Latest Publications

  • Open Access

    Wideband arrhythmia‐Insensitive‐rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by an implantable‐cardioverter‐defibrillator

    by KyungPyo Hong, Eun‐Kee Jeong, T. Scott Wall, Stavros G. Drakos, Daniel Kim

    Purpose: To develop and evaluate a wideband arrhythmia‐insensitive‐rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by implantable‐cardioverter‐defibrillator (ICD).Methods: We developed a wideband AIR pulse sequence by incorporating a saturation pulse with wide frequency bandwidth (8.9 kHz) to achieve uniform T1 weighting in the heart with ICD. We tested the performance of original and “wideband” AIR cardiac T1 mapping pulse sequences in phantom and human experiments at 1.5 Tesla.Results: In five phantoms representing native myocardium and blood and postcontrast blood/tissue T1 values, compared with the control T1 values measured with an inversion‐recovery pulse sequence without ICD, T1 values measured with original AIR with ICD were considerably lower (absolute percent error > 29%), whereas T1 values measured with wideband AIR with ICD were similar (absolute percent error < 5%). Similarly, in 11 human subjects, compared with the control T1 values measured with original AIR without ICD, T1 measured with original AIR with ICD was significantly lower (absolute percent error > 10.1%), whereas T1 measured with wideband AIR with ICD was similar (absolute percent error < 2.0%).Conclusion: This study demonstrates the feasibility of a wideband pulse sequence for cardiac T1 mapping without significant image artifacts induced by ICD. Magn Reson Med 74:336–345, 2015.


  • MOLLI and AIR T1 mapping pulse sequences yield different myocardial T1 and ECV measurements

    by KyungPyo Hong, Daniel Kim

    Both post‐contrast myocardial T1 and extracellular volume (ECV) have been reported to be associated with diffuse interstitial fibrosis. Recently, the cardiovascular magnetic resonance (CMR) field is recognizing that post‐contrast myocardial T1 is sensitive to several confounders and migrating towards ECV as a measure of collagen volume fraction. Several recent studies using widely available Modified Look‐Locker Inversion‐recovery (MOLLI) have reported ECV cutoff values to distinguish between normal and diseased myocardium. It is unclear if these cutoff values are translatable to different T1 mapping pulse sequences such as arrhythmia‐insensitive‐rapid (AIR) cardiac T1 mapping, which was recently developed to rapidly image patients with cardiac rhythm disorders. We sought to evaluate, in well‐controlled canine and pig experiments, the relative accuracy and precision, as well as intra‐ and inter‐observer variability in data analysis, of ECV measured with AIR as compared with MOLLI.In 16 dogs, as expected, the mean T1 was significantly different (p < 0.001) between MOLLI (891 ± 373 ms) and AIR (1071 ± 503 ms), but, surprisingly, the mean ECV between MOLLI (21.8 ± 2.1%) and AIR (19.6 ± 2.4%) was also significantly different (p < 0.001). Both intra‐ and inter‐observer agreements in T1 calculations were higher for MOLLI than AIR, but intra‐ and inter‐observer agreements in ECV calculations were similar between MOLLI and AIR. In six pigs, the coefficient of repeatability (CR), as defined by the Bland–Altman analysis, in T1 calculation was considerably lower for MOLLI (32.5 ms) than AIR (82.3 ms), and the CR in ECV calculation was also lower for MOLLI (1.8%) than AIR (4.5%).In conclusion, this study shows that MOLLI and AIR yield significantly different T1 and ECV values in large animals and that MOLLI yields higher precision than AIR. Findings from this study suggest that CMR researchers must consider the specific pulse sequence when translating published ECV cutoff values into their own studies. Copyright © 2014 John Wiley & Sons, Ltd.


  • Quadruple inversion-recovery b-SSFP MRA of the abdomen: Initial clinical validation

    by Iliyana P. Atanasova, Ruth P. Lim, Hersh Chandarana, Pippa Storey, Mary T. Bruno, Daniel Kim, Vivian S. Lee


  • Post‐contrast myocardial T1 and ECV disagree in a longitudinal canine study

    by Matthias Koopmann, KyungPyo Hong, Eugene G. Kholmovski, Eric C. Huang, Nan Hu, Jian Ying, Richard Levenson, Sathya Vijayakumar, Derek J. Dosdall, Ravi Ranjan, et al.

    Both post‐contrast myocardial T1 and extracellular volume (ECV) measurements have been associated with diffuse interstitial fibrosis. The cardiovascular magnetic resonance (CMR) field is migrating towards ECV, because it is largely insensitive to confounders that affect post‐contrast myocardial T1. Despite the theoretical advantages of myocardial ECV over post‐contrast myocardial T1, systematic experimental studies comparing the two measurements are largely lacking. We sought to measure the temporal changes in post‐contrast myocardial T1 and ECV in an established canine model with chronic atrial fibrillation.Seventeen mongrel dogs, implanted with a pacemaker to induce chronic atrial fibrillation via rapid atrial pacing, were scanned multiple times for a total of 46 CMR scans at 3T. These dogs with different disease durations (0–22 months) were part of a separate longitudinal study aimed at studying the relationship between AF and pathophysiology. In each animal, we measured native and post‐contrast T1 values and hematocrit. Temporal changes in post‐contrast myocardial T1 and ECV, as well as other CMR parameters, were modeled with linear mixed effect models to account for repeated measurements over disease duration.In 17 animals, post‐contrast myocardial T1 decreased significantly from 872 to 698 ms (p < 0.001), which corresponds to a 24.9% relative reduction. In contrast, ECV increased from 21.0 to 22.0% (p = 0.38), which corresponds to only a 4.5% relative increase. To partially investigate this discrepancy, we quantified collagen volume fraction (CVF) in post‐mortem heart tissues of six canines sacrificed at different disease durations (0–22 months). CVF quantified by histology increased from 0.9 to 1.9% (p = 0.56), which agrees better with ECV than with post‐contrast myocardial T1. This study shows that post‐contrast myocardial T1 and ECV may disagree in a longitudinal canine study. A more comprehensive study, including histologic, cardiac, and renal functional analyses, is warranted to test rigorously which CMR parameter (ECV or post‐contrast myocardial T1) agrees better with CVF. Copyright © 2014 John Wiley & Sons, Ltd.


  • Evaluation of highly accelerated real‐time cardiac cine MRI in tachycardia

    by Elwin C. Bassett, Eugene G. Kholmovski, Brent D. Wilson, Edward V. R. DiBella, Derek J. Dosdall, Ravi Ranjan, Christopher J. McGann, Daniel Kim

    Electrocardiogram (ECG)‐gated breath‐hold cine MRI is considered to be the gold standard test for the assessment of cardiac function. However, it may fail in patients with arrhythmia, impaired breath‐hold capacity and poor ECG gating. Although ungated real‐time cine MRI may mitigate these problems, commercially available real‐time cine MRI pulse sequences using parallel imaging typically yield relatively poor spatiotemporal resolution because of their low image acquisition efficiency. As an extension of our previous work, the purpose of this study was to evaluate the diagnostic quality and accuracy of eight‐fold‐accelerated real‐time cine MRI with compressed sensing (CS) for the quantification of cardiac function in tachycardia, where it is challenging for real‐time cine MRI to provide sufficient spatiotemporal resolution. We evaluated the performances of eight‐fold‐accelerated cine MRI with CS, three‐fold‐accelerated real‐time cine MRI with temporal generalized autocalibrating partially parallel acquisitions (TGRAPPA) and ECG‐gated breath‐hold cine MRI in 21 large animals with tachycardia (mean heart rate, 104 beats per minute) at 3T. For each cine MRI method, two expert readers evaluated the diagnostic quality in four categories (image quality, temporal fidelity of wall motion, artifacts and apparent noise) using a Likert scale (1–5, worst to best). One reader evaluated the left ventricular functional parameters. The diagnostic quality scores were significantly different between the three cine pulse sequences, except for the artifact level between CS and TGRAPPA real‐time cine MRI. Both ECG‐gated breath‐hold cine MRI and eight‐fold accelerated real‐time cine MRI yielded all four scores of ≥ 3.0 (acceptable), whereas three‐fold‐accelerated real‐time cine MRI yielded all scores below 3.0, except for artifact (3.0). The left ventricular ejection fraction (LVEF) measurements agreed better between ECG‐gated cine MRI and eight‐fold‐accelerated real‐time cine MRI (mean difference, –1.6%) than between ECG‐gated cine MRI and three‐fold‐accelerated real‐time cine MRI (mean difference, –5.7%). Eight‐fold‐accelerated real‐time cine MRI with CS yields acceptable diagnostic quality and relatively accurate LVEF measurements in the challenging setting of tachycardia. Copyright © 2013 John Wiley & Sons, Ltd.


  • Open Access

    Rapid ungated myocardial perfusion cardiovascular magnetic resonance: preliminary diagnostic accuracy

    by Alexis Harrison, Ganesh Adluru, Kavitha Damal, Akram M Shaaban, Brent Wilson, Daniel Kim, Chris McGann, Nassir F Marrouche, Edward V R DiBella


  • Open Access

    Arrhythmia insensitive rapid cardiac T1 mapping pulse sequence

    by Michelle Fitts, Elodie Breton, Eugene G. Kholmovski, Derek J. Dosdall, Sathya Vijayakumar, Kyung P. Hong, Ravi Ranjan, Nassir F. Marrouche, Leon Axel, Daniel Kim

    Purpose: To develop an arrhythmia‐insensitive rapid (AIR) cardiac T1 mapping pulse sequence for quantification of diffuse fibrosis.Methods: An arrhythmia‐insensitive cardiac T1 mapping pulse sequence was developed based on saturation recovery T1 weighting, which is inherently insensitive to heart rate and rhythm, and two single‐shot balanced steady‐state free precession image acquisitions with centric k‐space ordering, where T1 calculation is inherently insensitive to T2 effects. Its performance against conventional cardiac T1 mapping based on inversion recovery (i.e., MOLLI) is compared. Phantom experiments (T1 ranging from 535 to 2123 ms) were performed with heart rate and rhythm simulated at 60 and 120 beats per minute (bpm) and arrhythmia using an external triggering device. Ten human subjects and 17 large animals were scanned precontrast and 5, 10, and 15 min after contrast agent administration.Results: Compared with the reference T1 mapping, AIR yielded lower normalized root‐mean‐square error than MOLLI (8% vs. 3%, respectively, at 60 bpm, 28% vs. 3%, respectively, at 120 bpm, and 22% vs. 3%, respectively, at arrhythmia). In vivo studies showed that T1 measurements made by MOLLI and AIR were strongly correlated (r = 0.99) but in poor agreement (mean difference = 161.8 ms, upper and lower 95% limits of agreements = 347.5 ms and −24.0 ms).Conclusion: Our AIR pulse sequence may be clinically useful for assessment of diffuse myocardial fibrosis in patients. Magn Reson Med 70:1274–1282, 2013.