TBThomas P. Burg

Thomas P. Burg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thomas P. Burg has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Robust Smartphone Assisted Biosensing Based on Asymmetric Nanofluidic Grating Interferometry

    by Foelke Purr, Max-Frederik Eckardt, Jonas Kieserling, Paul-Luis Gronwald, Thomas P. Burg, Andreas Dietzel

    Point-of-care systems enable fast therapy decisions on site without the need of any healthcare infrastructure. In addition to the sensitive detection, stable measurement by inexperienced persons outside of laboratory facilities is indispensable. A particular challenge in field applications is to reduce interference from environmental factors, such as temperature, to acceptable levels without sacrificing simplicity. Here, we present a smartphone-based point-of-care sensor. The method uses an optofluidic grating composed of alternating detection and reference channels arranged as a reflective phase grating. Biomolecules adsorbing to the detection channel alter the optical path length, while the parallel reference channels enable a direct common mode rejection within a single measurement. The optical setup is integrated in a compact design of a mobile readout device and the usability is ensured by a smartphone application. Our results show that different ambient temperatures do not have any influence on the signal. In a proof-of concept experiment we measured the accumulation of specific molecules in functionalized detection channels in real-time and without the need of any labeling. Therefore, the channel walls have been modified with biotin as capture molecules and the specific binding of streptavidin was detected. A mobile, reliable and robust point-of-care device has been realized by combining an inherently differential measurement concept with a smartphone-based, mobile readout device.


  • Open Access

    A Microfluidic Split-Flow Technology for Product Characterization in Continuous Low-Volume Nanoparticle Synthesis

    by Holger Bolze, Peer Erfle, Juliane Riewe, Heike Bunjes, Andreas Dietzel, Thomas P. Burg

    A key aspect of microfluidic processes is their ability to perform chemical reactions in small volumes under continuous flow. However, a continuous process requires stable reagent flow over a prolonged period. This can be challenging in microfluidic systems, as bubbles or particles easily block or alter the flow. Online analysis of the product stream can alleviate this problem by providing a feedback signal. When this signal exceeds a pre-defined range, the process can be re-adjusted or interrupted to prevent contamination. Here we demonstrate the feasibility of this concept by implementing a microfluidic detector downstream of a segmented-flow system for the synthesis of lipid nanoparticles. To match the flow rate through the detector to the measurement bandwidth independent of the synthesis requirements, a small stream is sidelined from the original product stream and routed through a measuring channel with 2 × 2 µm cross-section. The small size of the measuring channel prevents the entry of air plugs, which are inherent to our segmented flow synthesis device. Nanoparticles passing through the small channel were detected and characterized by quantitative fluorescence measurements. With this setup, we were able to count single nanoparticles. This way, we were able to detect changes in the particle synthesis affecting the size, concentration, or velocity of the particles in suspension. We envision that the flow-splitting scheme demonstrated here can be transferred to detection methods other than fluorescence for continuous monitoring and feedback control of microfluidic nanoparticle synthesis.


  • Open Access

    Determination of the refractive index of liquids at cryogenic temperature

    by R. Faoro, M. Bassu, T. P. Burg

    In this work, we present a method for measuring the refractive index of liquids at cryogenic temperature by shearing interferometry. The method is self-calibrated and easy to use over the range from cryogenic to room temperature. We validated the accuracy of our approach by comparing the measured refractive index of liquid propane with data reported in the literature. Moreover, we measured the refractive indices of three as yet uncharacterized fluorinated liquids that are of great interest as immersion fluids in the field of cryogenic light microscopy.


  • Open Access

    Cryofixation during live‐imaging enables millisecond time‐correlated light and electron microscopy

    by M. Fuest, G. M. Nocera, M. M. Modena, D. Riedel, Y. X. Mejia, T. P. Burg

    Summary: Correlating live‐cell imaging with electron microscopy is among the most promising approaches to relate dynamic functions of cells or small organisms to their underlying ultrastructure. The time correlation between light and electron micrographs, however, is limited by the sample handling and fixation required for electron microscopy. Current cryofixation methods require a sample transfer step from the light microscope to a dedicated instrument for cryofixation. This transfer step introduces a time lapse of one second or more between live imaging and the fixed state, which is studied by electron microscopy. In this work, we cryofix Caenorhabditis elegans directly within the light microscope field of view, enabling millisecond time‐correlated live imaging and electron microscopy. With our approach, the time‐correlation is limited only by the sample cooling rate. C. elegans was used as a model system to establish compatibility of in situ cryofixation and subsequent transmission electron microscopy (TEM). TEM images of in situ cryofixed C. elegans show that the ultrastructure of the sample was well preserved with this method. We expect that the ability to correlate live imaging and electron microscopy at the millisecond scale will enable new paradigms to study biological processes across length scales based on real‐time selection and arrest of a desired state.Lay Description: Researchers seek to link cellular functions to their smallest structural components. Currently this requires correlation of two imaging techniques, live imaging and electron microscopy. Current correlative methods, however, have limited time resolution due to the sample preparation procedures for electron microscopy. Following live imaging, samples are transferred from the light microscope to a cryofixation, or ultra‐fast freezing, instrument. The biological process progresses until the sample freezes, 1 second or more after the last live image. In this work, samples are cryofixed directly within the light microscope field of view. By eliminating the transfer step, time correlation between light and electron microscopy images of our samples is limited only by the freezing rate to the order of milliseconds rather than seconds.


  • Open Access

    Aberration-corrected cryoimmersion light microscopy

    by Raffaele Faoro, Margherita Bassu, Yara X. Mejia, Till Stephan, Nikunj Dudani, Christian Boeker, Stefan Jakobs, Thomas P. Burg

    Cryogenic fluorescent light microscopy of flash-frozen cells stands out by artifact-free fixation and very little photobleaching of the fluorophores used. To attain the highest level of resolution, aberration-free immersion objectives with accurately matched immersion media are required, but both do not exist for imaging below the glass-transition temperature of water. Here, we resolve this challenge by combining a cryoimmersion medium, HFE-7200, which matches the refractive index of room-temperature water, with a technological concept in which the body of the objective and the front lens are not in thermal equilibrium. We implemented this concept by replacing the metallic front-lens mount of a standard bioimaging water immersion objective with an insulating ceramic mount heated around its perimeter. In this way, the objective metal housing can be maintained at room temperature, while creating a thermally shielded cold microenvironment around the sample and front lens. To demonstrate the range of potential applications, we show that our method can provide superior contrast in Escherichia coli and yeast cells expressing fluorescent proteins and resolve submicrometer structures in multicolor immunolabeled human bone osteosarcoma epithelial (U2OS) cells at −140°C. Significance Cryofluorescence imaging is of great interest in biological microscopy because vitrified samples (i.e., frozen without ice crystallization) are free from fixation artifacts, are highly photostable, and allow direct correlation with electron cryomicroscopy. Here, we show a concept for conducting cryo-light microscopy in immersion that provides a twofold to fivefold increase in image brightness and higher resolution than are attainable with air objectives. Spherical aberration at an imaging temperature below the glass transition of water (−135 °C) is corrected by our approach.


  • Open Access

    Asymmetric nanofluidic grating detector for differential refractive index measurement and biosensing

    by F. Purr, M. Bassu, R. D. Lowe, B. Thürmann, A. Dietzel, T. P. Burg

    Measuring small changes in refractive index can provide both sensitive and contactless information on molecule concentration or process conditions for a wide range of applications. However, refractive index measurements are easily perturbed by non-specific background signals, such as temperature changes or non-specific binding. Here, we present an optofluidic device for measuring refractive index with direct background subtraction within a single measurement. The device is comprised of two interdigitated arrays of nanofluidic channels designed to form an optical grating. Optical path differences between the two sets of channels can be measured directly via an intensity ratio within the diffraction pattern that forms when the grating is illuminated by a collimated laser beam. Our results show that no calibration or biasing is required if the unit cell of the grating is designed with an appropriate built-in asymmetry. In proof-of-concept experiments we attained a noise level equivalent to ∼10−5 refractive index units (30 Hz sampling rate, 4 min measurement interval). Furthermore, we show that the accumulation of biomolecules on the surface of the nanochannels can be measured in real-time. Because of its simplicity and robustness, we expect that this inherently differential measurement concept will find many applications in ultra-low volume analytical systems, biosensors, and portable devices.


  • Continuous high throughput nanofluidic separation through tangential-flow vertical nanoslit arrays

    by Margherita Bassu, Peter Holik, Sam Schmitz, Siegfried Steltenkamp, Thomas P. Burg

    We describe the fabrication of ultra uniform nanoslit arrays and their application to continuous separation of small molecules by charge.


  • Microfluidic cryofixation for correlative microscopy

    by Yara X. Mejia, Holger Feindt, Dongfeng Zhang, Siegfried Steltenkamp, Thomas P. Burg

    Microfluidic approach that enables cryofixation to be performed directly in the light microscope with millisecond time resolution and at atmospheric pressure.


  • Resolution enhancement of suspended microchannel resonators for weighing of biomolecular complexes in solution

    by Mario M. Modena, Yu Wang, Dietmar Riedel, Thomas P. Burg

    We introduce the use of correlation analysis to extend the dynamic range of suspended micro- and nanochannel resonator (SMR/SNR) mass sensors by over five orders of magnitude. This method can analyze populations of particles flowing through an embedded channel micromechanical resonator, even when the individual particle masses are far below the noise floor. To characterize the method, we measured the mass of polystyrene nanoparticles with 300 zg resolution. As an application, we monitored the time course of insulin amyloid formation from pre-fibrillar aggregates to mature fibrils of 15 MDa average mass. Results were compared with thioflavin-T (ThT) assays and electron microscopy (EM). Mass measurements offer additional information over ThT during the fluorescent inaccessible lag period, and the average fibril dimensions calculated from the mass signal are in good accordance with EM. In the future, we envision that more detailed modeling will allow the computational deconvolution of multicomponent samples, enabling the mass spectrometric characterization of a variety of biomolecular complexes, small organelles, and nanoparticles in solution.