Tao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tao Zhang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
John M. Pauly
Department of Electrical Engineering, Magnetic Resonance Systems Research Laboratory Stanford University Stanford California USA
3 shared publicationsMarcus T. Alley
Radiology Stanford University Stanford California USA
2 shared publicationsMichael Lustig
Electrical Engineering and Computer Sciences University of California Berkeley California USA
2 shared publicationsRichard A. Barth
Radiology Stanford University Stanford California USA
2 shared publications- Shreyas S. Vasanawala
Department of Radiology Stanford University Stanford California USA
2 shared publications Aaron G. Potnick
Radiology Stanford University Stanford California USA
1 shared publication
Latest Publications
- Open Access
- 5 February 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (2) , 655-661
Accelerating parameter mapping with a locally low rank constraint
Purpose: To accelerate MR parameter mapping using a locally low rank (LLR) constraint, and the combination of parallel imaging and the LLR constraint.Theory and Methods: An LLR method is developed for MR parameter mapping and compared with a globally low rank method in a multiecho spin‐echo T2 mapping experiment. For acquisition with coil arrays, a combined LLR and parallel imaging method is proposed. The proposed method is evaluated in a variable flip angle T1 mapping experiment and compared with the LLR method and parallel imaging alone.Results: In the multiecho spin‐echo T2 mapping experiment, the LLR method is more accurate than the globally low rank method for acceleration factors 2 and 3, especially for tissues with high T2 values. Variable flip angle T1 mapping is achieved by acquiring datasets with 10 flip angles, each dataset accelerated by a factor of 6, and reconstructed by the proposed method with a small normalized root mean square error of 0.025.Conclusions: The LLR method is likely superior to the globally low rank method for MR parameter mapping. The proposed combined LLR and parallel imaging method has better performance than the two methods alone, especially with highly accelerated acquisition. Magn Reson Med 73:655–661, 2015. © 2014 Wiley Periodicals, Inc.
- 5 February 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (2) , 655-661
Open AccessAccelerating parameter mapping with a locally low rank constraint
Purpose: To accelerate MR parameter mapping using a locally low rank (LLR) constraint, and the combination of parallel imaging and the LLR constraint.Theory and Methods: An LLR method is developed for MR parameter mapping and compared with a globally low rank method in a multiecho spin‐echo T2 mapping experiment. For acquisition with coil arrays, a combined LLR and parallel imaging method is proposed. The proposed method is evaluated in a variable flip angle T1 mapping experiment and compared with the LLR method and parallel imaging alone.Results: In the multiecho spin‐echo T2 mapping experiment, the LLR method is more accurate than the globally low rank method for acceleration factors 2 and 3, especially for tissues with high T2 values. Variable flip angle T1 mapping is achieved by acquiring datasets with 10 flip angles, each dataset accelerated by a factor of 6, and reconstructed by the proposed method with a small normalized root mean square error of 0.025.Conclusions: The LLR method is likely superior to the globally low rank method for MR parameter mapping. The proposed combined LLR and parallel imaging method has better performance than the two methods alone, especially with highly accelerated acquisition. Magn Reson Med 73:655–661, 2015. © 2014 Wiley Periodicals, Inc.
- Open Access
- 21 December 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 41 (2) , 460-473
Fast pediatric 3D free‐breathing abdominal dynamic contrast enhanced MRI with high spatiotemporal resolution
Purpose: To develop a method for fast pediatric 3D free‐breathing abdominal dynamic contrast enhanced (DCE) magnetic resonance imaging (MRI) and investigate its clinical feasibility.Materials and Methods: A combined locally low rank parallel imaging method with soft gating is proposed for free‐breathing DCE MRI acquisition. With Institutional Review Board (IRB) approval and informed consent/assent, 23 consecutive pediatric patients were recruited for this study. Free‐breathing DCE MRI with ∼1 mm3 spatial resolution and a 6.5‐sec frame rate was acquired on a 3T scanner. Undersampled data were reconstructed with a compressed sensing method without motion correction (FB‐CS) and the proposed method (FB‐LR). A follow‐up respiratory‐triggered acquisition (RT‐CS) was performed as a reference standard. The reconstructed images were evaluated independently by two radiologists. Wilcoxon tests were performed to test the hypothesis that there was no significant difference between different reconstructions. Quantitative evaluation of contrast dynamics was also performed.Results: The mean score of overall image quality of FB‐LR was 4.0 on a 5‐point scale, significantly better (P < 0.05) than FB‐CS reconstruction (mean score 2.9), and similar to RT‐CS (mean score 4.1). FB‐LR also matched the temporal fidelity of contrast dynamics with a root mean square error less than 5%.Conclusion: Fast 3D free‐breathing DCE MRI with high scan efficiency and image quality similar to respiratory‐triggered acquisition is feasible in a pediatric clinical setting. J. Magn. Reson. Imaging 2015;41:460–473.© 2013 Wiley Periodicals, Inc.
- 21 December 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 41 (2) , 460-473
Open AccessFast pediatric 3D free‐breathing abdominal dynamic contrast enhanced MRI with high spatiotemporal resolution
Purpose: To develop a method for fast pediatric 3D free‐breathing abdominal dynamic contrast enhanced (DCE) magnetic resonance imaging (MRI) and investigate its clinical feasibility.Materials and Methods: A combined locally low rank parallel imaging method with soft gating is proposed for free‐breathing DCE MRI acquisition. With Institutional Review Board (IRB) approval and informed consent/assent, 23 consecutive pediatric patients were recruited for this study. Free‐breathing DCE MRI with ∼1 mm3 spatial resolution and a 6.5‐sec frame rate was acquired on a 3T scanner. Undersampled data were reconstructed with a compressed sensing method without motion correction (FB‐CS) and the proposed method (FB‐LR). A follow‐up respiratory‐triggered acquisition (RT‐CS) was performed as a reference standard. The reconstructed images were evaluated independently by two radiologists. Wilcoxon tests were performed to test the hypothesis that there was no significant difference between different reconstructions. Quantitative evaluation of contrast dynamics was also performed.Results: The mean score of overall image quality of FB‐LR was 4.0 on a 5‐point scale, significantly better (P < 0.05) than FB‐CS reconstruction (mean score 2.9), and similar to RT‐CS (mean score 4.1). FB‐LR also matched the temporal fidelity of contrast dynamics with a root mean square error less than 5%.Conclusion: Fast 3D free‐breathing DCE MRI with high scan efficiency and image quality similar to respiratory‐triggered acquisition is feasible in a pediatric clinical setting. J. Magn. Reson. Imaging 2015;41:460–473.© 2013 Wiley Periodicals, Inc.
- Open Access
- 11 October 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 40 (1) , 13-25
Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction
Purpose: To deploy clinically, a combined parallel imaging compressed sensing method with coil compression that achieves a rapid image reconstruction, and assess its clinical performance in contrast‐enhanced abdominal pediatric MRI.Materials and Methods: With Institutional Review Board approval and informed patient consent/assent, 29 consecutive pediatric patients were recruited. Dynamic contrast‐enhanced MRI was acquired on a 3 Tesla scanner using a dedicated 32‐channel pediatric coil and a three‐dimensional SPGR sequence, with pseudo‐random undersampling at a high acceleration (R = 7.2). Undersampled data were reconstructed with three methods: a traditional parallel imaging method and a combined parallel imaging compressed sensing method with and without coil compression. The three sets of images were evaluated independently and blindly by two radiologists at one siting, for overall image quality and delineation of anatomical structures. Wilcoxon tests were performed to test the hypothesis that there was no significant difference in the evaluations, and interobserver agreement was analyzed.Results: Fast reconstruction with coil compression did not deteriorate image quality. The mean score of structural delineation of the fast reconstruction was 4.1 on a 5‐point scale, significantly better (P < 0.05) than traditional parallel imaging (mean score 3.1). Fair to substantial interobserver agreement was reached in structural delineation assessment.Conclusion: A fast combined parallel imaging compressed sensing method is feasible in a pediatric clinical setting. Preliminary results suggest it may improve structural delineation over parallel imaging. J. Magn. Reson. Imaging 2014;40:13–25. © 2013 Wiley Periodicals, Inc.
- 11 October 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 40 (1) , 13-25
Open AccessClinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction
Purpose: To deploy clinically, a combined parallel imaging compressed sensing method with coil compression that achieves a rapid image reconstruction, and assess its clinical performance in contrast‐enhanced abdominal pediatric MRI.Materials and Methods: With Institutional Review Board approval and informed patient consent/assent, 29 consecutive pediatric patients were recruited. Dynamic contrast‐enhanced MRI was acquired on a 3 Tesla scanner using a dedicated 32‐channel pediatric coil and a three‐dimensional SPGR sequence, with pseudo‐random undersampling at a high acceleration (R = 7.2). Undersampled data were reconstructed with three methods: a traditional parallel imaging method and a combined parallel imaging compressed sensing method with and without coil compression. The three sets of images were evaluated independently and blindly by two radiologists at one siting, for overall image quality and delineation of anatomical structures. Wilcoxon tests were performed to test the hypothesis that there was no significant difference in the evaluations, and interobserver agreement was analyzed.Results: Fast reconstruction with coil compression did not deteriorate image quality. The mean score of structural delineation of the fast reconstruction was 4.1 on a 5‐point scale, significantly better (P < 0.05) than traditional parallel imaging (mean score 3.1). Fair to substantial interobserver agreement was reached in structural delineation assessment.Conclusion: A fast combined parallel imaging compressed sensing method is feasible in a pediatric clinical setting. Preliminary results suggest it may improve structural delineation over parallel imaging. J. Magn. Reson. Imaging 2014;40:13–25. © 2013 Wiley Periodicals, Inc.