A. Satish
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
A. Satish has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- D. Vijitha
Division of Prosthodontics, Rajah Muthiah Dental College and Hospital, Annamalai University, Chidambaram, Tamil Nadu, India
2 shared publications Subash M. Reddy
Department of Prosthodontics, Rajah Muthiah Dental College & Hospital, Annamalai University, Chidambaram, 608002 Tamil Nadu India
2 shared publications- Chenthil Aruun Mohan
Department of Prosthodontics, Rajah Muthiah Dental College & Hospital, Annamalai University, Chidambaram, 608002 Tamil Nadu India
1 shared publication Mahendira Kumar
Department of Prosthodontics, Rajah Muthiah Dental College & Hospital, Annamalai University, Chidambaram, 608002 Tamil Nadu India
1 shared publicationR. Balasubramanian
Deptartment of Prosthodontics, Rajah Muthiah Dental College & Hospital, Annamalai University, Chidambaram, 608002 Tamil Nadu India
1 shared publication- R. Balasubramanian
Department of Prosthodontics, Rajah Muthiah Dental College & Hospital, Annamalai University, Chidambaram, 608002 Tamil Nadu India
1 shared publication
Latest Publications
- Open Access
- 30 October 2012
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 13 (4) , 509-512
Pressure Produced on the Residual Maxillary Alveolar Ridge by Different Impression Materials and Tray Design: An In Vivo Study
Increased ridge resorption may occur due to inappropriate pressure applied during final impression making phase of complete denture fabrication. This study was done to evaluate the pressure applied on the residual ridge while making impressions with two tray designs (with and without spacer) using, zinc oxide eugenol and light body polyvinyl siloxane impression material. Five edentulous subjects were randomly selected. For each of the five subjects four maxillary final impressions were made and were labelled as, Group A-Impression made with tray without spacer using zinc oxide eugenol impression, Group B-Impression made with tray with spacer using zinc oxide eugenol impression material, Group C-Impression made with tray without spacer using light body polyvinyl siloxane impression material, Group D-Impression made with tray with spacer using light body polyvinyl siloxane impression material. During the impression procedure a closed hydraulic system was used to remotely measure the pressures produced in three areas. The pressure produced were calibrated according to the micro strain record. Statistical comparisons of readings were done using t test and ANOVA. The acquired data revealed that ZOE produced an average pressures value of 26.534 and 72.05 microstrain, while light body PVS produced 11.430 and 37.584 microstrain value with and without spacer respectively. Significantly high values were recorded on the vault of the palate when using trays without spacer. The use of light body polyvinyl siloxane and zinc oxide eugenol impression material showed insignificant difference. Within the limitations of this study, tray design has a significantly effected on the pressures produced, while the impression materials does not have any significant difference.
- 30 October 2012
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 13 (4) , 509-512
Open AccessPressure Produced on the Residual Maxillary Alveolar Ridge by Different Impression Materials and Tray Design: An In Vivo Study
Increased ridge resorption may occur due to inappropriate pressure applied during final impression making phase of complete denture fabrication. This study was done to evaluate the pressure applied on the residual ridge while making impressions with two tray designs (with and without spacer) using, zinc oxide eugenol and light body polyvinyl siloxane impression material. Five edentulous subjects were randomly selected. For each of the five subjects four maxillary final impressions were made and were labelled as, Group A-Impression made with tray without spacer using zinc oxide eugenol impression, Group B-Impression made with tray with spacer using zinc oxide eugenol impression material, Group C-Impression made with tray without spacer using light body polyvinyl siloxane impression material, Group D-Impression made with tray with spacer using light body polyvinyl siloxane impression material. During the impression procedure a closed hydraulic system was used to remotely measure the pressures produced in three areas. The pressure produced were calibrated according to the micro strain record. Statistical comparisons of readings were done using t test and ANOVA. The acquired data revealed that ZOE produced an average pressures value of 26.534 and 72.05 microstrain, while light body PVS produced 11.430 and 37.584 microstrain value with and without spacer respectively. Significantly high values were recorded on the vault of the palate when using trays without spacer. The use of light body polyvinyl siloxane and zinc oxide eugenol impression material showed insignificant difference. Within the limitations of this study, tray design has a significantly effected on the pressures produced, while the impression materials does not have any significant difference.
- Open Access
- 27 October 2012
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 14 (1) , 38-41
Evaluation of Shear Bond Strength of Zirconia Bonded to Dentin After Various Surface Treatments of Zirconia
Establishing a reliable bond of resin cement to zirconia based materials has been a major limitation against zirconia restoration. Purpose of study: This study evaluated the shear bond strength of zirconia bonded to dentin specimens using a self etch dual cure resin cement after various surface treatments of zirconia. Twenty zirconia rods (3 × 2.5 mm) were prepared from zirconia blocks and assigned into 5 groups for the following surface treatments. (1) Group I: Control (C) no treatment (2) Group II: airborne-particle abrasion (APA), (3) Group III: hydrofluoric acid etching (HF), (4) Group IV: hydrofluoric acid etching followed by silanation (HF/S), and (5) Group V: application of zirconia primer (Z). Dentin Specimens were prepared from extracted molars stored in 0.5% chloramine-T. Zirconia rods were bonded to dentin using resin cement (Multilink Speed), then light polymerized. The specimens tested for failure were tested using the notched shear bond test method in a universal loading apparatus. One way ANOVA followed by Tukey HSD for cell means were used to analyze the data (=0.05). The highest values were obtained with group V (Z) (8.66 MPa) followed by group II (APA) (6.71 MPa), and group IV (HF/S) (4.41 MPa). The least values were obtained for group III (HF) (3.88 MPa) with no significant difference (P value 0.53) between group III (HF) (3.88 MPa) and group I (C) (3.70 MPa). Among the surface treatments employed in this study zirconia primer application is a practical procedure to improved bond strength of zirconia to resin cement followed by Airborne Particle Abrasion with 50 μm Al2O3 particles.
- 27 October 2012
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 14 (1) , 38-41
Open AccessEvaluation of Shear Bond Strength of Zirconia Bonded to Dentin After Various Surface Treatments of Zirconia
Establishing a reliable bond of resin cement to zirconia based materials has been a major limitation against zirconia restoration. Purpose of study: This study evaluated the shear bond strength of zirconia bonded to dentin specimens using a self etch dual cure resin cement after various surface treatments of zirconia. Twenty zirconia rods (3 × 2.5 mm) were prepared from zirconia blocks and assigned into 5 groups for the following surface treatments. (1) Group I: Control (C) no treatment (2) Group II: airborne-particle abrasion (APA), (3) Group III: hydrofluoric acid etching (HF), (4) Group IV: hydrofluoric acid etching followed by silanation (HF/S), and (5) Group V: application of zirconia primer (Z). Dentin Specimens were prepared from extracted molars stored in 0.5% chloramine-T. Zirconia rods were bonded to dentin using resin cement (Multilink Speed), then light polymerized. The specimens tested for failure were tested using the notched shear bond test method in a universal loading apparatus. One way ANOVA followed by Tukey HSD for cell means were used to analyze the data (=0.05). The highest values were obtained with group V (Z) (8.66 MPa) followed by group II (APA) (6.71 MPa), and group IV (HF/S) (4.41 MPa). The least values were obtained for group III (HF) (3.88 MPa) with no significant difference (P value 0.53) between group III (HF) (3.88 MPa) and group I (C) (3.70 MPa). Among the surface treatments employed in this study zirconia primer application is a practical procedure to improved bond strength of zirconia to resin cement followed by Airborne Particle Abrasion with 50 μm Al2O3 particles.