characteristics is crucial to reveal the condensation mechanism and heat transfer characteristics. Few studies have been conducted on the temperature distribution of the condensate surface. In this study, thermal infrared images were used to measure the temperature distributions of the condensate surface during Marangoni condensation for ethanol–water mixture vapor. The results showed that the surface temperature distribution of the single droplet was uneven, and a large temperature gradient, approximately 15.6 °C/mm, existed at the edge of the condensate droplets. The maximum temperature difference on the droplet surface reached up to 8 °C. During the condensation process, the average surface temperature of a single droplet firstly increased rapidly and then slowly until it approached a certain temperature, whereas that of the condensate surface increased rapidly at the beginning and then changed periodically in a cosine-like curve. The present results will be used to obtain local heat flux and heat transfer coefficients on the condensing surface, and to further establish the relationship between heat transfer and temperature distribution characteristics.