Anna-Leena Manninen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anna-Leena Manninen has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
A. Karttunen
From the Department of Diagnostic Radiology (A.-L.M., J.-M.I., A.K., T.S., M.T.N.), Oulu University Hospital, Oulu, Finland
1 shared publicationA. Kotiaho
Department of Physical Sciences, Biophysics, University of Oulu, PO Box 3000, Oulu FI-90014, Finland
1 shared publication- Antti Pekkarinen
Department of Medical Physics, The Wellbeing Services County of Kymenlaakso, Kymenlaakso Central Hospital, Kotkantie 41, 48210 Kotka, Finland
1 shared publication - Arto Saarela
Department of Gastrointestinal Surgery, Oulu University Hospital, 90220 Oulu, Finland
1 shared publication - Carita Lindholm
STUK-Radiation and Nuclear Safety Authority, 00881 Helsinki, Finland
1 shared publication - Ekaterina Saukko
Department of Radiology, Turku University Hospital and University of Turku, Turku, Finland
1 shared publication
Latest Publications
- Open Access
- 21 March 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (6) , 656
Assessing Patient Radiation Exposure in Endoscopic Retrograde Cholangiopancreatography: A Multicenter Retrospective Analysis of Procedural Complexity and Clinical Factors
Background and aims: Endoscopic retrograde cholangiopancreatography (ERCP) procedures can result in significant patient radiation exposure. This retrospective multicenter study aimed to assess the influence of procedural complexity and other clinical factors on radiation exposure in ERCP. Methods: Data on kerma-area product (KAP), air-kerma at the reference point (Ka,r), fluoroscopy time, and the number of exposures, and relevant patient, procedure, and operator factors were collected from 2641 ERCP procedures performed at four university hospitals. The influence of procedural complexity, assessed using the American Society for Gastrointestinal Endoscopy (ASGE) and HOUSE complexity grading scales, on radiation exposure quantities was analyzed within each center. The procedures were categorized into two groups based on ERCP indications: primary sclerosing cholangitis (PSC) and other ERCPs. Results: Both the ASGE and HOUSE complexity grading scales had a significant impact on radiation exposure quantities. Remarkably, there was up to a 50-fold difference in dose quantities observed across the participating centers. For non-PSC ERCP procedures, the median KAP ranged from 0.9 to 64.4 Gy·cm2 among the centers. The individual endoscopist also had a substantial influence on radiation dose. Conclusions: Procedural complexity grading in ERCP significantly affects radiation exposure. Higher procedural complexity is typically associated with increased patient radiation dose. The ASGE complexity grading scale demonstrated greater sensitivity to changes in radiation exposure compared to the HOUSE grading scale. Additionally, significant variations in dose indices, fluoroscopy times, and number of exposures were observed across the participating centers.
- 21 March 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (6) , 656
Open AccessAssessing Patient Radiation Exposure in Endoscopic Retrograde Cholangiopancreatography: A Multicenter Retrospective Analysis of Procedural Complexity and Clinical Factors
Background and aims: Endoscopic retrograde cholangiopancreatography (ERCP) procedures can result in significant patient radiation exposure. This retrospective multicenter study aimed to assess the influence of procedural complexity and other clinical factors on radiation exposure in ERCP. Methods: Data on kerma-area product (KAP), air-kerma at the reference point (Ka,r), fluoroscopy time, and the number of exposures, and relevant patient, procedure, and operator factors were collected from 2641 ERCP procedures performed at four university hospitals. The influence of procedural complexity, assessed using the American Society for Gastrointestinal Endoscopy (ASGE) and HOUSE complexity grading scales, on radiation exposure quantities was analyzed within each center. The procedures were categorized into two groups based on ERCP indications: primary sclerosing cholangitis (PSC) and other ERCPs. Results: Both the ASGE and HOUSE complexity grading scales had a significant impact on radiation exposure quantities. Remarkably, there was up to a 50-fold difference in dose quantities observed across the participating centers. For non-PSC ERCP procedures, the median KAP ranged from 0.9 to 64.4 Gy·cm2 among the centers. The individual endoscopist also had a substantial influence on radiation dose. Conclusions: Procedural complexity grading in ERCP significantly affects radiation exposure. Higher procedural complexity is typically associated with increased patient radiation dose. The ASGE complexity grading scale demonstrated greater sensitivity to changes in radiation exposure compared to the HOUSE grading scale. Additionally, significant variations in dose indices, fluoroscopy times, and number of exposures were observed across the participating centers.
- Open Access
- 1 June 2020
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 190 (2) , 176-184
ESTIMATION OF HP(3) AMONG STAFF MEMBERS IN TWO NUCLEAR MEDICINE UNITS IN FINLAND
The eye lens exposure among 16 technicians in two nuclear medicine departments at university hospitals in Finland was investigated by measuring the operational quantity Hp(3) using EYE-D dosemeters. For all workers, the annual mean Hp(3) was estimated to be 1.1 mSv (max. 3.9 mSv). The relation between Hp(3) to routinely monitored personal dose equivalent Hp(10) was clearly correlated. Considering individual dose measurement periods (2–4 weeks), the Hp(3)/Hp(10) ratio was 0.7 (Pearson’s coefficient r = 0.90, p < 0.001, variation of ratio 0.1–2.3). The variation decreased considerably with increasing Hp(10) (σ2 = 0.04 vs. 0.43 for Hp(10) > 0.1 mSv vs. < 0.1 mSv, respectively), i.e. higher Hp(10) predicts Hp(3) more reliably. Moreover, annual Hp(10) data from national dose register during 2009–2018 were used to derive the annual Hp(3) applying the Hp(3)/Hp(10) ratio. The data from Finnish nuclear medicine departments imply that routine measurements of Hp(3) among nuclear medicine technicians are not justified.
- 1 June 2020
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 190 (2) , 176-184
Open AccessESTIMATION OF HP(3) AMONG STAFF MEMBERS IN TWO NUCLEAR MEDICINE UNITS IN FINLAND
The eye lens exposure among 16 technicians in two nuclear medicine departments at university hospitals in Finland was investigated by measuring the operational quantity Hp(3) using EYE-D dosemeters. For all workers, the annual mean Hp(3) was estimated to be 1.1 mSv (max. 3.9 mSv). The relation between Hp(3) to routinely monitored personal dose equivalent Hp(10) was clearly correlated. Considering individual dose measurement periods (2–4 weeks), the Hp(3)/Hp(10) ratio was 0.7 (Pearson’s coefficient r = 0.90, p < 0.001, variation of ratio 0.1–2.3). The variation decreased considerably with increasing Hp(10) (σ2 = 0.04 vs. 0.43 for Hp(10) > 0.1 mSv vs. < 0.1 mSv, respectively), i.e. higher Hp(10) predicts Hp(3) more reliably. Moreover, annual Hp(10) data from national dose register during 2009–2018 were used to derive the annual Hp(3) applying the Hp(3)/Hp(10) ratio. The data from Finnish nuclear medicine departments imply that routine measurements of Hp(3) among nuclear medicine technicians are not justified.
- 11 September 2014
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 164 (3) , 361-367
Validation of a MOSFET dosemeter system for determining the absorbed and effective radiation doses in diagnostic radiology
This study aimed to validate a MOSFET dosemeter system for determining absorbed and effective doses (EDs) in the dose and energy range used in diagnostic radiology. Energy dependence, dose linearity and repeatability of the dosemeter were examined. The absorbed doses (ADs) were compared at anterior–posterior projection and the EDs were determined at posterior–anterior, anterior–posterior and lateral projections of thoracic imaging using an anthropomorphic phantom. The radiation exposures were made using digital radiography systems. This study revealed that the MOSFET system with high sensitivity bias supply set-up is sufficiently accurate for AD and ED determination. The dosemeter is recommended to be calibrated for energies 80 kVp. The entrance skin dose level should be at least 5 mGy to minimise the deviation of the individual dosemeter dose. For ED determination, dosemeters should be implanted perpendicular to the surface of the phantom to prevent the angular dependence error.
- 11 September 2014
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 164 (3) , 361-367
Validation of a MOSFET dosemeter system for determining the absorbed and effective radiation doses in diagnostic radiology
This study aimed to validate a MOSFET dosemeter system for determining absorbed and effective doses (EDs) in the dose and energy range used in diagnostic radiology. Energy dependence, dose linearity and repeatability of the dosemeter were examined. The absorbed doses (ADs) were compared at anterior–posterior projection and the EDs were determined at posterior–anterior, anterior–posterior and lateral projections of thoracic imaging using an anthropomorphic phantom. The radiation exposures were made using digital radiography systems. This study revealed that the MOSFET system with high sensitivity bias supply set-up is sufficiently accurate for AD and ED determination. The dosemeter is recommended to be calibrated for energies 80 kVp. The entrance skin dose level should be at least 5 mGy to minimise the deviation of the individual dosemeter dose. For ED determination, dosemeters should be implanted perpendicular to the surface of the phantom to prevent the angular dependence error.
- 21 November 2013
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 37 (4) , 942-948
Fetal Radiation Dose in Prophylactic Uterine Arterial Embolization
The purpose of the study was to estimate the absorbed dose (AD) to the fetus for pregnant patients with placenta accreta undergoing fluoroscopy imaging during prophylactic catheterization and uterine artery embolization. We hypothesize that after optimizing the use of the radiation, this endovascular method is safe.
- 21 November 2013
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 37 (4) , 942-948
Fetal Radiation Dose in Prophylactic Uterine Arterial Embolization
The purpose of the study was to estimate the absorbed dose (AD) to the fetus for pregnant patients with placenta accreta undergoing fluoroscopy imaging during prophylactic catheterization and uterine artery embolization. We hypothesize that after optimizing the use of the radiation, this endovascular method is safe.
- Open Access
- 14 June 2012
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 33 (11) , 2038-2042
A Comparison of Radiation Exposure between Diagnostic CTA and DSA Examinations of Cerebral and Cervicocerebral Vessels
BACKGROUND AND PURPOSE: While the number of CTA examinations is continually increasing compared with DSA examinations, there is little comparative dose information about the different imaging techniques. We compared patient radiation exposure resulting from diagnostic CTA and DSA examinations for both cerebral and cervicocerebral vessels. MATERIALS AND METHODS: An anthropomorphic phantom was irradiated by using typical diagnostic CTA and DSA setups and imaging parameters. For both imaging techniques, the imaging area of cerebral vessels included intracranial vessels only, while the imaging area of cervicocerebral vessels included both cervical and intracranial vessels from the aortic arch to the vertex. The effective dose was determined by using RPLDs. The DSA examination was simulated by using a biplane angiography system, and the CTA examination, by using a 64-row multidetector CT scanner. RESULTS: For the imaging of cerebral vessels, the effective dose according to ICRP 103 was 0.67 mSv for CTA and 2.71 mSv for DSA. For the imaging of cervicocerebral vessels, the effective dose was 4.85 mSv for CTA and 3.60 mSv for DSA. The maximum absorbed dose (milligray) for skin, brain, salivary glands, and eyes was 166.2, 73.5, 35.6, and 21.8 mGy for DSA and 19.0, 16.9, 20.4, and 14.8 mGy for CTA, respectively. The conversion factors from DAP and DLP to effective dose were calculated. CONCLUSIONS: The effective dose for CTA assessment of cerebral vessels was approximately one-fifth the dose compared with DSA. In the imaging of cervicocerebral vessels, the effective dose for CTA was approximately one-third higher compared with DSA.
- 14 June 2012
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 33 (11) , 2038-2042
Open AccessA Comparison of Radiation Exposure between Diagnostic CTA and DSA Examinations of Cerebral and Cervicocerebral Vessels
BACKGROUND AND PURPOSE: While the number of CTA examinations is continually increasing compared with DSA examinations, there is little comparative dose information about the different imaging techniques. We compared patient radiation exposure resulting from diagnostic CTA and DSA examinations for both cerebral and cervicocerebral vessels. MATERIALS AND METHODS: An anthropomorphic phantom was irradiated by using typical diagnostic CTA and DSA setups and imaging parameters. For both imaging techniques, the imaging area of cerebral vessels included intracranial vessels only, while the imaging area of cervicocerebral vessels included both cervical and intracranial vessels from the aortic arch to the vertex. The effective dose was determined by using RPLDs. The DSA examination was simulated by using a biplane angiography system, and the CTA examination, by using a 64-row multidetector CT scanner. RESULTS: For the imaging of cerebral vessels, the effective dose according to ICRP 103 was 0.67 mSv for CTA and 2.71 mSv for DSA. For the imaging of cervicocerebral vessels, the effective dose was 4.85 mSv for CTA and 3.60 mSv for DSA. The maximum absorbed dose (milligray) for skin, brain, salivary glands, and eyes was 166.2, 73.5, 35.6, and 21.8 mGy for DSA and 19.0, 16.9, 20.4, and 14.8 mGy for CTA, respectively. The conversion factors from DAP and DLP to effective dose were calculated. CONCLUSIONS: The effective dose for CTA assessment of cerebral vessels was approximately one-fifth the dose compared with DSA. In the imaging of cervicocerebral vessels, the effective dose for CTA was approximately one-third higher compared with DSA.