Yann T. Delorme
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yann T. Delorme has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Kameswararao Anupindi
Indian Institute of Technology Madras
3 shared publications Steven H. Frankel
Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa, Israel
2 shared publicationsA.E. Kerlo
School of Mechanical Engineering, Purdue University, Lafayette, Ind
1 shared publicationAnna-Elodie M Kerlo
Purdue Univ, Sch Mech Engn, Lafayette, IN 47907 USA
1 shared publication- Chandra Shekhar Pant
Department of Hydro and Renewable Energy, Indian Institute of Technology Roorkee, Roorkee, India
1 shared publication D. Shetty
School of Mechanical Engineering, Purdue University, Lafayette, Ind
1 shared publication
Latest Publications
- Open Access
Accuracy Assessment of RANS Predictions of Active Flow Control for Hydrofoil Cavitation
In this work, we numerically investigate the cavitating flow on the scaled-down 2D model of guided vanes. Furthermore, the effects of wall injection on both the cavitation and on the hydrodynamic performance of the guided vane are studied. The numerical simulations are performed using OpenFOAM v1906. We used a 2D k- SST model for modeling the turbulence in the present set of simulations. We studied the flow for two angles of attack, viz. and . For the angle of attack, the present numerical work is in good agreement with the previous experimental work, but for the larger angle of attack, because of flow separation, the present simulations do not capture the flow correctly.Open AccessAccuracy Assessment of RANS Predictions of Active Flow Control for Hydrofoil Cavitation
In this work, we numerically investigate the cavitating flow on the scaled-down 2D model of guided vanes. Furthermore, the effects of wall injection on both the cavitation and on the hydrodynamic performance of the guided vane are studied. The numerical simulations are performed using OpenFOAM v1906. We used a 2D k- SST model for modeling the turbulence in the present set of simulations. We studied the flow for two angles of attack, viz. and . For the angle of attack, the present numerical work is in good agreement with the previous experimental work, but for the larger angle of attack, because of flow separation, the present simulations do not capture the flow correctly. - 9 November 2016
- Published by Elsevier in Computers & Fluids
- Vol. 143, 16-31
Multiblock high order Large Eddy Simulation of powered Fontan hemodynamics: Towards computational surgery
- 9 November 2016
- Published by Elsevier in Computers & Fluids
- Vol. 143, 16-31
Multiblock high order Large Eddy Simulation of powered Fontan hemodynamics: Towards computational surgery
- 17 July 2014
- Published by IOP Publishing in Fluid Dynamics Research
- Vol. 46 (4) , 041425
Dynamic mode decomposition of Fontan hemodynamics in an idealized total cavopulmonary connection
Univentricular heart disease is the leading cause of death from any birth defect in the first year of life. Typically, patients have to undergo three open heart surgical procedures within the first few years of their lives to eventually directly connect the superior and inferior vena cavae to the left and right pulmonary arteries forming the total cavopulmonary connection (TCPC). The end result is a weak circulation where the single working ventricle pumps oxygenated blood to the body and de-oxygenated blood flows passively through the TCPC into the lungs. The fluid dynamics of the TCPC junction involve confined impinging jets resulting in a highly unstable flow, significant mechanical energy dissipation and undesirable pressure loss. Understanding and predicting such flows is important for improving the surgical procedure and for the design of mechanical cavopulmonary assist devices. In this study, dynamic mode decomposition (DMD) is used to analyze previously obtained stereoscopic particle imaging velocimetry (SPIV) data and large eddy simulation (LES) results for an idealized TCPC. Analysis of the DMD modes from the SPIV and LES serves to both highlight the unsteady vortical dynamics and the qualitative agreement between measurements and simulations.
- 17 July 2014
- Published by IOP Publishing in Fluid Dynamics Research
- Vol. 46 (4) , 041425
Dynamic mode decomposition of Fontan hemodynamics in an idealized total cavopulmonary connection
Univentricular heart disease is the leading cause of death from any birth defect in the first year of life. Typically, patients have to undergo three open heart surgical procedures within the first few years of their lives to eventually directly connect the superior and inferior vena cavae to the left and right pulmonary arteries forming the total cavopulmonary connection (TCPC). The end result is a weak circulation where the single working ventricle pumps oxygenated blood to the body and de-oxygenated blood flows passively through the TCPC into the lungs. The fluid dynamics of the TCPC junction involve confined impinging jets resulting in a highly unstable flow, significant mechanical energy dissipation and undesirable pressure loss. Understanding and predicting such flows is important for improving the surgical procedure and for the design of mechanical cavopulmonary assist devices. In this study, dynamic mode decomposition (DMD) is used to analyze previously obtained stereoscopic particle imaging velocimetry (SPIV) data and large eddy simulation (LES) results for an idealized TCPC. Analysis of the DMD modes from the SPIV and LES serves to both highlight the unsteady vortical dynamics and the qualitative agreement between measurements and simulations.
- 3 July 2013
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 4 (4) , 392-407
Large Eddy Simulation of FDA’s Idealized Medical Device
A hybrid large eddy simulation and immersed boundary method (IBM) computational approach is used to make quantitative predictions of flow field statistics within the Food and Drug Administration’s idealized medical device. An in-house code is used, hereafter (WenoHemo™), that combines high-order finite-difference schemes on structured staggered Cartesian grids with an IBM to facilitate flow over or through complex stationary or rotating geometries and employs a subgrid-scale turbulence model that more naturally handles transitional flows (Delorme et al., J Biomech 46:207–436, 2013). Predictions of velocity and wall shear stress statistics are compared with previously published experimental measurements from Hariharan et al. (J Biomech Eng 133:041002, 2011) for the four Reynolds numbers considered.
- 3 July 2013
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 4 (4) , 392-407
Large Eddy Simulation of FDA’s Idealized Medical Device
A hybrid large eddy simulation and immersed boundary method (IBM) computational approach is used to make quantitative predictions of flow field statistics within the Food and Drug Administration’s idealized medical device. An in-house code is used, hereafter (WenoHemo™), that combines high-order finite-difference schemes on structured staggered Cartesian grids with an IBM to facilitate flow over or through complex stationary or rotating geometries and employs a subgrid-scale turbulence model that more naturally handles transitional flows (Delorme et al., J Biomech 46:207–436, 2013). Predictions of velocity and wall shear stress statistics are compared with previously published experimental measurements from Hariharan et al. (J Biomech Eng 133:041002, 2011) for the four Reynolds numbers considered.
- 1 January 2013
- Published by Elsevier in Journal of Biomechanics
- Vol. 46 (2) , 408-422
Large eddy simulation of powered Fontan hemodynamics
- 1 January 2013
- Published by Elsevier in Journal of Biomechanics
- Vol. 46 (2) , 408-422
Large eddy simulation of powered Fontan hemodynamics